Printable version

Drivers & software

** CRITICAL ** Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - Storage Controller
Version: 2.65(13 Mar 2020)
Operating System(s): VMware ESXi 7.0
VMware vSphere 6.0
VMware vSphere 6.5
VMware vSphere 6.7
Multi-part download
File name: CP043368.compsig (2.2 KB)
File name: CP043368.zip (14 MB)
This Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408e-m, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

ef3ad180fb7f15f879ff70a2653e92d590efea4e0ef7d531842987d228dfc7fd CP043368.zip
f83c34a2e43e5955157037833f07ca8314d09ce977d77e13e2c3c61ed5efa612 CP043368.compsig

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

 

To use Smart Update Manager from the Service Pack for ProLiant:

     Offline (
The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components):

  • Place the Service Pack for ProLiant on a USB key using the USB Key Utility for Windows.
  • Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.
  • Boot from the newly created Service Pack for ProLiant USB key.
  • Follow Smart Update Manager steps to complete firmware update.

     Remote Online:

  • Download the appropriate SPP.
  • Add the component to the SPP.
  • Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.
  • Run SUM.
  • Add the ESXi host to be updated as a remote target/node.
  • Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).
  • For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.
  • Follow Smart Update Manager Steps and complete the firmware update.

Refer to the SPP documentation for detailed instructions at: http://www.hpe.com/info/spp/documentation
 
To use HP Insight Control for vCenter:

  • Log in to the vSphere Client.
  • Select a server or cluster in the inventory tree.
  • Click the HP Insight Management tab.
  • Follow Insight Control for vCenter steps to update firmware using a Smart Component

To update firmware from VMware ESXi operating system on target server:

  • Enable Tech Support Mode on the ESXi host.
  • Login as root. (You must be root in order to apply the update.)
  • Place the Smart Component zip file in a temporary directory.
  • Unzip the file CPXXXXXX.zip
  • Ensure that CPXXXXXX.vmexe is executable by using the command:

             chmod +x CPXXXXXX.vmexe    

  • From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe
  • Follow the directions given by the Smart Component.
  • Logout
  • Disable Tech Support Mode on the ESXi host.

 


End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Notes:

Deliverable Name:
     Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10

Release Version and/or Date:
  2.65 

Previous Version of Firmware:
     None

Firmware Dependency:
     None

Enhancements/New Features:    

None

Problems Fixed:     

  • Prevents a potential data inconsistency from occurring after experiencing an Unrecoverable Read Error (URE) on a drive configured in RAID 1/10/ADM Fault Tolerant Mode.
  • Prevents a potential data inconsistency from occurring during initial configuration and operation of a volume configured in RAID 5/6/50/60 Fault Tolerant Mode.

o   For additional information, reference Customer Bulletin a00097210en_us.

IMPORTANT: RAID 0 and Unassigned drives are not affected.

 


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • Prevents a potential data inconsistency from occurring after experiencing an Unrecoverable Read Error (URE) on a drive configured in RAID 1/10/ADM Fault Tolerant Mode.
  • Prevents a potential data inconsistency from occurring during initial configuration and operation of a volume configured in RAID 5/6/50/60 Fault Tolerant Mode.

o   For additional information regarding Compute and Storage platforms, reference Customer Bulletin a00097210en_us.

  • HPE does NOT recommend independently updating to Firmware Versions Newer than 1.99 for HPE Smart Array SR Gen10 Controllers on HPE SimpliVity Gen10 systems.
    For additional information regarding SimpliVity platforms, reference Customer Bulletin a00097566en_us

 

IMPORTANT: RAID 0 and drives in HBA Mode are not affected.

Version:2.65(A) (29 Apr 2020)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Prevents a potential data inconsistency from occurring after experiencing an Unrecoverable Read Error (URE) on a drive configured in RAID 1/10/ADM Fault Tolerant Mode.
  • Prevents a potential data inconsistency from occurring during initial configuration and operation of a volume configured in RAID 5/6/50/60 Fault Tolerant Mode.

o   For additional information, reference Customer Bulletin a00097210en_us.

