Printable version

Drivers & software

* RECOMMENDED * Moonshot Component Pack 2019.03.01

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware
Version: 2019.03.01(2 Apr 2019)
Operating System(s): CentOS 6
CentOS 7
Citrix XenServer 6.x (x86-64)
Citrix XenServer 7.x (x86-64)
Microsoft Windows 10 (64-bit)
Microsoft Windows 7 (64-bit)
Microsoft Windows 7 Enterprise (32-bit)
Microsoft Windows 7 Enterprise (64-bit)
Microsoft Windows 7 Professional (32-bit)
Microsoft Windows 7 Professional (64-bit)
Microsoft Windows 8.1 (64-bit)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Microsoft Windows Server 2019
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
SUSE Linux Enterprise Server 15
File name: moonshot_component_pack_2019.03.01.zip (223 MB)
Moonshot Component Pack is a comprehensive firmware solution tested on the HP Moonshot System and delivered as a compressed file. The compressed file includes all the component files needed to update a Moonshot System. Users deploy the firmware updates contained in the Moonshot Component Pack via the iLO Chassis Manager CLI or HP Moonshot-45Gc/180Gc Switch Module CLI. The firmware can also be deployed using the Moonshot Firmware Deployment Tool and using the firmware configuration file.

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 

Prerequisites:

For prerequisite information, see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

7e42f36695023837d8a57b33299c3a4e8f1d74f0dd70e0fc9a16737e0a4fc29d moonshot_component_pack_2019.03.01.zip

Reboot Requirement:
Reboot may be required after installation for updates to take effect and hardware stability to be maintained.


Installation:

For detailed information, see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.

 


End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

NOTE: MCP 2019.03.01 replaces MCP 2019.03 which contained m710x Server Cartridge Data firmware version 11, ProLiant_m710x_Server_Cartridge_Data_18Apr2018_ENHC.HPb. This firmware caused the fans on the m710x server blades to rev up and become loud. MCP 2019.03.01 has been updated to include ProLiant_m710x_Server_Cartridge_Data_13Nov2017.hpb which addresses this issue.

Firmware Deployment Change

The MCP Firmware will now be deployed using the Moonshot 1500 Firmware Update Utility which is included in the MCP deliverable. The Moonshot 1500 Firmware Update Utility is a tool for applying firmware to one or more Moonshot 1500 chassis in one session. It currently supports client or server versions of Windows as the Management Workstation from which to deploy firmware. There is no Linux support at this time. To learn more, see Moonshot 1500 Firmware Update Utility.

SUM is no longer included in the MCP. If you wish to deploy the firmware using SUM as was done with previous MCPs, you can use SUM that was included in a previous MCP. The file, cp034504.zip is the file which can be deployed via SUM to update the Moonshot cartridges and blades.

Known Issue: If you wish to use SUM to deploy cp039271.zip to update the Moonshot cartridges and blades, you will need to remove Anders3_16.vme from cp039271.zip before you trying to use SUM. If you don't remove Anders3_16.vme, the update will fail.

Components for the cartridges listed below have been removed from this MCP. MCP 2017.06.0 was the last MCP to contain components for the following cartridges:

  • HP ProLiant Moonshot Server
  • HP ProLiant m800 Server Cartridge
  • HP ProLiant m400 Server Cartridge
  • HP ProLiant m350 Server Cartridge
  • HP ProLiant m300 Server Cartridge

For additional information see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.

Additional Support Documentation can be found in the Moonshot Series Library.

 


Notes:

For a specific list of firmware and software included with this component pack, see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.

For firmware and driver support for specific hardware, go to the following URL, www.hpe.com/support.


Supported Devices and Features:

For supported hardware, see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


MCP 2019.03.01 replaces MCP 2019.03 which contained m710x Server Cartridge Data firmware version 11, ProLiant_m710x_Server_Cartridge_Data_18Apr2018_ENHC.HPb. This firmware caused the fans on the m710x server blades to rev up and become loud. MCP 2019.03.01 has been updated to include ProLiant_m710x_Server_Cartridge_Data_13Nov2017.hpb which addresses this issue.

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

NOTE: MCP 2019.03.01 replaces MCP 2019.03 which contained m710x Server Cartridge Data firmware version 11, ProLiant_m710x_Server_Cartridge_Data_18Apr2018_ENHC.HPb. This firmware caused the fans on the m710x server blades to rev up and become loud. MCP 2019.03.01 has been updated to include ProLiant_m710x_Server_Cartridge_Data_13Nov2017.hpb which addresses this issue.

Firmware Deployment Change

The MCP Firmware will now be deployed using the Moonshot 1500 Firmware Update Utility which is included in the MCP deliverable. The Moonshot 1500 Firmware Update Utility is a tool for applying firmware to one or more Moonshot 1500 chassis in one session. It currently supports client or server versions of Windows as the Management Workstation from which to deploy firmware. There is no Linux support at this time. To learn more, see Moonshot 1500 Firmware Update Utility.

SUM is no longer included in the MCP. If you wish to deploy the firmware using SUM as was done with previous MCPs, you can use SUM that was included in a previous MCP. The file, cp034504.zip is the file which can be deployed via SUM to update the Moonshot cartridges and blades.

Known Issue: If you wish to use SUM to deploy cp039271.zip to update the Moonshot cartridges and blades, you will need to remove Anders3_16.vme from cp039271.zip before you trying to use SUM. If you don't remove Anders3_16.vme, the update will fail.

Components for the cartridges listed below have been removed from this MCP. MCP 2017.06.0 was the last MCP to contain components for the following cartridges:

  • HP ProLiant Moonshot Server
  • HP ProLiant m800 Server Cartridge
  • HP ProLiant m400 Server Cartridge
  • HP ProLiant m350 Server Cartridge
  • HP ProLiant m300 Server Cartridge

For additional information see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.

Additional Support Documentation can be found in the Moonshot Series Library.

 

Version:2019.03.01 (2 Apr 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


MCP 2019.03.01 replaces MCP 2019.03 which contained m710x Server Cartridge Data firmware version 11, ProLiant_m710x_Server_Cartridge_Data_18Apr2018_ENHC.HPb. This firmware caused the fans on the m710x server blades to rev up and become loud. MCP 2019.03.01 has been updated to include ProLiant_m710x_Server_Cartridge_Data_13Nov2017.hpb which addresses this issue.

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2018.02.1 (26 Mar 2018)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

MCP 2018.02.1 contains the following ROM revisions which include the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre:

  • System ROM for HPE ProLiant m510 Server Cartridge (H05)  1.64_01-22-2018
  • System ROM for HP ProLiant m710 Server Cartridge (H03)  2018.01.22
  • System ROM for HP ProLiant m710p Server Cartridge (H06)  2018.01.22
  • System ROM for HPE ProLiant m710x Server Cartridge (H07)  1.64_01-22-2018

Moonshot Component Pack 2018.02.1 replaces Moonshot Component Pack 2018.02.0. MCP 2018.02.1 contains the following ROM revisions which include the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre:

  • System ROM for HPE ProLiant m510 Server Cartridge (H05)  1.64_01-22-2018
  • System ROM for HP ProLiant m710 Server Cartridge (H03)  2018.01.22
  • System ROM for HP ProLiant m710p Server Cartridge (H06)  2018.01.22
  • System ROM for HPE ProLiant m710x Server Cartridge (H07)  1.64_01-22-2018

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2018.02.0 (26 Feb 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2017.08.0 (24 Aug 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2017.06.0 (25 Jun 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2017.04.1 (20 Jun 2017)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

This is an optional update. You can update your Moonshot chassis which contain HPE ProLiant m710x and m710p Server cartridges using deliverables included in this MCP to avoid misreporting thermal data. 


Integrated Lights-Out Chassis Manager Firmware v1.54:

  • Fixed support for Galois/Counter Mode (GCM) ciphers that caused SSL connection failures to clients when used.
  • Fixed Integrated Management Log (IML) thermal entries to show failing temp value (not next sample, which was sometimes misleading).
  • Fixed physical serial port communications hang that could occur while using Virtual Serial Port to a device while connected via the physical serial port of iLO CM.
  • Cartridge UID lights are no longer turned off because of chassis hood presence. 

System ROM for HPE ProLiant m710x Server Cartridge (H07) v1.20_04-24-2017:

  • Improved robustness of collecting thermal data

ProLiant m710x Server Cartridge Data 5/12/2017 v06:

  • Improved robustness of collecting thermal data.

ProLiant m710p Server Cartridge Data 5/15/2017 v051517:

  • Improved robustness of collecting thermal data.

