File name: hpe-esxi6.0uX-bundle-2.6.0-22.zip (11 MB)
HPE ESXi Offline Bundle for VMware ESXi 6.0. The HPE ESXi Offline Bundle for VMware ESXi 6.0 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries.

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Provider features:

  • Added support for Megacell smart battery in the Smart Array Provider

 

 

 

 

To ensure the integrity of your download, HPE recommends verifying your results with this MD5 Checksum value:

1a7937dbd86819cd413145a77951b924 hpe-esxi6.0uX-bundle-2.6.0-22.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installing Offline Bundles on an vSphere 6.0 Host Using vSphere CLI 6.0 esxcli Utility

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes
the procedure using offline bundles.

This bundle includes the following software versions:

  • hpe-smx-provider-600.03.11.00.9-2768847
  • amshelper-600.10.5.0-24.2494585
  • hpe-ilo_600.10.0.0.26-1OEM.600.0.0.2494585
  • hpe-cru_6.0.8.6-1OEM.600.0.0.2494585
  • hpe-esxi-fc-enablement-600.2.6.20-2494585

This is not intended for VMware ESXi 4.1.x.

Prerequisites
Before you can update or patch an vSphere 6.0 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.0 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the
vSphere CLI 6.0, see the VMware vSphere Command-Line Interface Installation and Reference Guide.

Procedure

  1. Power off any virtual machines that are running on the host and place the host into maintenance mode.
  2. Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
  3. Install the bundle on the ESXi host.
    • Install remotely from client, with offline bundle contents on a online depot:
         esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
    • Install remotely from client, with offline bundle on ESXi host:
         esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
    • Install from ESXi host, with offline bundle on ESXi host:
         esxcli software vib install -d <ESXi local path><bundle.zip>
  4. After the bundle is installed, reboot the ESXi host for the updates to take effect.
  5. (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
       esxcli -s <server> -u root -p mypassword software vib list
  6. (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
       esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>

  Installing Offline Bundles on an vSphere 6.0 Host Using VMware vCenter Update Manager

The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.

 


End User License Agreements:
HPE Software License Agreement v1
Eclipse License
Libcurl End User License Agreement
Net-SNMP License
SNIA License
zlib End User License Agreement
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

The HPE management software is not supported for the following devices:

  • HPE StoreFabric SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter

  • HPE StoreFabric SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter

  • HPE StoreFabric SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter

  • HPE StoreFabric 84E 4-port 8Gb Fibre Channel Host Bus Adapter

  • HPE Ethernet 10/25Gb 2-port 640FLR-SFP28 Adapter         

  • HPE Ethernet 10/25Gb 2-port 640SFP28 Adapter

Refer to the drivers and firmware recipe information for ProLiant servers and options at http://www.hpe.com/info/vmware-recipes


Notes:

The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License.
A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/


Supported Devices and Features:

VMware vSphere version support:

  • VMware vSphere 6.0 U1
  • VMware vSphere 6.0 U2

 


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


AMS Fixes:

  • •Fixed missing driver information in AHS log
  • Fixed missing cpqFca instances at first boot after install with HPE CNAs with Software FCoE for the following adapters:
    • HP FlexFabric 20Gb 2P 630FLB Adptr
    • HP FlexFabric 20Gb 2P 630M Adptr
    • HP FlexFabric 10Gb 2P 536FLB Adptr
    • HPE CN1100R 2P Converged Network Adapter
    • HPE CN1100R-T 2P Converged Network Adapter
    • HP FlexFabric 10Gb 2P 534FLB Adptr
    • HP FlexFabric 10Gb 2P 534FLR-SFP+ Adptr
    • HP FlexFabric 10Gb 2P 534M Adptr
    • HP FlexFabric 10Gb 2P 533FLR-T Adptr
  • HPE Insight Management WBEM Providers report incorrect number of Ethernet Ports - When FCoE Adapter “HPE FlexFabric 10Gb 2-port 536FLB” is installed, server is configured as a combination of Ethernet ports (FCoE)) and FC ports (Storage). When the FC port connections are taken from FC switch, HPE Insight Management WBEM Providers report all the ports including the FC ports as Ethernet port.
  • HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and accordingly WBEM indications are also not getting generated - When FC Adapter “HPE FlexFabric 10Gb 2-port 536FLB” is installed on a server and if the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providersreports wrong value for the OperationalStatus property in FC Provider classes. Also the WBEM indications does not get generated. OperationalStatus reflects with changed status only after WBEM Provider restarts.

