How to troubleshoot if instance is not coming up
When an instance is not coming up, use the following commands to troubleshoot the instance status.
Procedure
-
Run the
show openflow
command.switch(openflow)# show openflow OpenFlow : Enabled Egress Only Ports Mode : Disabled Instance Information No. of No. of OpenFlow Instance Name Oper. Status H/W Flows S/W Flows Version --------------------------------- ------------ ---------- ---------- -------- test Up 0 0 1.0
-
Run the
show openflow instance <instance-name>
command.switch(openflow)# show openflow instance test Configured OF Version : 1.0 Negotiated OF Version : 1.0 Instance Name : test Data-path Description : test Administrator Status : Enabled Member List : VLAN 3 Pipeline Model : Standard Match Listen Port : 6633 Operational Status : Up Operational Status Reason : NA Datapath ID : 000340a8f09e8600 Mode : Active Flow Location : Hardware and Software No. of Hardware Flows : 0 No. of Software Flows : 0 Hardware Rate Limit : 0 kbps Software Rate Limit : 100 pps Conn. Interrupt Mode : Fail-Secure Maximum Backoff Interval : 60 seconds Probe Interval : 10 seconds Hardware Table Miss Count : 0 No. of Software Flow Tables : NA Egress Only Ports : None Table Model : Single Table Source MAC Group Table : Disabled Destination MAC Group Table : Disabled Controller Id Connection Status Connection State Secure Role ------------- ----------------- ---------------- ------ ------ 1 Disconnected Backoff No Equal