IMPORTANT: RAID 0 and Unassigned drives are not affected.

Enhancements

Added support for ESXi 7.0


Version:2.65 (13 Mar 2020)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • Prevents a potential data inconsistency from occurring after experiencing an Unrecoverable Read Error (URE) on a drive configured in RAID 1/10/ADM Fault Tolerant Mode.
  • Prevents a potential data inconsistency from occurring during initial configuration and operation of a volume configured in RAID 5/6/50/60 Fault Tolerant Mode.

o   For additional information regarding Compute and Storage platforms, reference Customer Bulletin a00097210en_us.

  • HPE does NOT recommend independently updating to Firmware Versions Newer than 1.99 for HPE Smart Array SR Gen10 Controllers on HPE SimpliVity Gen10 systems.
    For additional information regarding SimpliVity platforms, reference Customer Bulletin a00097566en_us

 

IMPORTANT: RAID 0 and drives in HBA Mode are not affected.


Version:2.62 (20 Dec 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED -  Firmware version 2.62 is NO LONGER AVAILABLE for download. Review HPE Customer Bulletin a00097210en_us for additional information that includes replacement firmware version.

 

Fixes the following unexpected behaviors:

  • Controller could stop responding with a 0x1A91 message during active path failure when scanning expander indexes.
  • Controller could stop responding during I/O processing and Smart Cache flush process if there is an invalid transient message return by the physical drives.
  • When predictive spare rebuild is triggered on Smart Cache, the rebuilding process could fail to start.
  • Data could become inaccessible when a SATA drive overruns a data transfer
  • Controller memory could become unstable when the response to an Identify Device command (IDD) is received from a drive
  • Communication between the host system and a RAID5/6 volume could potentially fail after an I/O timeout on one of the drives in the array.
  • System could stop responding with a 0x1E30 message when an ATA locked drive is discovered
  • If a command is execute during a drive sanitize operation the controller could stop responding.
Enhancements

  • Add UBM1 Support
  • Support for backup power source charge timeout values from UEFI
  • UBM2 backplane support
  • Drive hotplug support for UBM backplanes

Version:2.02 (10 Sep 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED -  Firmware version 2.02 is NO LONGER AVAILABLE for download. Review HPE Customer Bulletin a00097210en_us for additional information that includes replacement firmware version.

 

Fixes the following unexpected behaviors:

  • Controller could stop responding with a 0x1A91 message during active path failure when scanning expander indexes.
  • Controller could stop responding during I/O processing and Smart Cache flush process if there is an invalid transient message return by the physical drives.
  • When predictive spare rebuild is triggered on Smart Cache, the rebuilding process could fail to start.
  • Data could become inaccessible when a SATA drive overruns a data transfer
  • Controller memory could become unstable when the response to an Identify Device command (IDD) is received from a drive
  • Communication between the host system and a RAID5/6 volume could potentially fail after an I/O timeout on one of the drives in the array.
  • System could stop responding with a 0x1E30 message when an ATA locked drive is discovered
  • If a command is execute during a drive sanitize operation the controller could stop responding.

Version:1.99 (10 Jun 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED -  Firmware version 1.99 is NO LONGER AVAILABLE for download. Review HPE Customer Bulletin a00097210en_us for additional information that includes replacement firmware version..

 

Fixes the following unexpected behaviors:

  • Controller could stop responding with a 0x1A91 message during active path failure when scanning expander indexes.
  • Controller could stop responding during I/O processing and Smart Cache flush process if there is an invalid transient message return by the physical drives.
  • When predictive spare rebuild is triggered on Smart Cache, the rebuilding process could fail to start.
  • Data could become inaccessible when a SATA drive overruns a data transfer
  • Controller memory could become unstable when the response to an Identify Device command (IDD) is received from a drive
  • Communication between the host system and a RAID5/6 volume could potentially fail after an I/O timeout on one of the drives in the array.
  • System could stop responding with a 0x1E30 message when an ATA locked drive is discovered
  • If a command is execute during a drive sanitize operation the controller could stop responding.