 


Version:2017.04.0 (18 Apr 2017)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Integrated Lights-Out Chassis Manager Firmware v1.53:

  • Managing cartridges when unexpected manufacturing data was encountered on a cartridge.
  • Lack of responsiveness in CLI and GUI that were possible if cartridge flashing or reading firmware revisions was performed during a cartridge aux-power reset.
  • Cartridge REST authentication to properly close sessions to iLO CM after authenticating.  This prevents HTTP 400 errors that were seen if too many sessions were opened too quickly.
  • Issue with sometimes not being able to flash switch firmware after having flashed the Satellite Controller on the switch.
  • Cause of "Network error -5" seen while pulling firmware images from a webserver repetitively.

Integrated Lights-Out (iLO) on Moonshot v2.51:

  • Improved robustness of REST calls to the iLO on cartridge, when in a Moonshot 1500 chassis.
  • Security fix for PSRT 301.
  • The 'Location' header returned in RESTful responses to include the port number if a port was specified on the call to iLO Chassis Manager.

 

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 


Version:2017.02.00 (14 Feb 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED: Moonshot Component Pack version 2017.02.0 is NO LONGER AVAILABLE for download as there are anomalies in the following binaries: iLO_Chassis_Management_Firmware_151.bin and ilo4_250_moonshot.bin. These anamolies are documented in the Customer Advisory, "HPE Moonshot -Setting a Cartridge Asset Tag in a Moonshot 1500 Chassis via iLO Chassis Manager 1.50 or 1.51 May Cause MAC Addresses to Disappear and the Cartridge Asset Tag to Revert to a Previous Value". Replacement MCP version 2017.04.0 and later are available for download. See the Customer Advisory, "HPE Moonshot - FIRMWARE UPDATE RECOMMENDED: Moonshot Component Pack 2017.02.0 Has Been Retired from HPE.com And Replaced with Moonshot Component Pack 2017.04.0 " for more information.

The Moonshot Component Pack Release Notes for version 2017.02.0 have been removed from the Moonshot Series Library. There are versions of Moonshot Component Pack Release Notes for newer versions of the Moonshot Component Pack on the Moonshot Series Library.

 

Enhancements

REMOVED: Moonshot Component Pack version 2017.02.0 is NO LONGER AVAILABLE for download as there are anomalies in the following binaries: iLO_Chassis_Management_Firmware_151.bin and ilo4_250_moonshot.bin. These anamolies are documented in the Customer Advisory, "HPE Moonshot -Setting a Cartridge Asset Tag in a Moonshot 1500 Chassis via iLO Chassis Manager 1.50 or 1.51 May Cause MAC Addresses to Disappear and the Cartridge Asset Tag to Revert to a Previous Value". Replacement MCP version 2017.04.0 and later are available for download. See the Customer Advisory, "HPE Moonshot - FIRMWARE UPDATE RECOMMENDED: Moonshot Component Pack 2017.02.0 Has Been Retired from HPE.com And Replaced with Moonshot Component Pack 2017.04.0 " for more information.

New support included in this release:  

  • HP Smart Update Manager v7.6.0
  • HP ProLiant m700p Server Cartridge

The Moonshot Component Pack Release Notes for version 2017.02.0 have been removed from the Moonshot Series Library. There are versions of Moonshot Component Pack Release Notes for newer versions of the Moonshot Component Pack on the Moonshot Series Library.

 


Version:2016.07.0 (27 Jul 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

New support included in this release:  

  • Smart Update Manager (SUM) v7.5.1
  • Integrated Lights-Out Chassis Manager Firmware v2.40 (a)
  • Integrated Lights-Out Chassis Manager Firmware v1.51
  • iLO Chassis Management Module Programmable Logic Device v07
  • HPE ProLiant m710x Server Cartridge ROM (H07) v1.00_05-23-2016
  • HPE ProLiant m510 Server Cartridge ROM (H05) v2016.5.9
  • HPE ProLiant m710p Server Cartridge ROM (H06) v2016.4.6
  • HP Moonshot-45Gc/45XGc/180XGc Switch Firmware Image v7.1.045, F2428
  • HP Moonshot 45-Port/180-Port Switch Firmware Image v2.0.3.5

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2016.02.0 (25 Feb 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes or the Moonshot Series Library for detailed information on the Fixes for this release.

 

Enhancements

New support included in this release:  

  • iLO Moonshot Remote Console Administrator v 2.31
  • iLO Chassis Manager v1.41
  • ProLiant m700 Server Cartridge M.2 MEZZ Abstraction data v2016.1.8

For additional Enhancements included in this release, see the Moonshot Component Pack Release Notes or the Moonshot Series Library.

 


Version:2015.11.0 (2 Nov 2015)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


See the Moonshot Component Pack Release Notes or the Moonshot Series Library for detailed information on the Fixes for this release.

 

Enhancements

New support included in this release:  

  • Integrated Lights-Out Chassis Manager Firmware v1.40
  • Remote Console Administrator Cartridge Data v10.6.2015
  • HP Smart Update Manager v7.4.0

For additional Enhancements included in this release, see the Moonshot Component Pack Release Notes or the Moonshot Series Library.

 


Version:2015.05.0 (9 May 2015)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixes:

iLO Chassis Management Firmware v1.31:

  • Fixed storage wear level calculation.  Storage device with >1% wear could potentially show with a critical health status and Integrated Management Log (IML) entries.
  • Fixed potential speed fluctuations in a chassis with m400 or m700 cartridges.

Cartridge Satellite Firmware v2015.03.13:

  • Fixed an issue where an open Virtual Serial Port (VSP) session to a HP Moonshot-45G or Moonshot-180G switch module failed to display the switch module boot messages and initial command prompt following a switch module boot or reboot when iLO Chassis Manager 1.20 or later was used.

System ROM for HP ProLiant Moonshot Cartridge (h01) v2015.02.23:

  • Updated to eliminate the "row hammer" issue when susceptible DIMMs have been installed in the server.  This BIOS update will program the memory controller for 2x memory refresh which prevents the "row hammer" issue that could result in correctable or uncorrectable memory errors.

System ROM for HP ProLiant m400 Server Cartridge (U02) v2015.02.26:

  • Updated to eliminate the "row hammer" issue when susceptible DIMMs have been installed in the server.  This BIOS update will program the memory controller for 2x memory refresh which prevents the "row hammer" issue that could result in correctable or uncorrectable memory errors.

HP ProLiant m400 Server Cartridge Programmable Logic Device vOBOB:

  • Fixed a rare instance in which CPU shutdown occurs due to overheat when iLO CM did not have the opportunity to gracefully shut the system down.  The iLO CM would inaccurately still report that CPU was on and healthy when the CPU had turned off due to overtemp.

System ROM for HP ProLiant m710 Server Cartridge (h03) v2015.04.30:

  • Updated to eliminate the "row hammer" issue when susceptible DIMMs have been installed in the server.  This BIOS update will program the memory controller for 2x memory refresh which prevents the "row hammer" issue that could result in correctable or uncorrectable memory errors.
  • Adjusted the SMBIOS type 2 to have more specific location information about the node.  The "Location in Chassis" field will follow "cXnY".

HP Moonshot-45XGc Switch Firmware Image v7.1.045, Release 2417 (Additional Support Documentation can be found at: HP Moonshot Series Library):

  • Fixed an issue when using stacking with VLAN routing and LAG, sometimes the management processor would not receive ARP responses from the gateway.
  • Fixed an issue when using in-band management, ARP replies sent through the service port may confuse MAC address resolution and prevent access to the switch.
  • Changed the behavior of LLDP Chassis ID TLV to not send the same MAC address from every port on the switch as this confuses some topology management software.  The switch now sends the interface name for this TLV.
  • Fixed an issue where the switch module would unexpectedly reboot when trying to upload configuration data to a Macintosh-based SSH server. 

HP Moonshot 45-Port/180-Port Switch Firmware Image v2.0.3.0:

  • Fixed an issue when using stacking with VLAN routing and LAG, sometimes the management processor would not receive ARP responses from the gateway.
  • Fixed an issue when using in-band management, ARP replies sent through the service port may confuse MAC address resolution and prevent access to the switch.
  • Changed the behavior of LLDP Chassis ID TLV to not send the same MAC address from every port on the switch as this confuses some topology management software.  The switch now sends the interface name for this TLV.
  • Fixed an issue where the switch module would unexpectedly reboot when trying to upload configuration data to a Macintosh-based SSH server. 

 

For additional information see the HP Moonshot Component Pack Release Notes 

Enhancements

A Supplement Bundle for the Moonshot Component Pack v2015.05.0 was released on 9/4/15 to include the following. 