 

The HPE management software is not supported for the following devices:

  • HPE StoreFabric SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter

  • HPE StoreFabric SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter

  • HPE StoreFabric SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter

  • HPE StoreFabric 84E 4-port 8Gb Fibre Channel Host Bus Adapter

  • HPE Ethernet 10/25Gb 2-port 640FLR-SFP28 Adapter         

  • HPE Ethernet 10/25Gb 2-port 640SFP28 Adapter

Refer to the drivers and firmware recipe information for ProLiant servers and options at http://www.hpe.com/info/vmware-recipes

Version:3.4.5 (16 Sep 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Agentless Management Service

Enhancements

Agentless Management Service

  • Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter

Version:3.4.0 (2 Apr 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


WBEM Providers

  • Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider

Agentless Management Service

  • Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM
Enhancements

Agentless Management Service

  • Added support for cpqiscsi MIB
  • Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log

Version:3.3.6 (29 Nov 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


 

Agentless Management Service

  • Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
  • Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.

Version:3.3.0 (27 Jun 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


WBEM Providers

  • Fixed issue with Smart Array Provider reporting change of battery status frequently

Agentless Management Service

  • Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
  • Fixed memory leak partly caused by AMS running in the OS init resource group
  • Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display
Enhancements

WBEM Providers

  • Added support for Smart Array Controller model P408i-sb

Agentless Management Service

  • Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log 

Version:3.2.0 (21 Mar 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


WBEM Providers

  • Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at: http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
  • Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at: http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us
  • Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
  • Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.

Agentless Management Service

  • Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system.
Enhancements

Agentless Management Service

  • Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device 
  • Added support for HPE Smart Array P824i-p MR controller
  • Added support for reporting multiple IPV6 addresses configured for Ethernet ports
  • Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
  • Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers
  • Added support for Broadcom NetXtreme-E Adapter
  • Added support for QLogic FastLinQ 10/25/50 GbE Multifunction Adapters

Version:3.1.5 (9 Nov 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


HPE Insight Management WBEM Providers:

  • Fixed memory leak -  For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.

  • HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5 - This issue is observed on both vSphere 6.0 and 6.5, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.

  • HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated - When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.

 

HPE Agentless Management Service:

  • Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.

 


Version:3.1.0 (12 Jul 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


AMS fixes:

  • Fixed incorrect Degraded Status for SATA drives attached to the embedded SATA controller
  • Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
  • Fixed AMS crash when multiple NICs of the same driver are installed
Enhancements

WBEM Provider features:

  • Added support for smartpqi driver and Gen10 Smart Array controllers
  • Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility
  • Added Firmware update audit logging support to Smart Component Installer provider
  • Added support for Mellanox ConnectX-4 Ethernet Controller for vSphere 6.0

AMS features:

  • Added support for HPE Ethernet 25Gb 2-port 640SFP28 Adapter, PE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter, HP Ethernet 10Gb 2-port 546FLR-SFP+ Adapter, HP Ethernet 10Gb 2-port 546SFP+ Adapter  

  • Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port

  • Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor

Agentless Management Service script  to manually stop or restart AMS has changed (from hp-ams.sh) to ams.sh


Version:2.6.0 (25 Oct 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


AMS Fixes:

  • •Fixed missing driver information in AHS log
  • Fixed missing cpqFca instances at first boot after install with HPE CNAs with Software FCoE for the following adapters:
    • HP FlexFabric 20Gb 2P 630FLB Adptr
    • HP FlexFabric 20Gb 2P 630M Adptr
    • HP FlexFabric 10Gb 2P 536FLB Adptr
    • HPE CN1100R 2P Converged Network Adapter
    • HPE CN1100R-T 2P Converged Network Adapter
    • HP FlexFabric 10Gb 2P 534FLB Adptr
    • HP FlexFabric 10Gb 2P 534FLR-SFP+ Adptr
    • HP FlexFabric 10Gb 2P 534M Adptr
    • HP FlexFabric 10Gb 2P 533FLR-T Adptr
  • HPE Insight Management WBEM Providers report incorrect number of Ethernet Ports - When FCoE Adapter “HPE FlexFabric 10Gb 2-port 536FLB” is installed, server is configured as a combination of Ethernet ports (FCoE)) and FC ports (Storage). When the FC port connections are taken from FC switch, HPE Insight Management WBEM Providers report all the ports including the FC ports as Ethernet port.
  • HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and accordingly WBEM indications are also not getting generated - When FC Adapter “HPE FlexFabric 10Gb 2-port 536FLB” is installed on a server and if the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providersreports wrong value for the OperationalStatus property in FC Provider classes. Also the WBEM indications does not get generated. OperationalStatus reflects with changed status only after WBEM Provider restarts.

