Meter statistics, scale, and limitations
Meter statistics
For meter statistics, you can use both aggregated and per band packet and byte counters.
Meter scale
Instances running pipeline model such as standard-match or custom use meters from different pools.
- 2046 is the global limit for number of meters for instances running pipeline model such as standard-match and IP-control. All instances running in either of these two pipeline models use meters from this pool.
NOTE:
The
openflow limit policy-engine-usage
command is used for determining the meter scale. By default, a total of 1,022 meters are available (default value of policy-engine-usage is 50%). - The global limit of number of meters is 2,000 for instances running in custom pipeline model.
Meter limitations
If the corresponding match does not have Ethernet type set to IPv4 or IPv6, the meter with a DSCP Remark meter band will be rejected.
- For standard-match and IP-control pipeline models:
Meters are not supported on software tables (200 to 203).
OpenFlow rules with OFPIT_METER instruction having OFPMBT_DSCP_REMARK band is not supported with OFPIT_GOTO_TABLE and OFPAT_OUTPUT to OFPP_CONTROLLER.