  • System ROM for HP ProLiant m400 (U02) v215.07.09
  • HP ProLiant m400 Cartridge Data v03/31/2015
  • m400 SLIMpro Firmware v03/16/2015
  • HPb image for HP m400 Ethernet 10Gb 2 Port 544+i Adapter v 2.32.5340
  • System ROM for HP ProLiant m710p (H06) v2015.06.19

This Supplement Bundle is designed to be used as a supplement to, and in conjunction with, the Moonshot Component Pack v2015.05.0. It can be downloaded at: https://downloads.hpe.com/pub/softlib2/software1/component-fw/p1293395042/v112341

Enhancements for Moonshot Component Pack v2015.05.0 includes the following:

New support:  HP Smart Update Manager v7.2.0

HP Moonshot 1500 Chassis Firmware v4.7.6:

  • Added support for HP 1500W Common Slot -48VDC Hot Plug Power Supply Kit.

System ROM for HP ProLiant m400 Server Cartridge (U02) v2015.02.26:

  • Add support for Linux 3.17.

System ROM for HP ProLiant m710 Server Cartridge (h03) v2015.04.30:

  • Adjusted the SMBIOS type 2 to have more specific location information about the node.  The "Location in Chassis" field follows "cXnY".

HP Moonshot-45XGc Switch Firmware Image v7.1.045, Release 2417 (Additional Support Documentation can be found at: HP Moonshot Series Library):

  • Added support for running PXE when dynamic LAG is configured to a server cartridge with a teamed NIC.
  • Added support for remapping VLAN 4094 to an arbitrary MST instance.
  • Enhanced the pre-boot utility menu to disallow invalid actions that could allow one to accidentally render the switch unusable.

HP Moonshot 45-Port/180-Port Switch Firmware Image v2.0.3.0:

  • Added support for running PXE when dynamic LAG is configured to a server cartridge with a teamed NIC.
  • Added support for remapping VLAN 4094 to an arbitrary MST instance.
  • Enhanced the pre-boot utility menu to disallow invalid actions that could allow one to accidentally render the switch unusable.

HP Moonshot-45XGc Switch Module Cartridge Data File v0128.15:

  • Added switch features record.
  • Enables both VSP and console serial ports 

 

For additional information see the HP Moonshot Component Pack Release Notes 


Version:2014.12.0 (17 Dec 2014)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


HP Moonshot 45-Port / 180-Port Switch firmware Image v2.0.2.3:

  • Link/LED behavior when using 1G RJ45 SFP module.
  • MAC address and IPv6 address reporting.

HP ProLiant m700 Server Cartridge Data v10.31.2014:

  • Temperature sensors 10-16 powered off node 1 only.

HP ProLiant m700 Server Cartridge iSSD Mezz Data v10.31.2014:

  • Temperature sensors 10-16 powered off node 1 only.

HP ProLiant m300 Server Cartridge Data v11.11.2014:

  • The ProLiant m300 cartridge data will not show more than one NIC uplink per HP Moonshot-180G Switch Module in mix chassis configurations.

HP ProLiant m350 Server Cartridge NGFF Data v11.24.2014:

  • The thermal limit to start ramping fans for M.2 modules was set too high.

For additional information see the HP Moonshot Component Pack Release Notes



     
Enhancements

HP Moonshot 45-Port / 180-Port Switch firmware Image v2.0.2.3:

  • Enhanced messaging during CPLD update.
  • Improved messaging when enabling/disabling of VSP.
  • Improved messaging on console port when VSP is enabled.
  • Added auto-negotiate functionality to QSFP+ ports.

System ROM for HP ProLiant m710 Server Cartridge (H03) v2014.12.11:

  • Enabled server cartridge to support mixed or matched cartridge configurations.

System ROM for HP ProLiant m710 Cartridge Data v10-31-214:

  • Added SRIO linking supported bits in the abstraction data and also change asset table to support SRIO linking.

HP m710 Ethernet 10Gb 2 Port 544+i Adapter v2.32.5210

  • IMPORTANT - Before using any method to apply this update, you must power off the node.

System ROM for HP ProLiant m800 Server Cartridge (U01) v2014.10.04:

  • Added support for Serial Rapid IO packet forwarding with ppa:ti-keystone-team/keystone-hpc-3.0.1.5.

HP ProLiant m800 Server Cartridge Data v10.31.2014:

  • Add SRIO linking supported bits in the abstraction data and also change asset table.

HP ProLiant m800 Server Cartridge M.2 Mezz Data v10.31.2014:

  • Add changes to support SRIO linking feature.

For additional information see the HP Moonshot Component Pack Release Notes 



     

Version:2014.11.0 (13 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


iLO Chassis Management Firmware v1.30:

  • Boot Once configuration was being preserved after a cartridge was removed and reinserted, but it was reported as N/A.  When the cartridge booted next it would boot to the Boot Once device that had been previously configured.
  • SET CHASSIS ASSET, SET CHASSIS AUTOPOWER, SET CHASSIS NAME, and SET FACTORY DEFAULT cause boot options to be lost.
  • SET FACTORY DEFAULT did not properly initialize the default boot device setting.
  • SET NODE BOOT could modify the Boot Once configuration.
  • VSP sometimes drops characters when a large buffer is pasted into the input.
  • SHOW CHASSIS POWER STATUS inaccurately reflects status when a power supply is removed.
  • The IPv6 address of Switch Remote Management interfaces in SHOW CHASSIS INFO and SHOW SWITCH INFO is improperly formatted.
  • Security fix for SSRT101745.
Cartridge Satellite Firmware v2014.10.01:
  • An HP ProLiant server cartridge might not power on and the Moonshot 1500 CM module might not recognize it for up to 9 minutes after installation or when power is first applied to the Moonshot 1500 Chassis.
HP Moonshot 1500 Chassis Firmware v4.6:
  • Erroneous IML entries related to power supply failure or installation were recorded.
  • Cartridge nodes in certain cartridge locations with power capping configured were not throttling correctly for three seconds after a power supply is removed.
System ROM for HP ProLiant m300 Series Server Cartridge (H02) v2014.08.28:
  • Linux DMSG may report an ACPI warning message.
System ROM for HP ProLiant m700 Server Cartridge (A34) v2014.10.02:
  • AN MIF engine issue degraded iLO CM firmware drive information command functionality.
System ROM for HP ProLiant m710 Server Cartridge (H03) v2014.10.09:
  • A POST error caused a halt on reboot when using M.2 boot devices.
  • An error prevented automatic installation of Red Hat Enterprise Linux 6 Server Update 5.
System ROM for HP ProLiant m800 Server Cartridge (U01) v2014.10.01:
  • A rare issue could cause the network controller to stop functioning or report errors.

Enhancements

New support for the following HP Server Cartridges and HP Smart Update Manager v7.1.0

  • HP ProLiant m400 Server Cartridge

iLO Chassis Management Firmware v1.30:

  • Added the Moonshot Web Interface, accessed over HTTPS using the hostname or IP address of the Moonshot chassis.
  • Added User SSH key-based authentication
  • Added SNMP trap support.
  • Added the PING command.
  • Modified the SET CHASSIS POWERCAP MODE command to include support for a new powercap mode (Power Feed Redundancy).
  • Modified the UPDATE FIRMWARE command to flash up to three cartridges at a time.
  • Updated the following command output to include additional information:
    • SHOW NODE INFO - Now includes drive information on supported cartridges 
    • SHOW SWITCH INFO - Now includes uplink module information.
    • SHOW FRU - Now includes uplink module information.
  • Modified the required privilege level of the following commands to allow all users:
    • SHOW ALERTMAIL SETTINGS
    • SHOW SYSLOG SETTINGS
    • SHOW CHASSIS BACKUP

HP Moonshot 1500 Chassis Firmware v4.6:

  • Added support for new power capping mode.

HP Moonshot-45-Port/180-Port Switch Module Firmware Image v2.0.0.19:

  • Increased the number of supported ports in a LAG to 256.
  • Added 1G support on 4QSFP+uplink ports.
  • Added CLI command CR4 AUTONEG.

HP ProLiant m300 Cartridge Server ROM (A34) v2014.08.28:

  • Increased storage device information reporting to the iLO CM firmware.

HP ProLiant m710 Cartridge Server ROM (H03) v2014.10.01:

  • Added JSON support for hyperthreading configuration.

 

 


For additional information see the HP Moonshot Component Pack Release Notes 

 


Version:2014.09.0 (29 Sep 2014)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Cartridge Satellite Firmware v2014.08.20:

  • Addressed an issue where Intelligent Platform Management Interface (IPMI) may not be available for Nodes 2, 3, and 4 on multi-node ARM based cartridges.
System ROM for HP ProLiant m700 Server Cartridge (A34) v2014.09.03:
  • Resolved an issue where an operating system may report fewer than the expected number of processor cores.