 

Enhancements

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Provider features:

  • Added support for Megacell smart battery in the Smart Array Provider

 

 

 

 


Version:2.5.0 (12 Apr 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


AMS Fixes:

  • Fixed incomplete process names in cpqHoSWRunningName
  • Fixed multiple issues with specific devices in cpqSePciSlotEntry, cpqSePciSlotBoardNameand cpqSePciSlotCurrentMode
Enhancements

Supports the new Gen9 HPE ProLiant servers with Intel Xeon E5-2600-v4 Series processors

AMS features:

  • Fixed incomplete process names in cpqHoSWRunningName
  • Fixed multiple issues with specific devices

Version:2.4 (1 Oct 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Provider Fixes:

  • Fixed the issue due to which Mellanox network cards were not supported by HP Insight Management WBEM provider on vSphere 6.0
  • Fixed Provider memory leak issue when there are FCHBA or CNA installed on the system

AMS Fixes:

  • Fixed hrSWInstalledDate to report proper date values instead of zeroes
  • Fixed issue of missing ESX software in hrSWInstalledTable

 

Enhancements

AMS New Features:

  • Add reporting of OS build Patch Number in cpqHost MIB Name, Version and Description

Provider New Features:

  • Added support for forwarding SNMP traps to iLO SNMP pass through
  • Added support for Mellanox network cards on vSphere 6.0

Version:2.3.50 (28 Oct 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Provider Fixes:

  • Fixed the issue due to which Mellanox network cards were not supported by HP Insight Management WBEM provider on vSphere 6.0.
  • Fixed Provider memory leak issue when there is a FCHBA and CNA installed on the system.

AMS Fixes:

  • Fixed the issue where the NIC MIB condition is not updated in the cpqHoMibHealthStatusArray in some instances.
  • Fixed the regression issue of not reporting HP FCHBA models 81B and 82B in the cpqFca MIB.
Enhancements

Supports VMware vSphere 6.0 U1

Provider Features:

  • Added support for forwarding SNMP traps to iLO SNMP pass through.
  • Added support for Mellanox network cards on vSphere 6.0.

AMS Features:

  • Reporting of hrSWInstalled MIB
  • Reporting of NIC Option Kit SKU Part Number in cpqNic MIB

Version:2.3 (15 Jun 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


HP Insight Management WBEM Providers Fixes:

  • Fixed the issue where HP Insight Management WBEM provider reports wrong value for power supply slot number in HP ProLiant DL580 Gen9 Server
  • Fixed the issue where HP Insight Management WBEM provider stops sending indications to Insight Remote Support installed within a Converged System 700 for Virtualization solution after a few days. This issue was also observed in Converged System 300 for Virtualization and Cloud System 8.0 Solution.
  • HP Management WBEM provider support added for the following HP FCoE devices:
    • HP StoreFabric CN1100R Dual Port Converged Network Adapter
    • HP FlexFabric 10Gb 2-port 534FLB Adapter
    • HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter
    • HP FlexFabric 10Gb 2-port 534M Adapter
    • HP FlexFabric 20Gb 2-port 630FLB Adapter
    • HP FlexFabric 20Gb 2-port 630M Adapter
    • HP FlexFabric 10Gb 2-port 536FLB Adapter

HP AMS Fixes:

  • Fixed issue where the NIC MIB condition is not updated in the cpqHoMibHealthStatusArray in some instances
  • Fixed regression issue of not reporting the HP StorageWorks 81B 8Gb Single Port PCI-e FC HBA and HP StorageWorks 82B 8Gb Dual Port PCI-e FC HBA in the cpqFca MIB
Enhancements

HP Insight Management WBEM Providers Features::

  •  Support for new HP Smart Array controllers
  •  Added support for Smart Array disk drive Sanitize feature

HP AMS Features:

  • Reporting of hrSWInstalled MIB
  • Reporting of NIC Option Kit SKU Part Number in cpqNic MIB

Version:2.2 (30 Mar 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


HP Insight Management WBEM Providers Fix:

  • Fixed the issue where HP Insight Management WBEM providers for VMWare ESXi reports improper information for VersionString, ReleaseDate, MajorVersion and MinorVersion properties for Redundant ROM.