Version:1.98 (2 Apr 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED -  Firmware version 1.98 is NO LONGER AVAILABLE for download. Review HPE Customer Bulletin a00097210en_us for additional information that includes replacement firmware version..

 

Fixes the following unexpected behaviors:

  • Controller could stop responding with a 0x1A91 message during active path failure when scanning expander indexes.
  • Controller could stop responding during I/O processing and Smart Cache flush process if there is an invalid transient message return by the physical drives.
  • When predictive spare rebuild is triggered on Smart Cache, the rebuilding process could fail to start.
  • Data could become inaccessible when a SATA drive overruns a data transfer
  • Controller memory could become unstable when the response to an Identify Device command (IDD) is received from a drive
  • Communication between the host system and a RAID5/6 volume could potentially fail after an I/O timeout on one of the drives in the array.
  • System could stop responding with a 0x1E30 message when an ATA locked drive is discovered
  • If a command is execute during a drive sanitize operation the controller could stop responding.

Version:1.65(B) (27 Nov 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Note: If version 1.65 was previously installed, then it is not necessary to upgrade to version 1.65 (B).


  • Added support for VMware vSphere 6.7 OS

Version:1.65 (27 Sep 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • System might stop responding at POST and fail to load an OS. This issue is more likely to occur if System BIOS version is 1.40 or later. However, systems running older BIOS versions could experience this issue also.

Version:1.60 (19 Jul 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Connectivity to HPE D6020 disk enclosures might be lost if connected to multiple servers.
  • In rare cases, data could become unavailable on a RAID 6 (ADG) volume during a rebuild or parity consistency check.
  • Inability to configure unassigned drives if a failed RAID volume was present.
  • After multiple reboots, unassigned drives might be erroneously assigned as spares for configured RAID volumes.
  • System might continuously reboot after splitting a mirrored volume.
  • Volume transformation might fail or not resume after a system reboot.
  • Maximum command queue depth for SATA drives was limited.
  • Controller might stop responding:
    • During power up device discovery. (POST Lockup 0x1ABD or 0x20227)
    • If multiple completions are received for an IO command. (POST Lockup 0x1BE0)
    • If a drive enclosure is power cycled while IO is running. (POST Lockup 0x1C50 or 0x27006)
    • If a drive enclosure is power cycled while a drive is sanitizing. (POST Lockup 0x1E30)
    • When attempting to modify the controller cache settings while IO is running. (POST Lockup 0x1E30)
    • If a drive failed. (POST Lockup 0x27006)
    • When adding or removing drives from a RAID 5 or RAID 50 volume during a rebuild. (POST Lockup 0xFFFFF001)
    • During POST prior to loading an operating system.
    • When Unrecoverable Read Errors (URE’s) are found on drives.
    • When deleting volumes while a rebuild is occurring and URE’s and found.
    • Following completion of Rapid Parity Initialization (RPI) of a new RAID volume.
    • During a volume transformation.
  • A drive undergoing RPI might be presented to the operating system.
  • Controller slot ID might be shown incorrectly in management tools.
  • Incorrect drive bay numbers might be shown in a dual domain configuration.
  • Drive sanitize might report incorrect status information.
  • Status of the Smart Storage Battery might be reported incorrectly.
  • Incorrect POST message 1831 indicating loss of SmartCache data.
  • Incorrect text in POST message 1786.
  • Various scenarios where drive LEDs might not be displayed correctly.
  • The RESTful management interface might fail when attempting to:
    • Change drive write cache configuration.
    • Configure a new RAID volume.
Enhancements

  • Increased SmartCache maximum logical volume size.
  • Added support for SmartCache in UEFI configuration tools.
  • Added the ability to control drive write cache settings.
  • Added the ability to select the drive erase pattern.