Enhancements

New support for the following HP Server Cartridges and HP Smart Update Manager v7.1.0.0:

  • HP ProLiant m350 Server Cartridge
  • HP ProLiant m710 Server Cartridge
  • HP ProLiant m800 Server Cartridge


System ROM for HP ProLiant m700 Server Cartridge (A34) 2014.09.03:

  • Enhanced settings to allow continued full performance operation at higher temperatures


HP Moonshot 45-Port/180-Port Switch Module Firmware Image v2.0.0.16: 

  • Changed default user accounts to remove the guest account
  • Added support for future server cartridges


For detailed information see the HP Moonshot Component Pack Release Notes

 

 

 


Version:2014.08.0 (21 Aug 2014)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


System ROM for HP ProLiant m300 server cartridge (H02) 2014.06.24: 

  • Fixed a rare issue to ensure the server cartridge does not become unresponsive during POST, with no indication of failure from the BIOS Serial Console.
  • Fixed the BIOS Serial Console so that serial output and key control work properly during Operating System installation.
Enhancements

System ROM for HP ProLiant m300 server cartridge (H02) 2014.06.24: 

  • Added support to allow the cartridge BIOS Serial Console connection to the iLO Chassis Manager to be disabled at the end of POST.


HP ProLiant m300 Server Cartridge Data v5_27_2014:

  •  EEPROM:
    • ISCSI support
    • Error reporting
    • BSCR enable


For additional information see the HP Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide.

Additional Support Documentation can be found at: HP Moonshot Series Library


Version:2014.06.0 (30 Jun 2014)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Integrated Lights-Out Chassis Management Firmware 1.20:

  • Fixed potential VSP failures when connecting/disconnecting multiple times.
  • Suppressed fan spin up when powering down, removing and reinserting a cartridge
  • Fixed problem with accessing switch VSP after flashing the switch satellite controller
  • Fixed potential failure in clear log IML <Cx> command if the log was wrapped
  • Fixed IPMI access of boot option settings
  • Fixed problems with IPMI under high activity
  • Fixed IML log entry count in show log IML <start date><end date>
  • Fixed problems and SSH becoming unresponsive
  • Fixed occasional erroneous "Cartridge not installed" status
Cartridge Satellite Firmware 2014.05.20:
  • Resolved conditions that could result in the satellite controller becoming unresponsive to iLO Chassis Management Firmware.
HP Moonshot 1500 Chassis Firmware v4.4:
  • Fixed an issue where chassis power reporting was incorrect.
  • Fixed an issue where chassis power was too low when the power supply was removed from slot.

HP Moonshot 1500 Chassis Programmable Logic Device v0B0B:
  • Fixed an issue where the iLO Network internal management switches could lose communication in the presence of unstable AC power.



Enhancements

Release Summary:

New support:

  • HP Smart Update Manager (HP SUM)  6.5.0

iLO Chassis Management Firmware v1.20:

  • Enhanced the SET NODE command to include:
    • CLI option for enabling or disabling BIOS Serial Console (BSC)
    • CLI option for CPU speed setting (CPU)
    • Added boot/bootonce selections for M.2 and iSCSI
    • Added optional secondary boot device control
    • Show current BOOTONCE setting in SHOW NODE OPTIONS.  This allows you to determine if there is a BOOTONCE setting pending that would affect the next boot.
  • Added alerting, using Alertmail and Remote Syslog.
  • Increased the maximum number of simultaneous SSH sessions to 45.  NOTE:  A maximum of 10 SSH VSP sessions are supported at a time.
  • Increased the maximum size of CM scripts from 2k to 16k.
  • Added UDP flow control for VSP, increasing the reliability of VSP for those cartridges that support hardware flow control.
  • Added automatic disaster recovery for the iLO CM firmware. The iLO CM firmware now recovers from corrupted flash images caused by power loss during the iLO CM firmware flash process.
  • Added the CLEAR CHASSIS BACKUP command to clear the configuration data from the baseboard.  This is intended for use before replacing the baseboard. Alternatively, SET FACTORY DEFAULT will clear the chassis backup information.
  • Updated the output of the SHOW CARTRIDGE INFO command to include a node count.
  • Modified CONNECT NODE VSP to ignore missing cartridges or inapplicable nodes in the range specified on the command line. This allows the user to specify, for example, a convenient range for multi-node collated VSP without the command failing because a node in the range was not present.
  • Changed the privilege level of many commands from Administrator to Operator to give a wider range of users access to common tasks.
  • Modified the iLO log to record all node power on and off events.
  • Updated System ROM revisions to include the ROM family along with the ROM date.
  • Improved the help for syntax errors. For example, if a command requires a cartridge or node as a target and that is omitted, the missing cartridge or node error is displayed along with the help for the command.

Cartridge Satellite Firmware v2014.05.20:

  • Added end-to-end Virtual Serial Port session flow control for cartridges incorporating the necessary hardware support.  Note that this requires Integrated Lights-Out Chassis Management Firmware v1.20 or later.
  • Optimize firmware now updates faster.
  • Altered session behavior to avoid entering the Alt-SysRq menu at undesired times in Linux console sessions.

HP Moonshot 1500 Chassis Firmware v4.4:

  • Added power supply FRU data validation.


HP Moonshot-180G Switch Module Cartridge Data File v1206.13 and HP Moonshot-45G Switch Module Cartridge Data File v1206.13:

  • Removed the requirement for the force parameter when updating abstraction file.
  • Updated to support the new features of iLO Chassis Manager Firmware v1.20


System ROM for HP ProLiant m700 server cartridge (A34) 2014.05.24: 

  • Updated POST error messages.
  • Added support for enhanced boot options configured through Moonshot iLO CM firmware v1.20.
  • Changed the date and time display to only be visible when Moonshot iLO CM firmware has a valid time.
  • Added Wake On LAN support
  • Optimized PCIe extended configuration space to save memory


For detailed information see the HP Moonshot Component Pack Release Notes
 

 

 


Version:2013.12.0 (20 Dec 2013)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


HP Moonshot 1500 Chassis Firmware v4.3:

  • The chassis serial number and the product SKU would not update correctly in the SL Advanced Power Manager.
  • The chassis fans were incorrectly reported as missing while the fans were present.
  • The system had an infrequent reduction of performance for short durations causing spurious logs in the OS.
HP Moonshot-45G Switch Module Cartridge Data File v1029.13:
  • Switch reboots unexpectedly during a satellite controller reboot
HP Moonshot 45-Port/180-Port Switch Module Firmware Image v2.0.0.13:
  • UID did not blink when flashing the firmware.
  • The uplink module did not power off when the iLO Chassis Manager firmware CLI power off command was entered.
  • Switch rebooted unexpectedly during satellite controller reboot.
  • PHY errata caused link flap on uplink ports.
 System ROM for HP ProLiant Moonshot Cartridge (H01) v2013.11.15:
  • Updated firmware flash filename to match the product name for easy identification. 
     
Enhancements

New support for the following HP Server Cartridges and Switch:

  • HP ProLiant m700 Server Cartridge
  • HP ProLiant m300 Server Cartridge
  • HP Moonshot-180G Switch Module 

Added new operating system support:

  • Microsoft Windows Server 2012 - All Editions
  • Microsoft Windows Server 2012 R2
  • Microsoft Windows 7 Enterprise (x64)
  • Ubuntu 13.10 

iLO Chassis Management Firmware v1.11:

  • The iLO Chassis Manager is now accessible from a single IP address that fully manages all zones and switches. Previously, there were four IP addresses, each providing access to a single zone or the switches. Access through the serial port also now provides direct access to all devices, and the zone commands have been removed. The CLI is the same regardless of the access method you use (SSH or serial port).

Cartridge Satellite Firmware v2013.10.18:

  • Updated to support the new features of iLO Chassis Manager Firmware v1.11

HP Moonshot 1500 Chassis Firmware v4.3:

  • Improved power measurement and power capping accuracy.
  • Added support for the HP 1500W Common Slot Platinum Plus Power Supplies.
  • Added support for additional modes of Power Capping (Modes 0,1,2 now supported) – Requires iLO CM Firmware Version 1.11 or greater to configure.

HP Moonshot-45G Switch Module Cartridge Data File v1029.13:

  • Added warning message when updating abstraction file.
  • Added requirement for force parameter when updating abstraction file.
  • Added support for iLO Chassis Manager Firmware v1.11 Enhancements

HP Moonshot 45-Port/180-Port Switch Module Firmware Image v2.0.0.13: 

  • Added the ability to update the switch firmware through the iLO Chassis Manager firmware CLI (not available when upgrading from 1.0.0.17 or 1.0.0.20 to 2.0.0.13; for future releases only).
  • Added support for additional cartridge types.
  • Added iLO Chassis Manager virtual serial port (VSP) support.
  • Enhanced the security of firmware delivery.
  • Added the switch CLI show CPLD versions command, to display the switch CPLD versions.
  • Added QSFP+ support (only for HP Moonshot-180G Switch Module)


For detailed information see the HP Moonshot Component Pack Release Notes
 


Type: Firmware
Version: 2019.03.01(2 Apr 2019)
Operating System(s):
CentOS 6
CentOS 7
Citrix XenServer 6.x (x86-64)
Citrix XenServer 7.x (x86-64)
Microsoft Windows 10 (64-bit)
Microsoft Windows 7 (64-bit)
Microsoft Windows 7 Enterprise (32-bit)
Microsoft Windows 7 Enterprise (64-bit)
Microsoft Windows 7 Professional (32-bit)
Microsoft Windows 7 Professional (64-bit)
Microsoft Windows 8.1 (64-bit)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Microsoft Windows Server 2019
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
SUSE Linux Enterprise Server 15

Description

Moonshot Component Pack is a comprehensive firmware solution tested on the HP Moonshot System and delivered as a compressed file. The compressed file includes all the component files needed to update a Moonshot System. Users deploy the firmware updates contained in the Moonshot Component Pack via the iLO Chassis Manager CLI or HP Moonshot-45Gc/180Gc Switch Module CLI. The firmware can also be deployed using the Moonshot Firmware Deployment Tool and using the firmware configuration file.

