Printable version

Drivers & software

** CRITICAL ** HP MSA 1040/2040/P2000 G3/MSA2000 G2 72GB, 146GB 15K SAS 6G SFF (DH0072FAQRD, DH0146FAQRE, EH0072FAWJA and EH0146FAWJB) Hard Drive Firmware

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPDJ(2 Dec 2013)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 4 (AMD64/EM64T)
Red Hat Enterprise Linux 4 (Itanium)
Red Hat Enterprise Linux 4 (x86)
Red Hat Enterprise Linux 5 Server (Itanium)
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Solaris 10 for x86 Systems
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (Itanium)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (Itanium)
SUSE Linux Enterprise Server 11 (x86)
VMware ESX/ESXi 4.0
VMware ESX/ESXi 4.1
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
Multi-part download
File name: HP_DH0072FAQRD_HPDJ.fla (1.1 MB)
File name: HP_DH0146FAQRE_HPDJ.fla (1.1 MB)
File name: HP_EH0072FAWJA_HPDJ.fla (1.1 MB)
File name: HP_EH0146FAWJB_HPDJ.fla (1.1 MB)
This package contains a firmware update for the hard drive models DH0072FAQRD, EH0072FAWJA (72GB 15K SAS 6G) and DH0146FAQRE, EH0146FAWJB(146GB 15K SAS 6G) when configured in HP MSA 1040/2040/P2000 G3/MSA2000 G2 storage arrays.

Prerequisites:
WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE: Drives of the same model in the storage system must have the same firmware revision.

NOTE: To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.


To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

dd4db42135f3e918991515b6c5f5a2de73423f3108ee437a8481fac5b55686ab HP_DH0146FAQRE_HPDJ.fla
dd3214662a4fb62f0d10ff65b60f0383932e9f89ac4e11294096f5ed3f0d98f8 HP_EH0146FAWJB_HPDJ.fla
e49b6b3ea0271c345974102eebe8a7d3726777f6a0d7440f4879d4b9299b603a HP_DH0072FAQRD_HPDJ.fla
f6d1ebaf696b9e75db6db56086778ed73550df7a892433cfc8a9c753b2ffcac1 HP_EH0072FAWJA_HPDJ.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:
Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware binary file in a temporary directory.
  2. Stop I/O to vdisks before starting the firmware update.
  3. Log in to the SMU select Tools > Update Firmware. A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click Install Disk Firmware File. 
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.  
Installation instructions using FTP:     

Using the SMU, prepare to use FTP:
  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP service is enabled.
  • Verify that the user you will log in as has permission to use the FTP interface and has manage access rights. 
Obtain address of the disks  
  • Obtain the address of each disk to be loaded in the form  (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
  • Note: In the WBI, the disk addresses are displayed by clicking on each enclosure in the Configuration View and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID','Slot', and'Revision'.
  • Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'. 
Instructions for updating disk firmware using FTP  
 
  1. Stop all I/O to vdisks before starting the firmware update.
  2. Place the downloaded firmware binary file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. Enter ftp . (For example: ftp 10.1.0.9)
  5. Log in via FTP with user name and password
  6. To update a specific drive, Type put filename disk:enclosure-ID:slot-number where filename is the new firmware image to load.
  7. It typically takes several minutes for the new firmware to messages will be displayed in this FTP interface during this time WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit. 
  8. Repeat steps 6-7 for each disk to update in each enclosure.
  9. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Important:
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be temporarily inaccessible and increases the risk of data loss

IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped prior to the upgrade.


Notes:

Deliverable Name:
     HP MSA 2040/P2000/MSA2000 72GB,146GB 15K SAS 6G SFF Hard Drives (DH0072FAQRD, DH0146FAQRE, EH0072FAWJA and EH0146FAWJB)

Release Version :
      HPDJ

 


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any MSA 1040/2040/P2000 G3 or MSA2000 G2 array controller enclosure.


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.  The WRITE SAME command may be used during RAID ARRAY parity initialization
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be temporarily inaccessible and increases the risk of data loss

IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped prior to the upgrade.
Version:HPDK (30 Mar 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue is fixed in this version of firmware:

  • HP ProLiant servers would power down due a hard drive overtemp condition that was falsely reported.

Version:HPDJ (2 Dec 2013)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.  The WRITE SAME command may be used during RAID ARRAY parity initialization

Version:HPDH (18 May 2012)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


  • This firmware corrects unsolicited drive resets that will cause the drive to abort any queued commands resulting in slower performance due to the host having to resubmit commands dropped and RESET events to be logged in the hardware error logs.

Version:HPDG (23 Sep 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


In a fail over environment, this firmware corrects a possible drive hang if the connection on the active ports is lost.


Version:HPDE (18 Oct 2010)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Improved seek calibration algortihms to reduce command latency.


Version:HPDD (27 Sep 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Use this firmware to flash supported drives in P2000 G3 MSA and MSA2000 G2 configurations ONLY.

