Cable Diagnostics
Syntax
test cable-diagnostics <PORT-LIST>
Description
Use the command to test for cable faults.
Option
PORT-LIST
Specify copper port as a input port number.
Test cable-diagnostics C21
test cable-diagnostics C21 The 'test cable-diagnostics' command will cause a loss of link and will take a few seconds per interface to complete. Continue [Y/N]? y MDI Cable Distance Pair Pair MDI Port Pair Status to Fault Skew Polarity Mode --------- ------ -------- ----- ------ ------ C21 1-2 Open 0 m 0 ns 3-6 Open 0 m 0 ns 4-5 Open 0 m 0 ns 7-8 Open 1 m 0 ns
Test cable-diagnostics 1/1-1/10
switch# test cable-diagnostics 1/1-1/10 This command will cause a loss of link on all tested ports and will take several seconds per port to complete. Use the ‘show cable-diagnostics’ command to view the results. Continue (y/n)? Y switch# show cable-diagnostics 1/1-1/10 Cable Diagnostic Status - Copper Ports MDI Cable Cable Length or Port Pair Status Distance to Fault ---- ------ ----------- --------------------- 1/1 1-2 OK 5m 3-6 OK 5m 4-5 OK 7m 7-8 OK 7m 1/2 1-2 OK 7m 3-6 OK 7m 4-5 OK 7m 7-8 OK 7m 1/3 1-2 OK 5m 3-6 OK 7m 4-5 OK 5m 7-8 OK 7m 1/4 1-2 OK 7m 3-6 OK 7m 4-5 OK 7m 7-8 OK 5m 1/5 1-2 OK 4m 3-6 OK 5m 4-5 OK 5m 7-8 OK 4m 1/6 1-2 OK 4m 3-6 OK 4m 4-5 OK 4m 7-8 OK 4m 1/7 1-2 OK 5m 3-6 OK 4m 4-5 OK 5m 7-8 OK 4m 1/8 1-2 OK 4m 3-6 OK 5m 4-5 OK 4m 7-8 OK 4m 1/9 1-2 OK 5m 3-6 OK 5m 4-5 OK 5m 7-8 OK 5m 1/10 1-2 OK 7m 3-6 OK 5m 4-5 OK 5m 7-8 OK 5m
Good cable tests
switch# test cable-diagnostics 51 This command will cause a loss of link on all tested ports and will take several seconds per port to complete. Use the 'show cable-diagnostics' command to view the results. Continue (y/n)? Y switch# show cable-diagnostics 51 Cable Diagnostic Status - Transceiver Ports MDI Cable Distance Pair Pair MDI Port Pair Status to Fault Skew Polarity Mode ---- ------ --------- -------- ----- ------- ----- 51 1-2 OK 0 m 8 ns Normal MDI 3-6 OK 0 m 8 ns Normal 4-5 OK 0 m 8 ns Normal MDIX 7-8 OK 0 m 0 ns Normal switch# test cable-diagnostics 52 This command will cause a loss of link on all tested ports and will take several seconds per port to complete. Use the 'show cable-diagnostics' command to view the results. Continue (y/n)? Y switch# show cable-diagnostics 52 Cable Diagnostic Status - Transceiver Ports MDI Cable Distance Pair Pair MDI Port Pair Status to Fault Skew Polarity Mode ---- ------ --------- -------- ----- ------- ----- 52 1-2 OK 0 m 0 ns Normal MDI 3-6 OK 0 m 0 ns Normal 4-5 OK 0 m 0 ns Normal MDIX 7-8 OK 0 m 0 ns Normal
Faulty cable test
switch# test cable-diagnostics 51 This command will cause a loss of link on all tested ports and will take several seconds per port to complete. Use the 'show cable-diagnostics' command to view the results. Continue (y/n)? y switch# show cable-diagnostics 51 Cable Diagnostic Status - Transceiver Ports MDI Cable Distance Pair Pair MDI Port Pair Status to Fault Skew Polarity Mode ---- ------ ----------- ---------- ------ ---------- ------ 51 1-2 OK 0 m 0 ns 3-6 Short 1 m 0 ns 4-5 Short 1 m 0 ns 7-8 OK 0 m 0 ns switch# test cable-diagnostics 52 This command will cause a loss of link on all tested ports and will take several seconds per port to complete. Use the 'show cable-diagnostics' command to view the results. Continue (y/n)? Y switch# show cable-diagnostics 52 Cable Diagnostic Status - Transceiver Ports MDI Cable Distance Pair Pair MDI Port Pair Status to Fault Skew Polarity Mode ---- ------ ----------- ---------- ------ ---------- ------ 52 1-2 Open 0 m 0 ns 3-6 Open 0 m 0 ns 4-5 Open 1 m 0 ns 7-8 Open 0 m 0 ns
Error message
Error Message |
Cause |
---|---|