AMS Fix:  

  • When cpqFca3hostCntlrStatusChange trap occurs, the software now reports a FC Port status change from Link Up to Link Down with a trap Severity value of Informational, and a trap Condition value of OK. This change was made to be consistent with other HP management software.
Enhancements

AMS Features:

  • Reporting of SAS/SATA SSD and temperature properties to cpqSasPhyDrvTable MIB
  • Reporting of SATA SSD and temperature properties to cpqIdeAtaDiskTable MIB
  • Supports new cpqSeUSBPortTable MIB, SNMP traps and IML events for new HP Dual 8GB MicroSD EM USB Kit device

Added support for the following servers:

  • HP ProLiant XL190r Gen9
  • HP ProLiant XL170r Gen9

 


Version:2.1 (12 Mar 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


The following fix has been made:

  • Improper information for Redundant ROM properties - Fixed the issue where HP Insight Management WBEM providers for VMware ESXi reports improper information for VersionString, ReleaseDate, MajorVersion and MinorVersion properties for Redundant ROM.

The following fix has been made to the HP Agentless Management Service (AMS):

  • Fixed reporting of cpqFca3HostCntlrStatusChange trap to indicate Informational Severity and OK status (Not Connected) for FC Port Link Up to Link Down change for consistency with other HP management software.
Enhancements

Agentless Management Service (AMS) New Features:

  • Reporting of SAS/SATA SSD and temperature properties to cpqSasPhyDrvTable MIB
  • Reporting of SATA SSD and temperature properties to cpqIdeAtaDiskTable MIB

Type: Software - System Management
Version: 2.6.0(25 Oct 2016)
Operating System(s):
VMware vSphere 6.0

Description

HPE ESXi Offline Bundle for VMware ESXi 6.0. The HPE ESXi Offline Bundle for VMware ESXi 6.0 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries.

Enhancements

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Provider features:

  • Added support for Megacell smart battery in the Smart Array Provider

 

 

 

 

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with this MD5 Checksum value:

1a7937dbd86819cd413145a77951b924 hpe-esxi6.0uX-bundle-2.6.0-22.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installing Offline Bundles on an vSphere 6.0 Host Using vSphere CLI 6.0 esxcli Utility

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes
the procedure using offline bundles.

This bundle includes the following software versions:

  • hpe-smx-provider-600.03.11.00.9-2768847
  • amshelper-600.10.5.0-24.2494585
  • hpe-ilo_600.10.0.0.26-1OEM.600.0.0.2494585
  • hpe-cru_6.0.8.6-1OEM.600.0.0.2494585
  • hpe-esxi-fc-enablement-600.2.6.20-2494585

This is not intended for VMware ESXi 4.1.x.

Prerequisites
Before you can update or patch an vSphere 6.0 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.0 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the
vSphere CLI 6.0, see the VMware vSphere Command-Line Interface Installation and Reference Guide.

Procedure

  1. Power off any virtual machines that are running on the host and place the host into maintenance mode.
  2. Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
  3. Install the bundle on the ESXi host.
    • Install remotely from client, with offline bundle contents on a online depot:
         esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
    • Install remotely from client, with offline bundle on ESXi host:
         esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
    • Install from ESXi host, with offline bundle on ESXi host:
         esxcli software vib install -d <ESXi local path><bundle.zip>
  4. After the bundle is installed, reboot the ESXi host for the updates to take effect.
  5. (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
       esxcli -s <server> -u root -p mypassword software vib list
  6. (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
       esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>

  Installing Offline Bundles on an vSphere 6.0 Host Using VMware vCenter Update Manager

The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.

