Events that cause a switchover
There are a number of events that can cause the active management module to switchover to the standby management module when management module redundancy is enabled:
The active management module crashes
The standby management module does not receive a heartbeat from the active management module
The
redundancy switchover
command is executedThe MM Reset button on the active management module is pressed
The MM Shutdown button on the active management module is pressed
The
boot
orboot active
command is executedThe
reload
command is executedThere is a hardware failure on the active management module
In all of these cases, the standby management module takes control and performs the actual switchover. The reason for the switchover is entered in log messages on the newly active management module and to any configured Syslog servers.