show diagnostic
Syntax
show diagnostic [{fabric | fan | module} [<MEMBER/SLOT>]} | rear-display-module]
[brief | detail] [vsx-peer]
Description
Displays the diagnostic test results for all modules or for a specified module.
Command context
Manager (#
)
Parameters
[fabric | fan | module]
Selects the options for showing diagnostic test results for a specific module.
fabric
Shows the diagnostic test results for a fabric module.
fan
Shows the diagnostic test results for a fan tray.
module
Shows the diagnostic test results for a management or line module.
<MEMBER/SLOT>
Specifies the slot number for management modules (1/5 or 1/6), line modules (1/1-1/4, 1/7-1/10), fan modules (1/1-1/3), and fabric modules(1/1-1/3).
rear-display-module
Shows the diagnostic test results for the rear display module.
[vsx-peer]
Shows the output from the VSX peer switch. If the switches do not have the VSX configuration or the ISL is down, the output from the VSX peer switch is not displayed.
Authority
Administrators
Usage
When no parameters are used in the command (show diagnostic
), the command applies to all modules.
Example
Showing diagnostic test results in brief format for all modules:
switch# show diagnostic brief Module Id Diagnostics Success Performed -------------------- ----- ----------- ------- ManagementModule 1/5 13 100% LineModule 1/1 12 100% Fabric 1/1 8 100% Fabric 1/2 8 100% Fabric 1/3 8 100% Fan 1/1 14 80% Fan 1/2 14 100% Fan 1/3 14 100% RearDisplayModule 6 100%
Showing diagnostic test results in brief format for fabrics:
switch# show diagnostic fabric brief Module Id Diagnostics Success Performed -------------------- ----- ----------- ------- Fabric 1/1 8 100% Fabric 1/2 8 100% Fabric 1/3 8 100%
Showing diagnostic test results in brief format for a specified module:
switch# show diagnostic module 1/5 brief Module Id Diagnostics Success Performed -------------------- ----- ----------- ------- ManagementModule 1/5 13 100%
Showing diagnostic test results in detail format for all modules:
switch# show diagnostic detail Module : ManagementModule 1/5 Diagnostic Status Error Code History Code Successive Total Failure Failure Count Count ------------- ------ ---------- ------------ ------------- ------------- eeprom Pass 0x0 0x0 0 0 mm_mcbe Pass 0x0 0x0 0 0 mm_mcbl Pass 0x0 0x0 0 0 pmc Pass 0x0 0x0 0 0 Total Last Run Timestamp First Run Timestamp Iteration --------- -------------------- ------------------- 2 2017-08-31 13:05:00 2017-08-31 06:40:08 79 2017-08-31 13:15:45 2017-08-31 06:40:06 79 2017-08-31 13:15:45 2017-08-31 06:40:07 79 2017-08-31 13:15:45 2017-08-31 06:40:07 Module : Fabric 1/1 Diagnostic Status Error Code History Code Successive Total Failure Failure Count Count ------------- ------ ---------- ------------ ------------- ------------- curr_sensor Pass 0x0 0x0 0 0 tmp3 Pass 0x0 0x0 0 0 tmp4 Pass 0x0 0x0 0 0 Total Last Run Timestamp First Run Timestamp Iteration --------- -------------------- ------------------- 3 2017-08-31 13:05:43 2017-08-31 06:42:32 3 2017-08-31 13:05:43 2017-08-31 06:42:32 3 2017-08-31 13:05:43 2017-08-31 06:42:32 Module : Fan 1/1 Diagnostic Status Error Code History Code Successive Total Failure Failure Count Count ------------- ------ ---------- ------------ ------------- ------------- fan1 Pass 0x0 0x0 0 0 fan1_eeprom Pass 0x0 0x0 0 0 Total Last Run Timestamp First Run Timestamp Iteration --------- -------------------- ------------------- 2 2017-08-31 13:05:01 2017-08-31 06:40:08 2 2017-08-31 13:05:01 2017-08-31 06:40:08 Module : RearDisplayModule Diagnostic Status Error Code History Code Successive Total Failure Failure Count Count ------------- ------ ---------- ------------ ------------- ------------- icb_rdc Pass 0x0 0x0 0 0 rdc_eeprom Pass 0x0 0x0 0 0 Total Last Run Timestamp First Run Timestamp Iteration --------- -------------------- ------------------- 79 2017-08-31 13:15:45 2017-08-31 06:40:13 2 2017-08-31 13:05:01 2017-08-31 06:40:13
Showing diagnostic test results in detail format for fabrics:
switch# show diagnostic fabric detail Module : Fabric 1/1 Diagnostic Status Error Code History Code Successive Total Failure Failure Count Count ------------- ------ ---------- ------------ ------------- ------------- curr_sensor Pass 0x0 0x0 0 0 eeprom_1 Pass 0x0 0x0 0 0 fc_fcb Pass 0x0 0x0 0 0 Total Last Run Timestamp First Run Timestamp Iteration --------- -------------------- ------------------- 3 2017-08-31 13:05:43 2017-08-31 06:42:32 3 2017-08-31 13:05:43 2017-08-31 06:42:32 79 2017-08-31 13:15:45 2017-08-31 06:42:32 Module : Fabric 1/2 Diagnostic Status Error Code History Code Successive Total Failure Failure Count Count ------------- ------ ---------- ------------ ------------- ------------- curr_sensor Pass 0x0 0x0 0 0 eeprom_1 Pass 0x0 0x0 0 0 fc_fcb Pass 0x0 0x0 0 0 Total Last Run Timestamp First Run Timestamp Iteration --------- -------------------- ------------------- 3 2017-08-31 13:05:43 2017-08-31 06:42:31 3 2017-08-31 13:05:42 2017-08-31 06:42:31 79 2017-08-31 13:15:45 2017-08-31 06:42:31
Showing diagnostic test results in detail format for a specified module:
switch# show diagnostic module 1/5 detail Module : ManagementModule 1/5 Diagnostic Status Error Code History Code Successive Total Failure Failure Count Count ------------- ------ ---------- ------------ ------------- ------------- eeprom Pass 0x0 0x0 0 0 ledpld Pass 0x0 0x0 0 0 lsb_altmcbl Pass 0x0 0x0 0 0 mm_mcbl Pass 0x0 0x0 0 0 pmc Pass 0x0 0x0 0 0 Total Last Run Timestamp First Run Timestamp Iteration --------- -------------------- ------------------- 2 2017-08-31 13:05:00 2017-08-31 06:40:08 80 2017-08-31 13:20:46 2017-08-31 06:40:07 80 2017-08-31 13:20:46 2017-08-31 06:40:07 80 2017-08-31 13:20:46 2017-08-31 06:40:07 80 2017-08-31 13:20:46 2017-08-31 06:40:07