Switch behavior with WebUI
The user is prompted for both username and password. Any entry including blank in the username field is allowed. This condition is true for all the below configuration.
WebUI configuration Example: 1:
Operator password: Set Manager password: Not set Operator username: Not set Manager username: Not set
Entering only the operator password, logs onto the switch in manager mode because manager password has not been set.
WebUI configuration Example: 2:
Operator password: Not set Manager password: Set Operator username: Not set Manager username: Not set
Selecting the login link on the WebUI will prompt for log in.
Entering only the manager password, logs onto the switch in manager mode.
WebUI configuration Example: 3:
Operator password: Set Manager password: Set Operator username: Not set Manager username: Not set
Logging in using the operator password logs onto the switch in operator mode.
Entering only the manager password, logs onto the switch in manager mode.
WebUI configuration Example: 4:
Operator password: Set Manager password: Set Operator username: Not set Manager username: Not set
Both Operator and Manager passwords are the same
Entering only the password, logs onto the switch in manager mode.
This feature does not capture solutions for other applications that mandate the username and does not capture the solution based on the type of management interface used.