Do not use this firmware to flash the drives if the drives are in any other configurations.


Initial release of specially packaged firmware for use in P2000 G3 MSA and MSA2000 G2 configurations ONLY.


Type: Firmware - SAS Storage Disk
Version: HPDJ(2 Dec 2013)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 4 (AMD64/EM64T)
Red Hat Enterprise Linux 4 (Itanium)
Red Hat Enterprise Linux 4 (x86)
Red Hat Enterprise Linux 5 Server (Itanium)
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Solaris 10 for x86 Systems
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (Itanium)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (Itanium)
SUSE Linux Enterprise Server 11 (x86)
VMware ESX/ESXi 4.0
VMware ESX/ESXi 4.1
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5

Description

This package contains a firmware update for the hard drive models DH0072FAQRD, EH0072FAWJA (72GB 15K SAS 6G) and DH0146FAQRE, EH0146FAWJB(146GB 15K SAS 6G) when configured in HP MSA 1040/2040/P2000 G3/MSA2000 G2 storage arrays.

Installation Instructions

Prerequisites:
WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE: Drives of the same model in the storage system must have the same firmware revision.

NOTE: To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.


To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

dd4db42135f3e918991515b6c5f5a2de73423f3108ee437a8481fac5b55686ab HP_DH0146FAQRE_HPDJ.fla
dd3214662a4fb62f0d10ff65b60f0383932e9f89ac4e11294096f5ed3f0d98f8 HP_EH0146FAWJB_HPDJ.fla
e49b6b3ea0271c345974102eebe8a7d3726777f6a0d7440f4879d4b9299b603a HP_DH0072FAQRD_HPDJ.fla
f6d1ebaf696b9e75db6db56086778ed73550df7a892433cfc8a9c753b2ffcac1 HP_EH0072FAWJA_HPDJ.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:
Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware binary file in a temporary directory.
  2. Stop I/O to vdisks before starting the firmware update.
  3. Log in to the SMU select Tools > Update Firmware. A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click Install Disk Firmware File. 
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.  
Installation instructions using FTP:     

Using the SMU, prepare to use FTP:
  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP service is enabled.
  • Verify that the user you will log in as has permission to use the FTP interface and has manage access rights. 
Obtain address of the disks  
  • Obtain the address of each disk to be loaded in the form  (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
  • Note: In the WBI, the disk addresses are displayed by clicking on each enclosure in the Configuration View and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID','Slot', and'Revision'.
  • Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'. 
Instructions for updating disk firmware using FTP  
 
  1. Stop all I/O to vdisks before starting the firmware update.
  2. Place the downloaded firmware binary file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. Enter ftp . (For example: ftp 10.1.0.9)
  5. Log in via FTP with user name and password
  6. To update a specific drive, Type put filename disk:enclosure-ID:slot-number where filename is the new firmware image to load.
  7. It typically takes several minutes for the new firmware to messages will be displayed in this FTP interface during this time WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit. 
  8. Repeat steps 6-7 for each disk to update in each enclosure.
  9. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Important:
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be temporarily inaccessible and increases the risk of data loss

IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped prior to the upgrade.


Notes:

Deliverable Name:
     HP MSA 2040/P2000/MSA2000 72GB,146GB 15K SAS 6G SFF Hard Drives (DH0072FAQRD, DH0146FAQRE, EH0072FAWJA and EH0146FAWJB)

Release Version :
      HPDJ

 


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any MSA 1040/2040/P2000 G3 or MSA2000 G2 array controller enclosure.


Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.  The WRITE SAME command may be used during RAID ARRAY parity initialization

Important

CAUTION: Updating firmware on drives in a virtual disk causes the drives to be temporarily inaccessible and increases the risk of data loss

IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped prior to the upgrade.

Revision History

Version:HPDK (30 Mar 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue is fixed in this version of firmware:

  • HP ProLiant servers would power down due a hard drive overtemp condition that was falsely reported.

Version:HPDJ (2 Dec 2013)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.  The WRITE SAME command may be used during RAID ARRAY parity initialization

Version:HPDH (18 May 2012)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


  • This firmware corrects unsolicited drive resets that will cause the drive to abort any queued commands resulting in slower performance due to the host having to resubmit commands dropped and RESET events to be logged in the hardware error logs.

Version:HPDG (23 Sep 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


In a fail over environment, this firmware corrects a possible drive hang if the connection on the active ports is lost.


Version:HPDE (18 Oct 2010)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Improved seek calibration algortihms to reduce command latency.


Version:HPDD (27 Sep 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Use this firmware to flash supported drives in P2000 G3 MSA and MSA2000 G2 configurations ONLY.

Do not use this firmware to flash the drives if the drives are in any other configurations.


Initial release of specially packaged firmware for use in P2000 G3 MSA and MSA2000 G2 configurations ONLY.


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.