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 

Installation Instructions

Prerequisites:

For prerequisite information, see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

7e42f36695023837d8a57b33299c3a4e8f1d74f0dd70e0fc9a16737e0a4fc29d moonshot_component_pack_2019.03.01.zip

Reboot Requirement:
Reboot may be required after installation for updates to take effect and hardware stability to be maintained.


Installation:

For detailed information, see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.

 


Release Notes

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

NOTE: MCP 2019.03.01 replaces MCP 2019.03 which contained m710x Server Cartridge Data firmware version 11, ProLiant_m710x_Server_Cartridge_Data_18Apr2018_ENHC.HPb. This firmware caused the fans on the m710x server blades to rev up and become loud. MCP 2019.03.01 has been updated to include ProLiant_m710x_Server_Cartridge_Data_13Nov2017.hpb which addresses this issue.

Firmware Deployment Change

The MCP Firmware will now be deployed using the Moonshot 1500 Firmware Update Utility which is included in the MCP deliverable. The Moonshot 1500 Firmware Update Utility is a tool for applying firmware to one or more Moonshot 1500 chassis in one session. It currently supports client or server versions of Windows as the Management Workstation from which to deploy firmware. There is no Linux support at this time. To learn more, see Moonshot 1500 Firmware Update Utility.

SUM is no longer included in the MCP. If you wish to deploy the firmware using SUM as was done with previous MCPs, you can use SUM that was included in a previous MCP. The file, cp034504.zip is the file which can be deployed via SUM to update the Moonshot cartridges and blades.

Known Issue: If you wish to use SUM to deploy cp039271.zip to update the Moonshot cartridges and blades, you will need to remove Anders3_16.vme from cp039271.zip before you trying to use SUM. If you don't remove Anders3_16.vme, the update will fail.

Components for the cartridges listed below have been removed from this MCP. MCP 2017.06.0 was the last MCP to contain components for the following cartridges:

  • HP ProLiant Moonshot Server
  • HP ProLiant m800 Server Cartridge
  • HP ProLiant m400 Server Cartridge
  • HP ProLiant m350 Server Cartridge
  • HP ProLiant m300 Server Cartridge

For additional information see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.

Additional Support Documentation can be found in the Moonshot Series Library.

 


Notes:

For a specific list of firmware and software included with this component pack, see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.

For firmware and driver support for specific hardware, go to the following URL, www.hpe.com/support.


Supported Devices and Features:

For supported hardware, see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.


Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


MCP 2019.03.01 replaces MCP 2019.03 which contained m710x Server Cartridge Data firmware version 11, ProLiant_m710x_Server_Cartridge_Data_18Apr2018_ENHC.HPb. This firmware caused the fans on the m710x server blades to rev up and become loud. MCP 2019.03.01 has been updated to include ProLiant_m710x_Server_Cartridge_Data_13Nov2017.hpb which addresses this issue.

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Important

NOTE: MCP 2019.03.01 replaces MCP 2019.03 which contained m710x Server Cartridge Data firmware version 11, ProLiant_m710x_Server_Cartridge_Data_18Apr2018_ENHC.HPb. This firmware caused the fans on the m710x server blades to rev up and become loud. MCP 2019.03.01 has been updated to include ProLiant_m710x_Server_Cartridge_Data_13Nov2017.hpb which addresses this issue.

Firmware Deployment Change

The MCP Firmware will now be deployed using the Moonshot 1500 Firmware Update Utility which is included in the MCP deliverable. The Moonshot 1500 Firmware Update Utility is a tool for applying firmware to one or more Moonshot 1500 chassis in one session. It currently supports client or server versions of Windows as the Management Workstation from which to deploy firmware. There is no Linux support at this time. To learn more, see Moonshot 1500 Firmware Update Utility.

SUM is no longer included in the MCP. If you wish to deploy the firmware using SUM as was done with previous MCPs, you can use SUM that was included in a previous MCP. The file, cp034504.zip is the file which can be deployed via SUM to update the Moonshot cartridges and blades.

Known Issue: If you wish to use SUM to deploy cp039271.zip to update the Moonshot cartridges and blades, you will need to remove Anders3_16.vme from cp039271.zip before you trying to use SUM. If you don't remove Anders3_16.vme, the update will fail.

Components for the cartridges listed below have been removed from this MCP. MCP 2017.06.0 was the last MCP to contain components for the following cartridges:

  • HP ProLiant Moonshot Server
  • HP ProLiant m800 Server Cartridge
  • HP ProLiant m400 Server Cartridge
  • HP ProLiant m350 Server Cartridge
  • HP ProLiant m300 Server Cartridge

For additional information see the Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide in the Moonshot Series Library.

Additional Support Documentation can be found in the Moonshot Series Library.

 

Revision History

Version:2019.03.01 (2 Apr 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


MCP 2019.03.01 replaces MCP 2019.03 which contained m710x Server Cartridge Data firmware version 11, ProLiant_m710x_Server_Cartridge_Data_18Apr2018_ENHC.HPb. This firmware caused the fans on the m710x server blades to rev up and become loud. MCP 2019.03.01 has been updated to include ProLiant_m710x_Server_Cartridge_Data_13Nov2017.hpb which addresses this issue.

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2018.02.1 (26 Mar 2018)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

MCP 2018.02.1 contains the following ROM revisions which include the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre:

  • System ROM for HPE ProLiant m510 Server Cartridge (H05)  1.64_01-22-2018
  • System ROM for HP ProLiant m710 Server Cartridge (H03)  2018.01.22
  • System ROM for HP ProLiant m710p Server Cartridge (H06)  2018.01.22
  • System ROM for HPE ProLiant m710x Server Cartridge (H07)  1.64_01-22-2018

Moonshot Component Pack 2018.02.1 replaces Moonshot Component Pack 2018.02.0. MCP 2018.02.1 contains the following ROM revisions which include the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre:

  • System ROM for HPE ProLiant m510 Server Cartridge (H05)  1.64_01-22-2018
  • System ROM for HP ProLiant m710 Server Cartridge (H03)  2018.01.22
  • System ROM for HP ProLiant m710p Server Cartridge (H06)  2018.01.22
  • System ROM for HPE ProLiant m710x Server Cartridge (H07)  1.64_01-22-2018

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2018.02.0 (26 Feb 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2017.08.0 (24 Aug 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2017.06.0 (25 Jun 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2017.04.1 (20 Jun 2017)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

This is an optional update. You can update your Moonshot chassis which contain HPE ProLiant m710x and m710p Server cartridges using deliverables included in this MCP to avoid misreporting thermal data. 


Integrated Lights-Out Chassis Manager Firmware v1.54:

  • Fixed support for Galois/Counter Mode (GCM) ciphers that caused SSL connection failures to clients when used.
  • Fixed Integrated Management Log (IML) thermal entries to show failing temp value (not next sample, which was sometimes misleading).
  • Fixed physical serial port communications hang that could occur while using Virtual Serial Port to a device while connected via the physical serial port of iLO CM.
  • Cartridge UID lights are no longer turned off because of chassis hood presence. 

System ROM for HPE ProLiant m710x Server Cartridge (H07) v1.20_04-24-2017:

  • Improved robustness of collecting thermal data

ProLiant m710x Server Cartridge Data 5/12/2017 v06:

  • Improved robustness of collecting thermal data.

ProLiant m710p Server Cartridge Data 5/15/2017 v051517:

  • Improved robustness of collecting thermal data.

 


Version:2017.04.0 (18 Apr 2017)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Integrated Lights-Out Chassis Manager Firmware v1.53:

  • Managing cartridges when unexpected manufacturing data was encountered on a cartridge.
  • Lack of responsiveness in CLI and GUI that were possible if cartridge flashing or reading firmware revisions was performed during a cartridge aux-power reset.
  • Cartridge REST authentication to properly close sessions to iLO CM after authenticating.  This prevents HTTP 400 errors that were seen if too many sessions were opened too quickly.
  • Issue with sometimes not being able to flash switch firmware after having flashed the Satellite Controller on the switch.
  • Cause of "Network error -5" seen while pulling firmware images from a webserver repetitively.

