Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Windows - HP P2000/MSA2000 146GB,300GB 10K SAS 6G SFF Hard Drive (EG0146FARTR and EG0300FARTT)

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD9(17 Aug 2011)
Operating System(s): Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
File name: cp014547.exe (2.6 MB)
This Windows Smart Component contains a firmware update for the hard drive models EG0146FARTR (146GB 10K SAS 6G) and EG0300FARTT (300GB 10K SAS 6G) in HP P2000 G3 MSA and MSA2000 G2 configurations.

This firmware improves the hard drive servo control which reduces the number of positioning errors. 

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

2802195127b1ae67ff75998993be9dc4 cp014547.exe

Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of array controller


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


Notes:

Deliverable Name:

    Firmware Flash Component for Windows - HP P2000/MSA2000 146GB,300GB 10K SAS 6G SFF Hard Drive (EG0146FARTR and EG0300FARTT)

Release Version and/or Date:
      HPD9

Last Recommended or Critical Version:
      HPD5

Previous Version of Firmware:
      HPD5

Firmware Dependency:
     None

Enhancements/New Features:
     This firmware improves the hard drive servo control which reduces the number of positioning errors.

Problems Fixed:
     
   Resolved an issue with 01/5D/32 error in SMART log.  Read-Write Error Recovery issue may cause HDD to time-out.  Full recovery from this error can take several seconds.

Known Issues:
     None

Failure Considerations:

  1. Single ported drive will not be flashed if the owner controller of that drive is not accessible through network.
  2. Drives will not be flashed if the drive is in a virtual disk which is being initialized, expanded, reconstructed, verified, or scrubbed.
  3. Flash operation on any pending disks will be aborted if the currently flashed drive is in LEFTOVR state or the virtual disk containing this disk is found to be in offline or critical state. If this does occur, the vdisk can be restored to online status by changing the drive status from leftover to available and then adding the drive to the vdisk as a spare. If a global spare drive was available, it will have been used to restore the vdisk to online status.

Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any HP P2000 G3 or MSA2000 G2 array controller enclosure.


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Resolved an issue with 01/5D/32 error in SMART log.  Read-Write Error Recovery issue may cause HDD to time-out.  Full recovery from this error can take several seconds.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.

Version:HPDA (A) (15 Aug 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware HPDA(A) is not necessary if the HDD is currently running HPDA firmware.


The following issue was fixed in HPDA:

  • Firmware now correctly reports the maximum drive recommended operating temperature.  The incorrect values reported in previous versions of the FW caused ProLiant system fans to operate at improper speeds.
Enhancements

In this version the Smart Component was updated to support MSA 1040/2040 arrays.


Version:HPDA (18 May 2012)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Problems Fixed:  

Firmware version HPDA now correctly reports the maximum drive recommended operating temperature.  The incorrect values reported in previous versions of the FW caused ProLiant system fans to operate at improper speeds.


Version:HPD9 (17 Aug 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Resolved an issue with 01/5D/32 error in SMART log.  Read-Write Error Recovery issue may cause HDD to time-out.  Full recovery from this error can take several seconds.

Enhancements

This firmware improves the hard drive servo control which reduces the number of positioning errors. 


Version:HPD5 (21 Jul 2010)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Resolved an issue where the HDD may cease to function and recovery from such a failure would require a power cycle, at a minimum.

Enhancements

Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products


Type: Firmware - SAS Storage Disk
Version: HPD9(17 Aug 2011)
Operating System(s):
Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64

Description

This Windows Smart Component contains a firmware update for the hard drive models EG0146FARTR (146GB 10K SAS 6G) and EG0300FARTT (300GB 10K SAS 6G) in HP P2000 G3 MSA and MSA2000 G2 configurations.

Enhancements

This firmware improves the hard drive servo control which reduces the number of positioning errors. 

Installation Instructions

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

2802195127b1ae67ff75998993be9dc4 cp014547.exe

Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of array controller


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


Notes:

Deliverable Name:

    Firmware Flash Component for Windows - HP P2000/MSA2000 146GB,300GB 10K SAS 6G SFF Hard Drive (EG0146FARTR and EG0300FARTT)

Release Version and/or Date:
      HPD9

Last Recommended or Critical Version:
      HPD5

Previous Version of Firmware:
      HPD5

Firmware Dependency:
     None

Enhancements/New Features:
     This firmware improves the hard drive servo control which reduces the number of positioning errors.

Problems Fixed:
     
   Resolved an issue with 01/5D/32 error in SMART log.  Read-Write Error Recovery issue may cause HDD to time-out.  Full recovery from this error can take several seconds.

Known Issues:
     None

Failure Considerations:

  1. Single ported drive will not be flashed if the owner controller of that drive is not accessible through network.
  2. Drives will not be flashed if the drive is in a virtual disk which is being initialized, expanded, reconstructed, verified, or scrubbed.
  3. Flash operation on any pending disks will be aborted if the currently flashed drive is in LEFTOVR state or the virtual disk containing this disk is found to be in offline or critical state. If this does occur, the vdisk can be restored to online status by changing the drive status from leftover to available and then adding the drive to the vdisk as a spare. If a global spare drive was available, it will have been used to restore the vdisk to online status.

Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any HP P2000 G3 or MSA2000 G2 array controller enclosure.


Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Resolved an issue with 01/5D/32 error in SMART log.  Read-Write Error Recovery issue may cause HDD to time-out.  Full recovery from this error can take several seconds.

Important

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.

Revision History

Version:HPDA (A) (15 Aug 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware HPDA(A) is not necessary if the HDD is currently running HPDA firmware.


The following issue was fixed in HPDA:

  • Firmware now correctly reports the maximum drive recommended operating temperature.  The incorrect values reported in previous versions of the FW caused ProLiant system fans to operate at improper speeds.
Enhancements

In this version the Smart Component was updated to support MSA 1040/2040 arrays.


Version:HPDA (18 May 2012)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Problems Fixed:  

Firmware version HPDA now correctly reports the maximum drive recommended operating temperature.  The incorrect values reported in previous versions of the FW caused ProLiant system fans to operate at improper speeds.


Version:HPD9 (17 Aug 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Resolved an issue with 01/5D/32 error in SMART log.  Read-Write Error Recovery issue may cause HDD to time-out.  Full recovery from this error can take several seconds.

Enhancements

This firmware improves the hard drive servo control which reduces the number of positioning errors. 


Version:HPD5 (21 Jul 2010)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Resolved an issue where the HDD may cease to function and recovery from such a failure would require a power cycle, at a minimum.

Enhancements

Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.