erps ring <ringid> hold-off-interval
Syntax
erps ring <ringid>
hold-off-interval <100 milliseconds>
Description
Specifies hold-off interval in units of 100 ms. If specified, a defect is not reported immediately. Instead, the hold-off timer is started. On expiration of the timer, if the defect still exists, it is reported to protection switching. The default value for hold-off timer is 0.
The
no
form of this command removes the configured value of the hold-off interval and sets it to the default value of 0.
Command context
config-erps-ring-<ringid>
Parameters
<ringid>
Required, specifies the ID of the ring. Range: 1-239
<100 milliseconds>
Required, specifies the hold-off interval in units of 100 ms. Default: 0.
Authority
Administrators or local user group members with execution rights for this command.
Examples
Specify the hold-off interval:
switch(config)# erps ring 3 switch(config-erps-ring-3)# hold-off-interval 100
Remove the configured value of the hold-off interval and set it to the default value of 0:
switch(config)# erps ring 3 switch(config-erps-ring-3)# no hold-off-interval