redundancy active-management
Syntax
redundancy active-management {management-module1 | management-module2 | standby}
Description
Specifies the management module that will become active at the next boot.
Command context
config
Parameters
management-module <1> | <2>
Specifies the redundant management module to enable.
standby
Specifies the standby management module.
Restrictions
The
redundancy active-management
command will fail if the other module is in a failed state or if VSF is enabled.
Usage
redundancy rapid-switchover <Seconds>
Specifies the rapid-switchover timer in seconds for L3 Hitless forwarding when used as a parameter for redundancy.
management-module
The selected active management module will continue as the active management module on boot until the user issues the command
redundancy active-management
which then changes the selected module.redundancy switchover
Instructs the switch to immediately switch over to the standby management module.
Example
Show redundancy for management module.
Switch(config)# show redundancy Configured Mode: Nonstop Switching Current Mode : Nonstop Switching Rapid Switchover Stale Timer : 90 Failovers : 0 Last Failover : Preferred Active Management: management-module1 Slot Module Description State SW Version Boot Image ---- ---------------------------------------- -------- ------------- ---------- MM1 J9827A Management Module 5400Rzl2 Active KB.16.02.0014 Primary MM2 J9827A Management Module 5400Rzl2 Standby KB.16.02.0014 Primary