Human readable data-path description
The OFPMP_DESC multipart response message allows an OpenFlow switch to specify a human readable text of size 255 ASCII characters.
Syntax
Openflow instance <instance-name> datapath-desc <datapath text>
Set a name to the data-path description field in the OFPMP_DESC message. By default, the data path description is set to the instance name.
Set a name to the data-path description field
switch(of-inst-test)# datapath-desc dpid1 switch(of-inst-test)# show openflow instance test Configured OF Version : 1.3 only Negotiated OF Version : 1.3 Instance Name : test Data-path Description : dpid1 Administrator Status : Enabled Member List : VLAN 3 Pipeline Model : Standard Match Listen Port : 6633 Operational Status : Up Operational Status Reason : NA Datapath ID : 000340a8f09e8600 Mode : Active Flow Location : Hardware and Software No. of Hardware Flows : 6 No. of Software Flows : 4 Hardware Rate Limit : 0 kbps Software Rate Limit : 100 pps Conn. Interrupt Mode : Fail-Secure Maximum Backoff Interval : 60 seconds Probe Interval : 10 seconds Hardware Table Miss Count : NA No. of Software Flow Tables : 1 Egress Only Ports : None Table Model : Policy Engine and Software Source MAC Group Table : Disabled Destination MAC Group Table : Disabled Controller Id Connection Status Connection State Secure Role ------------- ----------------- ---------------- ------ ------ 1 Connected Active No Equal