Integrated Lights-Out (iLO) on Moonshot v2.51:

  • Improved robustness of REST calls to the iLO on cartridge, when in a Moonshot 1500 chassis.
  • Security fix for PSRT 301.
  • The 'Location' header returned in RESTful responses to include the port number if a port was specified on the call to iLO Chassis Manager.

 

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 


Version:2017.02.00 (14 Feb 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED: Moonshot Component Pack version 2017.02.0 is NO LONGER AVAILABLE for download as there are anomalies in the following binaries: iLO_Chassis_Management_Firmware_151.bin and ilo4_250_moonshot.bin. These anamolies are documented in the Customer Advisory, "HPE Moonshot -Setting a Cartridge Asset Tag in a Moonshot 1500 Chassis via iLO Chassis Manager 1.50 or 1.51 May Cause MAC Addresses to Disappear and the Cartridge Asset Tag to Revert to a Previous Value". Replacement MCP version 2017.04.0 and later are available for download. See the Customer Advisory, "HPE Moonshot - FIRMWARE UPDATE RECOMMENDED: Moonshot Component Pack 2017.02.0 Has Been Retired from HPE.com And Replaced with Moonshot Component Pack 2017.04.0 " for more information.

The Moonshot Component Pack Release Notes for version 2017.02.0 have been removed from the Moonshot Series Library. There are versions of Moonshot Component Pack Release Notes for newer versions of the Moonshot Component Pack on the Moonshot Series Library.

 

Enhancements

REMOVED: Moonshot Component Pack version 2017.02.0 is NO LONGER AVAILABLE for download as there are anomalies in the following binaries: iLO_Chassis_Management_Firmware_151.bin and ilo4_250_moonshot.bin. These anamolies are documented in the Customer Advisory, "HPE Moonshot -Setting a Cartridge Asset Tag in a Moonshot 1500 Chassis via iLO Chassis Manager 1.50 or 1.51 May Cause MAC Addresses to Disappear and the Cartridge Asset Tag to Revert to a Previous Value". Replacement MCP version 2017.04.0 and later are available for download. See the Customer Advisory, "HPE Moonshot - FIRMWARE UPDATE RECOMMENDED: Moonshot Component Pack 2017.02.0 Has Been Retired from HPE.com And Replaced with Moonshot Component Pack 2017.04.0 " for more information.

New support included in this release:  

  • HP Smart Update Manager v7.6.0
  • HP ProLiant m700p Server Cartridge

The Moonshot Component Pack Release Notes for version 2017.02.0 have been removed from the Moonshot Series Library. There are versions of Moonshot Component Pack Release Notes for newer versions of the Moonshot Component Pack on the Moonshot Series Library.

 


Version:2016.07.0 (27 Jul 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Fixes for this release.

 

Enhancements

New support included in this release:  

  • Smart Update Manager (SUM) v7.5.1
  • Integrated Lights-Out Chassis Manager Firmware v2.40 (a)
  • Integrated Lights-Out Chassis Manager Firmware v1.51
  • iLO Chassis Management Module Programmable Logic Device v07
  • HPE ProLiant m710x Server Cartridge ROM (H07) v1.00_05-23-2016
  • HPE ProLiant m510 Server Cartridge ROM (H05) v2016.5.9
  • HPE ProLiant m710p Server Cartridge ROM (H06) v2016.4.6
  • HP Moonshot-45Gc/45XGc/180XGc Switch Firmware Image v7.1.045, F2428
  • HP Moonshot 45-Port/180-Port Switch Firmware Image v2.0.3.5

See the Moonshot Component Pack Release Notes in the Moonshot Series Library for information on the Enhancements for this release.

 


Version:2016.02.0 (25 Feb 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


See the Moonshot Component Pack Release Notes or the Moonshot Series Library for detailed information on the Fixes for this release.

 

Enhancements

New support included in this release:  

  • iLO Moonshot Remote Console Administrator v 2.31
  • iLO Chassis Manager v1.41
  • ProLiant m700 Server Cartridge M.2 MEZZ Abstraction data v2016.1.8

For additional Enhancements included in this release, see the Moonshot Component Pack Release Notes or the Moonshot Series Library.

 


Version:2015.11.0 (2 Nov 2015)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


See the Moonshot Component Pack Release Notes or the Moonshot Series Library for detailed information on the Fixes for this release.

 

Enhancements

New support included in this release:  

  • Integrated Lights-Out Chassis Manager Firmware v1.40
  • Remote Console Administrator Cartridge Data v10.6.2015
  • HP Smart Update Manager v7.4.0

For additional Enhancements included in this release, see the Moonshot Component Pack Release Notes or the Moonshot Series Library.

 


Version:2015.05.0 (9 May 2015)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixes:

iLO Chassis Management Firmware v1.31:

  • Fixed storage wear level calculation.  Storage device with >1% wear could potentially show with a critical health status and Integrated Management Log (IML) entries.
  • Fixed potential speed fluctuations in a chassis with m400 or m700 cartridges.

Cartridge Satellite Firmware v2015.03.13:

  • Fixed an issue where an open Virtual Serial Port (VSP) session to a HP Moonshot-45G or Moonshot-180G switch module failed to display the switch module boot messages and initial command prompt following a switch module boot or reboot when iLO Chassis Manager 1.20 or later was used.

System ROM for HP ProLiant Moonshot Cartridge (h01) v2015.02.23:

  • Updated to eliminate the "row hammer" issue when susceptible DIMMs have been installed in the server.  This BIOS update will program the memory controller for 2x memory refresh which prevents the "row hammer" issue that could result in correctable or uncorrectable memory errors.

System ROM for HP ProLiant m400 Server Cartridge (U02) v2015.02.26:

  • Updated to eliminate the "row hammer" issue when susceptible DIMMs have been installed in the server.  This BIOS update will program the memory controller for 2x memory refresh which prevents the "row hammer" issue that could result in correctable or uncorrectable memory errors.

HP ProLiant m400 Server Cartridge Programmable Logic Device vOBOB:

  • Fixed a rare instance in which CPU shutdown occurs due to overheat when iLO CM did not have the opportunity to gracefully shut the system down.  The iLO CM would inaccurately still report that CPU was on and healthy when the CPU had turned off due to overtemp.

System ROM for HP ProLiant m710 Server Cartridge (h03) v2015.04.30:

  • Updated to eliminate the "row hammer" issue when susceptible DIMMs have been installed in the server.  This BIOS update will program the memory controller for 2x memory refresh which prevents the "row hammer" issue that could result in correctable or uncorrectable memory errors.
  • Adjusted the SMBIOS type 2 to have more specific location information about the node.  The "Location in Chassis" field will follow "cXnY".

HP Moonshot-45XGc Switch Firmware Image v7.1.045, Release 2417 (Additional Support Documentation can be found at: HP Moonshot Series Library):

  • Fixed an issue when using stacking with VLAN routing and LAG, sometimes the management processor would not receive ARP responses from the gateway.
  • Fixed an issue when using in-band management, ARP replies sent through the service port may confuse MAC address resolution and prevent access to the switch.
  • Changed the behavior of LLDP Chassis ID TLV to not send the same MAC address from every port on the switch as this confuses some topology management software.  The switch now sends the interface name for this TLV.
  • Fixed an issue where the switch module would unexpectedly reboot when trying to upload configuration data to a Macintosh-based SSH server. 

HP Moonshot 45-Port/180-Port Switch Firmware Image v2.0.3.0:

  • Fixed an issue when using stacking with VLAN routing and LAG, sometimes the management processor would not receive ARP responses from the gateway.
  • Fixed an issue when using in-band management, ARP replies sent through the service port may confuse MAC address resolution and prevent access to the switch.
  • Changed the behavior of LLDP Chassis ID TLV to not send the same MAC address from every port on the switch as this confuses some topology management software.  The switch now sends the interface name for this TLV.
  • Fixed an issue where the switch module would unexpectedly reboot when trying to upload configuration data to a Macintosh-based SSH server. 

 

For additional information see the HP Moonshot Component Pack Release Notes 

Enhancements

A Supplement Bundle for the Moonshot Component Pack v2015.05.0 was released on 9/4/15 to include the following. 

