Configuring IP MTU
NOTE:
The following feature is available on the switches
covered in this guide. jumbos
support is required
for this feature. On switches that do not support this command, the
IP MTU value is derived from the maximum frame size and is not configurable.
You can set the IP MTU globally by entering this
command. The value of max-frame-size
must be greater
than or equal to 18 bytes more than the value selected for ip-mtu
. For example, if ip-mtu
is set
to 8964, the max-frame-size
is configured as 8982.
Syntax:
jumbo ip-mtu <size>
Globally sets the IP MTU size. Values range between
1500 and 9198 bytes. This value must be 18 bytes less than the value
of max-frame-size
.
(Default: 9198 bytes)