Saving power by turning off FUPs with stacking disabled
Use the CLI command to turn
off
a flexible module with stacking disabled to save power. The flexible module configuration remains unchanged during a savepower operation.
Syntax
savepower flexible-module <SLOT-ID>
Description
Power flexible modules
off
.
Option
SLOT-ID
Specify an alphabetic device slot identifier A.
Example output
switch(config)# savepower flexible-module A switch(config)# savepower flexible-module A This command will shut down the specified modules. Ports on those modules will no longer pass traffic and any management traffic to ports on those modules will be interrupted. This command may take up to 2 minutes to power down all specified modules. Please use the event log to monitor progress. Continue (y/n)? y switch(config)# show modules Status and Counters - Module Information Chassis: 2930M-48G-PoE+ JL322A Serial Number: SG6JQN02R Slot Module Description Serial Number Status ----- ------------------------------------------ ---------------- ---------- A Aruba Expansion Module SavePower switch(config)# show running-config Running configuration: ; JL322A Configuration Editor; Created on release #WC.16.05.0000x ; Ver #10:9b.3f.bf.bb.ef.7c.59.fc.6b.fb.9f.fc.ff.ff.37.ef:ad hostname "Aruba-2930M-48G-PoEP" module 1 type jl322a flexible-module A type JL078A include-credentials snmp-server community "public" unrestricted snmpv3 engineid "00:00:00:0b:00:00:e0:07:1b:e5:6b:00" oobm ip address dhcp-bootp exit vlan 1 name "DEFAULT_VLAN" untagged 1-48,A1 ip address dhcp-bootp exit savepower flexible-module A