Configuring basic DCE side frame relay

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter interface view.

interface interface-type interface-number

N/A

3. Enable frame relay on the interface.

link-protocol fr [ ietf | nonstandard ]

The default link layer protocol on a WAN interface is PPP. If frame relay is enabled with no operating mode specified, the IETF standard applies.

4. Configure the frame relay interface type as DCE or NNI.

fr interface-type { dce | nni }

The default setting is DTE.

5. Configure the frame relay LMI protocol type.

fr lmi type { ansi | nonstandard | q933a }

Optional.

The default setting is q933a.

6. Configure network side N392.

fr lmi n392dce n392-value

Optional.

The default setting is 3.

7. Configure network side N393.

fr lmi n393dce n393-value

Optional.

The default setting is 4.

8. Configure network side T392.

fr lmi t392dce t392-value

Optional.

The default setting is 15 seconds.