Enabling TimeP in Manual Mode
Like DHCP mode, configuring TimeP for Manual Mode enables TimeP. However, for manual operation, you must also specify the IP address of the TimeP server. (The switch allows only one TimeP server.) To enable the TimeP protocol:
Syntax:
timesync timep
Selects TimeP.
Syntax:
ip timep manual <ip-addr>
Activates TimeP in manual mode with a specified TimeP server.
Syntax:
[no] ip timep
Disables TimeP.
To change from one TimeP server to another, you
must use the no ip timep
command to disable TimeP
mode, the reconfigure TimeP in manual mode with the new server IP
address.
Example:
To select TimeP and configure it for manual operation using a TimeP server address of 10.28.227.141 and the default poll interval (720 minutes, assuming the TimeP poll interval is already set to the default):
switch(config)# timesync time
Selects TimeP.
switch(config)# ip timep manual 10.28.227.141
Activates TimeP in Manual mode.
Configuring TimeP for manual operation
switch(config)# timesync timep switch(config)# ip timep manual 10.28.227.141 switch(config)# show timep Timep Configuration Time Sync Mode: Timep TimeP Mode : Manual Server Address : 10.28.227.141 Poll Interval (min) : 720