  • System ROM for HP ProLiant m400 (U02) v215.07.09
  • HP ProLiant m400 Cartridge Data v03/31/2015
  • m400 SLIMpro Firmware v03/16/2015
  • HPb image for HP m400 Ethernet 10Gb 2 Port 544+i Adapter v 2.32.5340
  • System ROM for HP ProLiant m710p (H06) v2015.06.19

This Supplement Bundle is designed to be used as a supplement to, and in conjunction with, the Moonshot Component Pack v2015.05.0. It can be downloaded at: https://downloads.hpe.com/pub/softlib2/software1/component-fw/p1293395042/v112341

Enhancements for Moonshot Component Pack v2015.05.0 includes the following:

New support:  HP Smart Update Manager v7.2.0

HP Moonshot 1500 Chassis Firmware v4.7.6:

  • Added support for HP 1500W Common Slot -48VDC Hot Plug Power Supply Kit.

System ROM for HP ProLiant m400 Server Cartridge (U02) v2015.02.26:

  • Add support for Linux 3.17.

System ROM for HP ProLiant m710 Server Cartridge (h03) v2015.04.30:

  • Adjusted the SMBIOS type 2 to have more specific location information about the node.  The "Location in Chassis" field follows "cXnY".

HP Moonshot-45XGc Switch Firmware Image v7.1.045, Release 2417 (Additional Support Documentation can be found at: HP Moonshot Series Library):

  • Added support for running PXE when dynamic LAG is configured to a server cartridge with a teamed NIC.
  • Added support for remapping VLAN 4094 to an arbitrary MST instance.
  • Enhanced the pre-boot utility menu to disallow invalid actions that could allow one to accidentally render the switch unusable.

HP Moonshot 45-Port/180-Port Switch Firmware Image v2.0.3.0:

  • Added support for running PXE when dynamic LAG is configured to a server cartridge with a teamed NIC.
  • Added support for remapping VLAN 4094 to an arbitrary MST instance.
  • Enhanced the pre-boot utility menu to disallow invalid actions that could allow one to accidentally render the switch unusable.

HP Moonshot-45XGc Switch Module Cartridge Data File v0128.15:

  • Added switch features record.
  • Enables both VSP and console serial ports 

 

For additional information see the HP Moonshot Component Pack Release Notes 


Version:2014.12.0 (17 Dec 2014)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


HP Moonshot 45-Port / 180-Port Switch firmware Image v2.0.2.3:

  • Link/LED behavior when using 1G RJ45 SFP module.
  • MAC address and IPv6 address reporting.

HP ProLiant m700 Server Cartridge Data v10.31.2014:

  • Temperature sensors 10-16 powered off node 1 only.

HP ProLiant m700 Server Cartridge iSSD Mezz Data v10.31.2014:

  • Temperature sensors 10-16 powered off node 1 only.

HP ProLiant m300 Server Cartridge Data v11.11.2014:

  • The ProLiant m300 cartridge data will not show more than one NIC uplink per HP Moonshot-180G Switch Module in mix chassis configurations.

HP ProLiant m350 Server Cartridge NGFF Data v11.24.2014:

  • The thermal limit to start ramping fans for M.2 modules was set too high.

For additional information see the HP Moonshot Component Pack Release Notes



     
Enhancements

HP Moonshot 45-Port / 180-Port Switch firmware Image v2.0.2.3:

  • Enhanced messaging during CPLD update.
  • Improved messaging when enabling/disabling of VSP.
  • Improved messaging on console port when VSP is enabled.
  • Added auto-negotiate functionality to QSFP+ ports.

System ROM for HP ProLiant m710 Server Cartridge (H03) v2014.12.11:

  • Enabled server cartridge to support mixed or matched cartridge configurations.

System ROM for HP ProLiant m710 Cartridge Data v10-31-214:

  • Added SRIO linking supported bits in the abstraction data and also change asset table to support SRIO linking.

HP m710 Ethernet 10Gb 2 Port 544+i Adapter v2.32.5210

  • IMPORTANT - Before using any method to apply this update, you must power off the node.

System ROM for HP ProLiant m800 Server Cartridge (U01) v2014.10.04:

  • Added support for Serial Rapid IO packet forwarding with ppa:ti-keystone-team/keystone-hpc-3.0.1.5.

HP ProLiant m800 Server Cartridge Data v10.31.2014:

  • Add SRIO linking supported bits in the abstraction data and also change asset table.

HP ProLiant m800 Server Cartridge M.2 Mezz Data v10.31.2014:

  • Add changes to support SRIO linking feature.

For additional information see the HP Moonshot Component Pack Release Notes 



     

Version:2014.11.0 (13 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


iLO Chassis Management Firmware v1.30:

  • Boot Once configuration was being preserved after a cartridge was removed and reinserted, but it was reported as N/A.  When the cartridge booted next it would boot to the Boot Once device that had been previously configured.
  • SET CHASSIS ASSET, SET CHASSIS AUTOPOWER, SET CHASSIS NAME, and SET FACTORY DEFAULT cause boot options to be lost.
  • SET FACTORY DEFAULT did not properly initialize the default boot device setting.
  • SET NODE BOOT could modify the Boot Once configuration.
  • VSP sometimes drops characters when a large buffer is pasted into the input.
  • SHOW CHASSIS POWER STATUS inaccurately reflects status when a power supply is removed.
  • The IPv6 address of Switch Remote Management interfaces in SHOW CHASSIS INFO and SHOW SWITCH INFO is improperly formatted.
  • Security fix for SSRT101745.
Cartridge Satellite Firmware v2014.10.01:
  • An HP ProLiant server cartridge might not power on and the Moonshot 1500 CM module might not recognize it for up to 9 minutes after installation or when power is first applied to the Moonshot 1500 Chassis.
HP Moonshot 1500 Chassis Firmware v4.6:
  • Erroneous IML entries related to power supply failure or installation were recorded.
  • Cartridge nodes in certain cartridge locations with power capping configured were not throttling correctly for three seconds after a power supply is removed.
System ROM for HP ProLiant m300 Series Server Cartridge (H02) v2014.08.28:
  • Linux DMSG may report an ACPI warning message.
System ROM for HP ProLiant m700 Server Cartridge (A34) v2014.10.02:
  • AN MIF engine issue degraded iLO CM firmware drive information command functionality.
System ROM for HP ProLiant m710 Server Cartridge (H03) v2014.10.09:
  • A POST error caused a halt on reboot when using M.2 boot devices.
  • An error prevented automatic installation of Red Hat Enterprise Linux 6 Server Update 5.
System ROM for HP ProLiant m800 Server Cartridge (U01) v2014.10.01:
  • A rare issue could cause the network controller to stop functioning or report errors.

Enhancements

New support for the following HP Server Cartridges and HP Smart Update Manager v7.1.0

  • HP ProLiant m400 Server Cartridge

iLO Chassis Management Firmware v1.30:

  • Added the Moonshot Web Interface, accessed over HTTPS using the hostname or IP address of the Moonshot chassis.
  • Added User SSH key-based authentication
  • Added SNMP trap support.
  • Added the PING command.
  • Modified the SET CHASSIS POWERCAP MODE command to include support for a new powercap mode (Power Feed Redundancy).
  • Modified the UPDATE FIRMWARE command to flash up to three cartridges at a time.
  • Updated the following command output to include additional information:
    • SHOW NODE INFO - Now includes drive information on supported cartridges 
    • SHOW SWITCH INFO - Now includes uplink module information.
    • SHOW FRU - Now includes uplink module information.
  • Modified the required privilege level of the following commands to allow all users:
    • SHOW ALERTMAIL SETTINGS
    • SHOW SYSLOG SETTINGS
    • SHOW CHASSIS BACKUP

HP Moonshot 1500 Chassis Firmware v4.6:

  • Added support for new power capping mode.

HP Moonshot-45-Port/180-Port Switch Module Firmware Image v2.0.0.19:

  • Increased the number of supported ports in a LAG to 256.
  • Added 1G support on 4QSFP+uplink ports.
  • Added CLI command CR4 AUTONEG.

HP ProLiant m300 Cartridge Server ROM (A34) v2014.08.28:

  • Increased storage device information reporting to the iLO CM firmware.

HP ProLiant m710 Cartridge Server ROM (H03) v2014.10.01:

  • Added JSON support for hyperthreading configuration.

 

 


For additional information see the HP Moonshot Component Pack Release Notes 

 


Version:2014.09.0 (29 Sep 2014)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Cartridge Satellite Firmware v2014.08.20:

  • Addressed an issue where Intelligent Platform Management Interface (IPMI) may not be available for Nodes 2, 3, and 4 on multi-node ARM based cartridges.
System ROM for HP ProLiant m700 Server Cartridge (A34) v2014.09.03:
  • Resolved an issue where an operating system may report fewer than the expected number of processor cores.

