Operation note
The advertisement of power with TLVs for LLDP PoE+ is enabled by default. If LLDP is disabled at runtime and a PD is using PoE+ power that has been negotiated through LLDP, there will be a temporary power drop. The port will begin using PoE+ power through the PLC. This event is recorded in the event log. An example message would look like the following:
W 08/04/10 13:35:50 02768 ports: Port A1 PoE power dropped. Exceeded physical classification for a PoE Type1 device (LLDP process disabled)
When LLDP is enabled again, it causes a temporary
power drop. This event is also recorded in the event log. An example
message looks like the following:
W 08/04/10 13:36:31 02771 ports: Port A1 PoE power dropped. Exceeded physical classification due to change in classification type (LLDP process enabled)