Booting the active management module from the current default flash
Use the
reload
command to boot the active management module from the current default flash (You can change the default flash with the
boot set-default
command. See
Setting the default flash for boot.) Switchover occurs if redundancy is enabled and the standby management module is in standby mode. If redundancy is disabled or the standby management module is not present, the
reload
command boots the system.
The
reload
command is a "warm" reboot; it skips the Power on Self Test routine.
Syntax
reload <cr>
Boots (warm reboot) the active management module. Switchover to the standby management module occurs if
management module
redundancy is enabled. If redundancy is disabled or if there is no standby management module, the
reload
command boots the system.
If the
running config
file is different from the stored config file, you are prompted to save the config file. The
reload at/after
versions of this command do not display a prompt to save configuration file changes: the changes are lost on the scheduled reload.
Example