Version:1.34(B) (26 Jun 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Note: If version 1.34 was previously installed, then it is not necessary to upgrade to version 1.34 (B).


  • Added support for the HPE Smart Array P408e-m Controller.

Version:1.34 (22 Dec 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Controller might stop responding while handling a drive error.  (POST Lockup 0x27006)
  • Controller might stop responding after a drive hot-removal or hot-insertion.  (POST Lockup codes 0x1EA or 0x15010)
  • Controller might stop responding during a volume expansion or rekey.  (POST Lockup code 0x1E30)
  • Controller might stop responding while performing heavy writes to a RAID 0 or RAID 1 logical drive that has a flash backed write cache enabled.  (POST Lockup 0x1BC0)
  • Various scenarios where drive LEDs might not be displayed correctly.
  • Drives might not be detected after a cold boot.
  • A hot-inserted drive might be immediately reported as failed.
  • A failed or charging HPE Smart Storage Battery might be reported as “missing” in SSA and iLO.
  • The RESTful management interface might be unable to detect physical drives or make configuration changes to the controller.
  • Option to enable “No Battery Write Cache” in SSA is not available if an HPE Smart Storage Battery is not installed.
  • Customer specified read/write controller cache ratio is not honored if “No Battery Write Cache” is enabled.
  • Controller cache might be displayed as temporarily disabled following an unexpected shutdown and subsequent reboot.
  • Unable to modify the controller cache read/write ratio following an unexpected shutdown and subsequent reboot.
  • The controller cache might become disabled when running VMware ESXi 6.0 if the controller and guest OS are configured to use PCI pass-through.
  • If multiple logical volumes are present on the same array, and one of the volumes is rebuilding, the others might be incorrectly marked as failed.
  • A drive at index 0 might incorrectly display as rebuilding if a logical volume on the controller is currently rebuilding.
  • System might hang during power-up or appear unresponsive during runtime if a logical volume composed of SSD’s is created or rebuilding.
  • Negotiated link rate for drives might not be correct.
  • Storage enclosure information for direct attached drives might not be returned correctly in Windows.
  • The HPE SmartCache feature was not available by default on the P816i-a SR Gen10 controller.
Enhancements

  • Support for ATA Sanitize Freeze/Antifreeze Lock.
  • Ability to select boot controller in Legacy BIOS mode with multiple controllers installed.
  • Updated Hard Drive Carrier LED behavior for the HPE ProLiant XL450 Gen10 Server.
  • Ability to set rebuild priorities via the RESTful management interface.
  • Supported settings – High, MediumHigh, Medium, Low

Type: Firmware - Storage Controller
Version: 2.65(13 Mar 2020)
Operating System(s):
VMware ESXi 7.0
VMware vSphere 6.0
VMware vSphere 6.5
VMware vSphere 6.7

Description

This Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408e-m, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

ef3ad180fb7f15f879ff70a2653e92d590efea4e0ef7d531842987d228dfc7fd CP043368.zip
f83c34a2e43e5955157037833f07ca8314d09ce977d77e13e2c3c61ed5efa612 CP043368.compsig

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

 

To use Smart Update Manager from the Service Pack for ProLiant:

     Offline (
The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components):

  • Place the Service Pack for ProLiant on a USB key using the USB Key Utility for Windows.
  • Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.
  • Boot from the newly created Service Pack for ProLiant USB key.
  • Follow Smart Update Manager steps to complete firmware update.

     Remote Online:

  • Download the appropriate SPP.
  • Add the component to the SPP.
  • Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.
  • Run SUM.
  • Add the ESXi host to be updated as a remote target/node.
  • Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).
  • For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.
  • Follow Smart Update Manager Steps and complete the firmware update.

