vsf enable
From the config context:
Syntax
vsf enable domain
<DOMAIN-ID>
Description
Enable VSF on the switch. Allows for switches to be stacked using Ethernet ports.
Parameters
- <DOMAIN-ID>
The VSF virtual chassis domain ID. Domain ID value can be in the range from 1 to 4294967296.
The command
vsf enable domain
reboots only one switch to form the VSF fabric. Upon reboot, the switches come up in the
"VSF enabled" mode. Port numbers are prefixed with member numbers, such as
"1/A1,". The configuration on the switch becoming Commander will be retained, but any pre-existing configuration on other switches
will be over-written.
The switches will inherit the same switch software as the member becoming Commander. If the software image of a switch needs to be updated, the switch will reboot twice.