power-over-ethernet vsf-member
Syntax
[no] power-over-ethernet vsf member
<MEMBER-ID> pre-std-detect [slot
<SLOT-LIST>] [ports
<PORT-LIST>]
Description
Set Power Over Ethernet (PoE) configuration parameters. Pre-standard detection and redundancy can be configured only at a per-member level when VSF is enabled.
Parameters
- <MEMBER-ID>
The VSF member-ID for the 'member' command/parameter. Member ID value can be in the range from 1 to 2.
- SLOT-ID-RANGE
Alphabetic device slot identifier or slot range.
- <PORT-LIST>
Ethernet port number, a list of ethernet ports or 'all' for all ports.
- <SLOT-ID-RANGE>
Enter an alphabetic device slot identifier or slot range preceded with the VSF member-ID [VSF-MEMBER/SLOT].
- n+1
One of the highest power supplies will be held inreserve. In the event of a simple power supply failure,no powered devices will be shut down.
- full
Half of the available power supplies will be held on reserve.
- <THRESHOLD-LEVEL>
Threshold level in the range from 1 to 99.
Usage
power-over-ethernet vsf member
<MEMBER-ID> redundancy
[n+1 | full]
[no] power-over-ethernet vsf member
<MEMBER-ID> redundancy
[n+1 | full]
power-over-ethernet vsf member
<MEMBER-ID> slot
<SLOT-ID-RANGE> threshold
<THRESHOLD-LEVEL>