Refer to the SPP documentation for detailed instructions at: http://www.hpe.com/info/spp/documentation
 
To use HP Insight Control for vCenter:

  • Log in to the vSphere Client.
  • Select a server or cluster in the inventory tree.
  • Click the HP Insight Management tab.
  • Follow Insight Control for vCenter steps to update firmware using a Smart Component

To update firmware from VMware ESXi operating system on target server:

  • Enable Tech Support Mode on the ESXi host.
  • Login as root. (You must be root in order to apply the update.)
  • Place the Smart Component zip file in a temporary directory.
  • Unzip the file CPXXXXXX.zip
  • Ensure that CPXXXXXX.vmexe is executable by using the command:

             chmod +x CPXXXXXX.vmexe    

  • From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe
  • Follow the directions given by the Smart Component.
  • Logout
  • Disable Tech Support Mode on the ESXi host.

 


Release Notes

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Notes:

Deliverable Name:
     Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10

Release Version and/or Date:
  2.65 

Previous Version of Firmware:
     None

Firmware Dependency:
     None

Enhancements/New Features:    

None

Problems Fixed:     

  • Prevents a potential data inconsistency from occurring after experiencing an Unrecoverable Read Error (URE) on a drive configured in RAID 1/10/ADM Fault Tolerant Mode.
  • Prevents a potential data inconsistency from occurring during initial configuration and operation of a volume configured in RAID 5/6/50/60 Fault Tolerant Mode.

o   For additional information, reference Customer Bulletin a00097210en_us.

IMPORTANT: RAID 0 and Unassigned drives are not affected.

 


Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • Prevents a potential data inconsistency from occurring after experiencing an Unrecoverable Read Error (URE) on a drive configured in RAID 1/10/ADM Fault Tolerant Mode.
  • Prevents a potential data inconsistency from occurring during initial configuration and operation of a volume configured in RAID 5/6/50/60 Fault Tolerant Mode.

o   For additional information regarding Compute and Storage platforms, reference Customer Bulletin a00097210en_us.

  • HPE does NOT recommend independently updating to Firmware Versions Newer than 1.99 for HPE Smart Array SR Gen10 Controllers on HPE SimpliVity Gen10 systems.
    For additional information regarding SimpliVity platforms, reference Customer Bulletin a00097566en_us

 

IMPORTANT: RAID 0 and drives in HBA Mode are not affected.

Revision History

Version:2.65(A) (29 Apr 2020)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Prevents a potential data inconsistency from occurring after experiencing an Unrecoverable Read Error (URE) on a drive configured in RAID 1/10/ADM Fault Tolerant Mode.
  • Prevents a potential data inconsistency from occurring during initial configuration and operation of a volume configured in RAID 5/6/50/60 Fault Tolerant Mode.

o   For additional information, reference Customer Bulletin a00097210en_us.

IMPORTANT: RAID 0 and Unassigned drives are not affected.

Enhancements

Added support for ESXi 7.0


Version:2.65 (13 Mar 2020)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • Prevents a potential data inconsistency from occurring after experiencing an Unrecoverable Read Error (URE) on a drive configured in RAID 1/10/ADM Fault Tolerant Mode.
  • Prevents a potential data inconsistency from occurring during initial configuration and operation of a volume configured in RAID 5/6/50/60 Fault Tolerant Mode.

o   For additional information regarding Compute and Storage platforms, reference Customer Bulletin a00097210en_us.

  • HPE does NOT recommend independently updating to Firmware Versions Newer than 1.99 for HPE Smart Array SR Gen10 Controllers on HPE SimpliVity Gen10 systems.
    For additional information regarding SimpliVity platforms, reference Customer Bulletin a00097566en_us

 

IMPORTANT: RAID 0 and drives in HBA Mode are not affected.


Version:2.62 (20 Dec 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED -  Firmware version 2.62 is NO LONGER AVAILABLE for download. Review HPE Customer Bulletin a00097210en_us for additional information that includes replacement firmware version.