 


Release Notes

End User License Agreements:
HPE Software License Agreement v1
Eclipse License
Libcurl End User License Agreement
Net-SNMP License
SNIA License
zlib End User License Agreement
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

The HPE management software is not supported for the following devices:

  • HPE StoreFabric SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter

  • HPE StoreFabric SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter

  • HPE StoreFabric SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter

  • HPE StoreFabric 84E 4-port 8Gb Fibre Channel Host Bus Adapter

  • HPE Ethernet 10/25Gb 2-port 640FLR-SFP28 Adapter         

  • HPE Ethernet 10/25Gb 2-port 640SFP28 Adapter

Refer to the drivers and firmware recipe information for ProLiant servers and options at http://www.hpe.com/info/vmware-recipes


Notes:

The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License.
A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/


Supported Devices and Features:

VMware vSphere version support:

  • VMware vSphere 6.0 U1
  • VMware vSphere 6.0 U2

 


Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


AMS Fixes:

  • •Fixed missing driver information in AHS log
  • Fixed missing cpqFca instances at first boot after install with HPE CNAs with Software FCoE for the following adapters:
    • HP FlexFabric 20Gb 2P 630FLB Adptr
    • HP FlexFabric 20Gb 2P 630M Adptr
    • HP FlexFabric 10Gb 2P 536FLB Adptr
    • HPE CN1100R 2P Converged Network Adapter
    • HPE CN1100R-T 2P Converged Network Adapter
    • HP FlexFabric 10Gb 2P 534FLB Adptr
    • HP FlexFabric 10Gb 2P 534FLR-SFP+ Adptr
    • HP FlexFabric 10Gb 2P 534M Adptr
    • HP FlexFabric 10Gb 2P 533FLR-T Adptr
  • HPE Insight Management WBEM Providers report incorrect number of Ethernet Ports - When FCoE Adapter “HPE FlexFabric 10Gb 2-port 536FLB” is installed, server is configured as a combination of Ethernet ports (FCoE)) and FC ports (Storage). When the FC port connections are taken from FC switch, HPE Insight Management WBEM Providers report all the ports including the FC ports as Ethernet port.
  • HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and accordingly WBEM indications are also not getting generated - When FC Adapter “HPE FlexFabric 10Gb 2-port 536FLB” is installed on a server and if the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providersreports wrong value for the OperationalStatus property in FC Provider classes. Also the WBEM indications does not get generated. OperationalStatus reflects with changed status only after WBEM Provider restarts.

 

Important

The HPE management software is not supported for the following devices:

  • HPE StoreFabric SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter

  • HPE StoreFabric SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter

  • HPE StoreFabric SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter

  • HPE StoreFabric 84E 4-port 8Gb Fibre Channel Host Bus Adapter

  • HPE Ethernet 10/25Gb 2-port 640FLR-SFP28 Adapter         

  • HPE Ethernet 10/25Gb 2-port 640SFP28 Adapter

Refer to the drivers and firmware recipe information for ProLiant servers and options at http://www.hpe.com/info/vmware-recipes

Revision History

Version:3.4.5 (16 Sep 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Agentless Management Service

Enhancements

Agentless Management Service

  • Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter

Version:3.4.0 (2 Apr 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


WBEM Providers

  • Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider

Agentless Management Service

  • Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM
Enhancements

Agentless Management Service

  • Added support for cpqiscsi MIB
  • Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log

Version:3.3.6 (29 Nov 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


 

Agentless Management Service

  • Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
  • Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.

Version:3.3.0 (27 Jun 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


WBEM Providers

  • Fixed issue with Smart Array Provider reporting change of battery status frequently

Agentless Management Service

  • Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
  • Fixed memory leak partly caused by AMS running in the OS init resource group
  • Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display
Enhancements

WBEM Providers

  • Added support for Smart Array Controller model P408i-sb

Agentless Management Service

  • Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log 

Version:3.2.0 (21 Mar 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


WBEM Providers

  • Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at: http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
  • Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at: http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us
  • Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
  • Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.

Agentless Management Service

  • Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system.
Enhancements

Agentless Management Service

  • Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device 
  • Added support for HPE Smart Array P824i-p MR controller
  • Added support for reporting multiple IPV6 addresses configured for Ethernet ports
  • Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
  • Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers
  • Added support for Broadcom NetXtreme-E Adapter
  • Added support for QLogic FastLinQ 10/25/50 GbE Multifunction Adapters

Version:3.1.5 (9 Nov 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


HPE Insight Management WBEM Providers:

  • Fixed memory leak -  For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.

  • HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5 - This issue is observed on both vSphere 6.0 and 6.5, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.

  • HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated - When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.

 

HPE Agentless Management Service:

  • Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.

 


Version:3.1.0 (12 Jul 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


AMS fixes:

  • Fixed incorrect Degraded Status for SATA drives attached to the embedded SATA controller
  • Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
  • Fixed AMS crash when multiple NICs of the same driver are installed
Enhancements

WBEM Provider features:

  • Added support for smartpqi driver and Gen10 Smart Array controllers
  • Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility
  • Added Firmware update audit logging support to Smart Component Installer provider
  • Added support for Mellanox ConnectX-4 Ethernet Controller for vSphere 6.0

AMS features:

  • Added support for HPE Ethernet 25Gb 2-port 640SFP28 Adapter, PE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter, HP Ethernet 10Gb 2-port 546FLR-SFP+ Adapter, HP Ethernet 10Gb 2-port 546SFP+ Adapter  

  • Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port

  • Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor

Agentless Management Service script  to manually stop or restart AMS has changed (from hp-ams.sh) to ams.sh


Version:2.6.0 (25 Oct 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


AMS Fixes:

  • •Fixed missing driver information in AHS log
  • Fixed missing cpqFca instances at first boot after install with HPE CNAs with Software FCoE for the following adapters:
    • HP FlexFabric 20Gb 2P 630FLB Adptr
    • HP FlexFabric 20Gb 2P 630M Adptr
    • HP FlexFabric 10Gb 2P 536FLB Adptr
    • HPE CN1100R 2P Converged Network Adapter
    • HPE CN1100R-T 2P Converged Network Adapter
    • HP FlexFabric 10Gb 2P 534FLB Adptr
    • HP FlexFabric 10Gb 2P 534FLR-SFP+ Adptr
    • HP FlexFabric 10Gb 2P 534M Adptr
    • HP FlexFabric 10Gb 2P 533FLR-T Adptr
  • HPE Insight Management WBEM Providers report incorrect number of Ethernet Ports - When FCoE Adapter “HPE FlexFabric 10Gb 2-port 536FLB” is installed, server is configured as a combination of Ethernet ports (FCoE)) and FC ports (Storage). When the FC port connections are taken from FC switch, HPE Insight Management WBEM Providers report all the ports including the FC ports as Ethernet port.
  • HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and accordingly WBEM indications are also not getting generated - When FC Adapter “HPE FlexFabric 10Gb 2-port 536FLB” is installed on a server and if the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providersreports wrong value for the OperationalStatus property in FC Provider classes. Also the WBEM indications does not get generated. OperationalStatus reflects with changed status only after WBEM Provider restarts.

 

Enhancements

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Provider features:

  • Added support for Megacell smart battery in the Smart Array Provider

 

 

 

 


Version:2.5.0 (12 Apr 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


AMS Fixes:

  • Fixed incomplete process names in cpqHoSWRunningName
  • Fixed multiple issues with specific devices in cpqSePciSlotEntry, cpqSePciSlotBoardNameand cpqSePciSlotCurrentMode
Enhancements

Supports the new Gen9 HPE ProLiant servers with Intel Xeon E5-2600-v4 Series processors

AMS features:

  • Fixed incomplete process names in cpqHoSWRunningName
  • Fixed multiple issues with specific devices

Version:2.4 (1 Oct 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Provider Fixes:

  • Fixed the issue due to which Mellanox network cards were not supported by HP Insight Management WBEM provider on vSphere 6.0
  • Fixed Provider memory leak issue when there are FCHBA or CNA installed on the system

AMS Fixes:

  • Fixed hrSWInstalledDate to report proper date values instead of zeroes
  • Fixed issue of missing ESX software in hrSWInstalledTable

 

Enhancements

AMS New Features:

  • Add reporting of OS build Patch Number in cpqHost MIB Name, Version and Description

Provider New Features:

  • Added support for forwarding SNMP traps to iLO SNMP pass through
  • Added support for Mellanox network cards on vSphere 6.0

Version:2.3.50 (28 Oct 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Provider Fixes:

  • Fixed the issue due to which Mellanox network cards were not supported by HP Insight Management WBEM provider on vSphere 6.0.
  • Fixed Provider memory leak issue when there is a FCHBA and CNA installed on the system.

