Viewing PoE status on all ports
Syntax:
show power-over-ethernet brief
Displays the port power status:
PoE Port | Lists all PoE-capable ports on the switch. |
Power Enable | Shows Yes for ports enabled to support PoE (the default) and No for ports on which PoE is disabled. |
Power Priority | Lists the power priority (Low, High, and Critical) configured on ports enabled for PoE. (For more information on this topic, see Configuring PoE operation.) |
Alloc by | Displays how PoE is allocated (usage, class, value). |
Alloc Power | The maximum amount of PoE power allocated for that port (expressed in watts).Default: 17 watts for PoE; 33 watts for PoE+. |
Actual Power | The power actually being used on that port. |
Configured Type | If configured, shows the user-specified identifier for the port. If not configured, this field is empty. |
Detection Status |
|
Power Class | Shows the 802.3af power class of the PD detected on the indicated port. Classes include:
|
The
show power-over-ethernet brief
displays this output:
show power-over-ethernet brief command output
switch(config)# show power-over-ethernet brief Status and Counters - System Power Status System Power Status : No redundancy PoE Power Status : No redundancy Available: 600 W Used: 9 W Remaining: 591 W Module A Power Available: 408 W Used: 9 W Remaining: 399 W POE | Power Power Alloc Alloc Actual Configured Detection Power Port | Enable Priority By Power Power Type Status Class ----- + ------- --------- ----- ------ ------ ----------- ---------- ---- A1 | Yes low usage 17 W 0.0 W Searching 0 A2 | Yes low usage 17 W 0.0 W Searching 0 A3 | Yes low usage 17 W 0.0 W Searching 0 A4 | Yes low usage 17 W 0.0 W Searching 0 A5 | Yes low usage 17 W 0.0 W Searching 0 A6 | Yes low usage 17 W 8.4 W Delivering 2 A7 | Yes low usage 17 W 0.0 W Searching 0 A8 | Yes low usage 17 W 0.0 W Searching 0 A9 | Yes low usage 17 W 0.0 W Searching 0
You can also show the PoE information by slot:
Showing the PoE information by slot