 

Fixes the following unexpected behaviors:

  • Controller could stop responding with a 0x1A91 message during active path failure when scanning expander indexes.
  • Controller could stop responding during I/O processing and Smart Cache flush process if there is an invalid transient message return by the physical drives.
  • When predictive spare rebuild is triggered on Smart Cache, the rebuilding process could fail to start.
  • Data could become inaccessible when a SATA drive overruns a data transfer
  • Controller memory could become unstable when the response to an Identify Device command (IDD) is received from a drive
  • Communication between the host system and a RAID5/6 volume could potentially fail after an I/O timeout on one of the drives in the array.
  • System could stop responding with a 0x1E30 message when an ATA locked drive is discovered
  • If a command is execute during a drive sanitize operation the controller could stop responding.
Enhancements

  • Add UBM1 Support
  • Support for backup power source charge timeout values from UEFI
  • UBM2 backplane support
  • Drive hotplug support for UBM backplanes

Version:2.02 (10 Sep 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED -  Firmware version 2.02 is NO LONGER AVAILABLE for download. Review HPE Customer Bulletin a00097210en_us for additional information that includes replacement firmware version.

 

Fixes the following unexpected behaviors:

  • Controller could stop responding with a 0x1A91 message during active path failure when scanning expander indexes.
  • Controller could stop responding during I/O processing and Smart Cache flush process if there is an invalid transient message return by the physical drives.
  • When predictive spare rebuild is triggered on Smart Cache, the rebuilding process could fail to start.
  • Data could become inaccessible when a SATA drive overruns a data transfer
  • Controller memory could become unstable when the response to an Identify Device command (IDD) is received from a drive
  • Communication between the host system and a RAID5/6 volume could potentially fail after an I/O timeout on one of the drives in the array.
  • System could stop responding with a 0x1E30 message when an ATA locked drive is discovered
  • If a command is execute during a drive sanitize operation the controller could stop responding.

Version:1.99 (10 Jun 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED -  Firmware version 1.99 is NO LONGER AVAILABLE for download. Review HPE Customer Bulletin a00097210en_us for additional information that includes replacement firmware version..

 

Fixes the following unexpected behaviors:

  • Controller could stop responding with a 0x1A91 message during active path failure when scanning expander indexes.
  • Controller could stop responding during I/O processing and Smart Cache flush process if there is an invalid transient message return by the physical drives.
  • When predictive spare rebuild is triggered on Smart Cache, the rebuilding process could fail to start.
  • Data could become inaccessible when a SATA drive overruns a data transfer
  • Controller memory could become unstable when the response to an Identify Device command (IDD) is received from a drive
  • Communication between the host system and a RAID5/6 volume could potentially fail after an I/O timeout on one of the drives in the array.
  • System could stop responding with a 0x1E30 message when an ATA locked drive is discovered
  • If a command is execute during a drive sanitize operation the controller could stop responding.

Version:1.98 (2 Apr 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


REMOVED -  Firmware version 1.98 is NO LONGER AVAILABLE for download. Review HPE Customer Bulletin a00097210en_us for additional information that includes replacement firmware version..

 

Fixes the following unexpected behaviors:

  • Controller could stop responding with a 0x1A91 message during active path failure when scanning expander indexes.
  • Controller could stop responding during I/O processing and Smart Cache flush process if there is an invalid transient message return by the physical drives.
  • When predictive spare rebuild is triggered on Smart Cache, the rebuilding process could fail to start.
  • Data could become inaccessible when a SATA drive overruns a data transfer
  • Controller memory could become unstable when the response to an Identify Device command (IDD) is received from a drive
  • Communication between the host system and a RAID5/6 volume could potentially fail after an I/O timeout on one of the drives in the array.
  • System could stop responding with a 0x1E30 message when an ATA locked drive is discovered
  • If a command is execute during a drive sanitize operation the controller could stop responding.

Version:1.65(B) (27 Nov 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Note: If version 1.65 was previously installed, then it is not necessary to upgrade to version 1.65 (B).