AMS Fixes:

  • Fixed the issue where the NIC MIB condition is not updated in the cpqHoMibHealthStatusArray in some instances.
  • Fixed the regression issue of not reporting HP FCHBA models 81B and 82B in the cpqFca MIB.
Enhancements

Supports VMware vSphere 6.0 U1

Provider Features:

  • Added support for forwarding SNMP traps to iLO SNMP pass through.
  • Added support for Mellanox network cards on vSphere 6.0.

AMS Features:

  • Reporting of hrSWInstalled MIB
  • Reporting of NIC Option Kit SKU Part Number in cpqNic MIB

Version:2.3 (15 Jun 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


HP Insight Management WBEM Providers Fixes:

  • Fixed the issue where HP Insight Management WBEM provider reports wrong value for power supply slot number in HP ProLiant DL580 Gen9 Server
  • Fixed the issue where HP Insight Management WBEM provider stops sending indications to Insight Remote Support installed within a Converged System 700 for Virtualization solution after a few days. This issue was also observed in Converged System 300 for Virtualization and Cloud System 8.0 Solution.
  • HP Management WBEM provider support added for the following HP FCoE devices:
    • HP StoreFabric CN1100R Dual Port Converged Network Adapter
    • HP FlexFabric 10Gb 2-port 534FLB Adapter
    • HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter
    • HP FlexFabric 10Gb 2-port 534M Adapter
    • HP FlexFabric 20Gb 2-port 630FLB Adapter
    • HP FlexFabric 20Gb 2-port 630M Adapter
    • HP FlexFabric 10Gb 2-port 536FLB Adapter

HP AMS Fixes:

  • Fixed issue where the NIC MIB condition is not updated in the cpqHoMibHealthStatusArray in some instances
  • Fixed regression issue of not reporting the HP StorageWorks 81B 8Gb Single Port PCI-e FC HBA and HP StorageWorks 82B 8Gb Dual Port PCI-e FC HBA in the cpqFca MIB
Enhancements

HP Insight Management WBEM Providers Features::

  •  Support for new HP Smart Array controllers
  •  Added support for Smart Array disk drive Sanitize feature

HP AMS Features:

  • Reporting of hrSWInstalled MIB
  • Reporting of NIC Option Kit SKU Part Number in cpqNic MIB

Version:2.2 (30 Mar 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


HP Insight Management WBEM Providers Fix:

  • Fixed the issue where HP Insight Management WBEM providers for VMWare ESXi reports improper information for VersionString, ReleaseDate, MajorVersion and MinorVersion properties for Redundant ROM.

AMS Fix:  

  • When cpqFca3hostCntlrStatusChange trap occurs, the software now reports a FC Port status change from Link Up to Link Down with a trap Severity value of Informational, and a trap Condition value of OK. This change was made to be consistent with other HP management software.
Enhancements

AMS Features:

  • Reporting of SAS/SATA SSD and temperature properties to cpqSasPhyDrvTable MIB
  • Reporting of SATA SSD and temperature properties to cpqIdeAtaDiskTable MIB
  • Supports new cpqSeUSBPortTable MIB, SNMP traps and IML events for new HP Dual 8GB MicroSD EM USB Kit device

Added support for the following servers:

  • HP ProLiant XL190r Gen9
  • HP ProLiant XL170r Gen9

 


Version:2.1 (12 Mar 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


The following fix has been made:

  • Improper information for Redundant ROM properties - Fixed the issue where HP Insight Management WBEM providers for VMware ESXi reports improper information for VersionString, ReleaseDate, MajorVersion and MinorVersion properties for Redundant ROM.

The following fix has been made to the HP Agentless Management Service (AMS):

  • Fixed reporting of cpqFca3HostCntlrStatusChange trap to indicate Informational Severity and OK status (Not Connected) for FC Port Link Up to Link Down change for consistency with other HP management software.
Enhancements

Agentless Management Service (AMS) New Features:

  • Reporting of SAS/SATA SSD and temperature properties to cpqSasPhyDrvTable MIB
  • Reporting of SATA SSD and temperature properties to cpqIdeAtaDiskTable MIB

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.