SNTP: Selecting and configuring

The following table shows the SNTP parameters and their operations.

Table 1: SNTP parameters

SNTP parameter

Operation

Time Sync Method

Used to select either SNTP, TIMEP, NTP, or None as the time synchronization method.

SNTP Mode

   Disabled

The Default. SNTP does not operate, even if specified by the Menu interface Time Sync Method parameter or the CLI timesync command.

   Unicast

Directs the switch to poll a specific server for SNTP time synchronization. Requires at least one server address.

   Broadcast

Directs the switch to acquire its time synchronization from data broadcast by any SNTP server to the network broadcast address. The switch uses the first server detected and ignores any others. However, if the Poll Interval expires three times without the switch detecting a time update from the original server, the switch accepts a broadcast time update from the next server it detects.

Poll Interval (seconds)

In Unicast Mode: Specifies how often the switch polls the designated SNTP server for a time update.In Broadcast Mode: Specifies how often the switch polls the network broadcast address for a time update.Value is between 30 to 720 seconds.

Server Address

Used only when the SNTP Mode is set to Unicast. Specifies the IP address of the SNTP server that the switch accesses for time synchronization updates. You can configure up to three servers; one using the menu or CLI, and two more using the CLI.

Server Version

Specifies the SNTP software version to use and is assigned on a per-server basis. The version setting is backwards-compatible. For example, using version 3 means that the switch accepts versions 1 through 3. Default: 3; range: 1 to 7.

Priority