Enhancements

New support for the following HP Server Cartridges and HP Smart Update Manager v7.1.0.0:

  • HP ProLiant m350 Server Cartridge
  • HP ProLiant m710 Server Cartridge
  • HP ProLiant m800 Server Cartridge


System ROM for HP ProLiant m700 Server Cartridge (A34) 2014.09.03:

  • Enhanced settings to allow continued full performance operation at higher temperatures


HP Moonshot 45-Port/180-Port Switch Module Firmware Image v2.0.0.16: 

  • Changed default user accounts to remove the guest account
  • Added support for future server cartridges


For detailed information see the HP Moonshot Component Pack Release Notes

 

 

 


Version:2014.08.0 (21 Aug 2014)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


System ROM for HP ProLiant m300 server cartridge (H02) 2014.06.24: 

  • Fixed a rare issue to ensure the server cartridge does not become unresponsive during POST, with no indication of failure from the BIOS Serial Console.
  • Fixed the BIOS Serial Console so that serial output and key control work properly during Operating System installation.
Enhancements

System ROM for HP ProLiant m300 server cartridge (H02) 2014.06.24: 

  • Added support to allow the cartridge BIOS Serial Console connection to the iLO Chassis Manager to be disabled at the end of POST.


HP ProLiant m300 Server Cartridge Data v5_27_2014:

  •  EEPROM:
    • ISCSI support
    • Error reporting
    • BSCR enable


For additional information see the HP Moonshot Component Pack Release Notes or the Moonshot Component Pack Update Guide.

Additional Support Documentation can be found at: HP Moonshot Series Library


Version:2014.06.0 (30 Jun 2014)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Integrated Lights-Out Chassis Management Firmware 1.20:

  • Fixed potential VSP failures when connecting/disconnecting multiple times.
  • Suppressed fan spin up when powering down, removing and reinserting a cartridge
  • Fixed problem with accessing switch VSP after flashing the switch satellite controller
  • Fixed potential failure in clear log IML <Cx> command if the log was wrapped
  • Fixed IPMI access of boot option settings
  • Fixed problems with IPMI under high activity
  • Fixed IML log entry count in show log IML <start date><end date>
  • Fixed problems and SSH becoming unresponsive
  • Fixed occasional erroneous "Cartridge not installed" status
Cartridge Satellite Firmware 2014.05.20:
  • Resolved conditions that could result in the satellite controller becoming unresponsive to iLO Chassis Management Firmware.
HP Moonshot 1500 Chassis Firmware v4.4:
  • Fixed an issue where chassis power reporting was incorrect.
  • Fixed an issue where chassis power was too low when the power supply was removed from slot.

HP Moonshot 1500 Chassis Programmable Logic Device v0B0B:
  • Fixed an issue where the iLO Network internal management switches could lose communication in the presence of unstable AC power.



Enhancements

Release Summary:

New support:

  • HP Smart Update Manager (HP SUM)  6.5.0

iLO Chassis Management Firmware v1.20:

  • Enhanced the SET NODE command to include:
    • CLI option for enabling or disabling BIOS Serial Console (BSC)
    • CLI option for CPU speed setting (CPU)
    • Added boot/bootonce selections for M.2 and iSCSI
    • Added optional secondary boot device control
    • Show current BOOTONCE setting in SHOW NODE OPTIONS.  This allows you to determine if there is a BOOTONCE setting pending that would affect the next boot.
  • Added alerting, using Alertmail and Remote Syslog.
  • Increased the maximum number of simultaneous SSH sessions to 45.  NOTE:  A maximum of 10 SSH VSP sessions are supported at a time.
  • Increased the maximum size of CM scripts from 2k to 16k.
  • Added UDP flow control for VSP, increasing the reliability of VSP for those cartridges that support hardware flow control.
  • Added automatic disaster recovery for the iLO CM firmware. The iLO CM firmware now recovers from corrupted flash images caused by power loss during the iLO CM firmware flash process.
  • Added the CLEAR CHASSIS BACKUP command to clear the configuration data from the baseboard.  This is intended for use before replacing the baseboard. Alternatively, SET FACTORY DEFAULT will clear the chassis backup information.
  • Updated the output of the SHOW CARTRIDGE INFO command to include a node count.
  • Modified CONNECT NODE VSP to ignore missing cartridges or inapplicable nodes in the range specified on the command line. This allows the user to specify, for example, a convenient range for multi-node collated VSP without the command failing because a node in the range was not present.
  • Changed the privilege level of many commands from Administrator to Operator to give a wider range of users access to common tasks.
  • Modified the iLO log to record all node power on and off events.
  • Updated System ROM revisions to include the ROM family along with the ROM date.
  • Improved the help for syntax errors. For example, if a command requires a cartridge or node as a target and that is omitted, the missing cartridge or node error is displayed along with the help for the command.

Cartridge Satellite Firmware v2014.05.20:

  • Added end-to-end Virtual Serial Port session flow control for cartridges incorporating the necessary hardware support.  Note that this requires Integrated Lights-Out Chassis Management Firmware v1.20 or later.
  • Optimize firmware now updates faster.
  • Altered session behavior to avoid entering the Alt-SysRq menu at undesired times in Linux console sessions.

HP Moonshot 1500 Chassis Firmware v4.4:

  • Added power supply FRU data validation.


HP Moonshot-180G Switch Module Cartridge Data File v1206.13 and HP Moonshot-45G Switch Module Cartridge Data File v1206.13:

  • Removed the requirement for the force parameter when updating abstraction file.
  • Updated to support the new features of iLO Chassis Manager Firmware v1.20


System ROM for HP ProLiant m700 server cartridge (A34) 2014.05.24: 

  • Updated POST error messages.
  • Added support for enhanced boot options configured through Moonshot iLO CM firmware v1.20.
  • Changed the date and time display to only be visible when Moonshot iLO CM firmware has a valid time.
  • Added Wake On LAN support
  • Optimized PCIe extended configuration space to save memory


For detailed information see the HP Moonshot Component Pack Release Notes
 

 

 


Version:2013.12.0 (20 Dec 2013)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


HP Moonshot 1500 Chassis Firmware v4.3:

  • The chassis serial number and the product SKU would not update correctly in the SL Advanced Power Manager.
  • The chassis fans were incorrectly reported as missing while the fans were present.
  • The system had an infrequent reduction of performance for short durations causing spurious logs in the OS.
HP Moonshot-45G Switch Module Cartridge Data File v1029.13:
  • Switch reboots unexpectedly during a satellite controller reboot
HP Moonshot 45-Port/180-Port Switch Module Firmware Image v2.0.0.13:
  • UID did not blink when flashing the firmware.
  • The uplink module did not power off when the iLO Chassis Manager firmware CLI power off command was entered.
  • Switch rebooted unexpectedly during satellite controller reboot.
  • PHY errata caused link flap on uplink ports.
 System ROM for HP ProLiant Moonshot Cartridge (H01) v2013.11.15:
  • Updated firmware flash filename to match the product name for easy identification. 
     
Enhancements

New support for the following HP Server Cartridges and Switch:

  • HP ProLiant m700 Server Cartridge
  • HP ProLiant m300 Server Cartridge
  • HP Moonshot-180G Switch Module 

Added new operating system support:

  • Microsoft Windows Server 2012 - All Editions
  • Microsoft Windows Server 2012 R2
  • Microsoft Windows 7 Enterprise (x64)
  • Ubuntu 13.10 

iLO Chassis Management Firmware v1.11:

  • The iLO Chassis Manager is now accessible from a single IP address that fully manages all zones and switches. Previously, there were four IP addresses, each providing access to a single zone or the switches. Access through the serial port also now provides direct access to all devices, and the zone commands have been removed. The CLI is the same regardless of the access method you use (SSH or serial port).

Cartridge Satellite Firmware v2013.10.18:

  • Updated to support the new features of iLO Chassis Manager Firmware v1.11

HP Moonshot 1500 Chassis Firmware v4.3:

  • Improved power measurement and power capping accuracy.
  • Added support for the HP 1500W Common Slot Platinum Plus Power Supplies.
  • Added support for additional modes of Power Capping (Modes 0,1,2 now supported) – Requires iLO CM Firmware Version 1.11 or greater to configure.

HP Moonshot-45G Switch Module Cartridge Data File v1029.13:

  • Added warning message when updating abstraction file.
  • Added requirement for force parameter when updating abstraction file.
  • Added support for iLO Chassis Manager Firmware v1.11 Enhancements

HP Moonshot 45-Port/180-Port Switch Module Firmware Image v2.0.0.13: 

  • Added the ability to update the switch firmware through the iLO Chassis Manager firmware CLI (not available when upgrading from 1.0.0.17 or 1.0.0.20 to 2.0.0.13; for future releases only).
  • Added support for additional cartridge types.
  • Added iLO Chassis Manager virtual serial port (VSP) support.
  • Enhanced the security of firmware delivery.
  • Added the switch CLI show CPLD versions command, to display the switch CPLD versions.
  • Added QSFP+ support (only for HP Moonshot-180G Switch Module)


For detailed information see the HP Moonshot Component Pack Release Notes
 


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.