show environment temperature
Syntax
show environment temperature [detail] [vsf | vsx-peer]
Description
Shows the temperature information from sensors in the switch that affect fan control.
Command context
Operator (>
) or Manager (#
)
Parameters
detail
Shows detailed information from each temperature sensor.
vsf
Shows output from the VSF member-id on switches that support VSF.
[vsx-peer]
Shows the output from the VSX peer switch. If the switches do not have the VSX configuration or the ISL is down, the output from the VSX peer switch is not displayed. This parameter is available on switches that support VSX.
Authority
Operators or Administrators or local user group members with execution rights for this command. Operators can execute this command from the operator context (>) only.
Usage
Temperatures are shown in Celsius.
Valid values for status are the following:
normal
Sensor is within nominal temperature range.
min
Lowest temperature from this sensor.
max
Highest temperature from this sensor.
low_critical
Lowest threshold temperature for this sensor.
critical
Highest threshold temperature for this sensor.
fault
Fault event for this sensor.
emergency
Over temperature event for this sensor.
Examples
switch# show environment temperature Temperature information ------------------------------------------------------------------------------ Current Mbr/Slot-Sensor Module Type temperature Status ------------------------------------------------------------------------------ 1/1-PHY-01-08 line-card-module 51.00 C normal 1/1-PHY-09-16 line-card-module 48.00 C normal 1/1-PHY-17-24 line-card-module 50.00 C normal 1/1-PHY-25-32 line-card-module 52.00 C normal 1/1-PHY-33-40 line-card-module 53.00 C normal 1/1-PHY-41-48 line-card-module 54.00 C normal 1/1-Switch-ASIC-Internal line-card-module 63.25 C normal 1/1-CPU management-module 47.56 C normal 1/1-CPU-Zone-0 management-module 46.00 C normal 1/1-CPU-Zone-1 management-module 46.00 C normal 1/1-CPU-Zone-2 management-module 46.00 C normal 1/1-CPU-Zone-3 management-module 47.00 C normal 1/1-CPU-Zone-4 management-module 47.00 C normal 1/1-DDR management-module 37.75 C normal 1/1-DDR-Inlet management-module 30.69 C normal 1/1-Inlet-Air management-module 22.00 C normal 1/1-Switch-ASIC-Remote management-module 64.06 C normal