  • Added support for VMware vSphere 6.7 OS

Version:1.65 (27 Sep 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • System might stop responding at POST and fail to load an OS. This issue is more likely to occur if System BIOS version is 1.40 or later. However, systems running older BIOS versions could experience this issue also.

Version:1.60 (19 Jul 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Connectivity to HPE D6020 disk enclosures might be lost if connected to multiple servers.
  • In rare cases, data could become unavailable on a RAID 6 (ADG) volume during a rebuild or parity consistency check.
  • Inability to configure unassigned drives if a failed RAID volume was present.
  • After multiple reboots, unassigned drives might be erroneously assigned as spares for configured RAID volumes.
  • System might continuously reboot after splitting a mirrored volume.
  • Volume transformation might fail or not resume after a system reboot.
  • Maximum command queue depth for SATA drives was limited.
  • Controller might stop responding:
    • During power up device discovery. (POST Lockup 0x1ABD or 0x20227)
    • If multiple completions are received for an IO command. (POST Lockup 0x1BE0)
    • If a drive enclosure is power cycled while IO is running. (POST Lockup 0x1C50 or 0x27006)
    • If a drive enclosure is power cycled while a drive is sanitizing. (POST Lockup 0x1E30)
    • When attempting to modify the controller cache settings while IO is running. (POST Lockup 0x1E30)
    • If a drive failed. (POST Lockup 0x27006)
    • When adding or removing drives from a RAID 5 or RAID 50 volume during a rebuild. (POST Lockup 0xFFFFF001)
    • During POST prior to loading an operating system.
    • When Unrecoverable Read Errors (URE’s) are found on drives.
    • When deleting volumes while a rebuild is occurring and URE’s and found.
    • Following completion of Rapid Parity Initialization (RPI) of a new RAID volume.
    • During a volume transformation.
  • A drive undergoing RPI might be presented to the operating system.
  • Controller slot ID might be shown incorrectly in management tools.
  • Incorrect drive bay numbers might be shown in a dual domain configuration.
  • Drive sanitize might report incorrect status information.
  • Status of the Smart Storage Battery might be reported incorrectly.
  • Incorrect POST message 1831 indicating loss of SmartCache data.
  • Incorrect text in POST message 1786.
  • Various scenarios where drive LEDs might not be displayed correctly.
  • The RESTful management interface might fail when attempting to:
    • Change drive write cache configuration.
    • Configure a new RAID volume.
Enhancements

  • Increased SmartCache maximum logical volume size.
  • Added support for SmartCache in UEFI configuration tools.
  • Added the ability to control drive write cache settings.
  • Added the ability to select the drive erase pattern.

Version:1.34(B) (26 Jun 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Note: If version 1.34 was previously installed, then it is not necessary to upgrade to version 1.34 (B).


  • Added support for the HPE Smart Array P408e-m Controller.

Version:1.34 (22 Dec 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Controller might stop responding while handling a drive error.  (POST Lockup 0x27006)
  • Controller might stop responding after a drive hot-removal or hot-insertion.  (POST Lockup codes 0x1EA or 0x15010)
  • Controller might stop responding during a volume expansion or rekey.  (POST Lockup code 0x1E30)
  • Controller might stop responding while performing heavy writes to a RAID 0 or RAID 1 logical drive that has a flash backed write cache enabled.  (POST Lockup 0x1BC0)
  • Various scenarios where drive LEDs might not be displayed correctly.
  • Drives might not be detected after a cold boot.
  • A hot-inserted drive might be immediately reported as failed.
  • A failed or charging HPE Smart Storage Battery might be reported as “missing” in SSA and iLO.
  • The RESTful management interface might be unable to detect physical drives or make configuration changes to the controller.
  • Option to enable “No Battery Write Cache” in SSA is not available if an HPE Smart Storage Battery is not installed.
  • Customer specified read/write controller cache ratio is not honored if “No Battery Write Cache” is enabled.
  • Controller cache might be displayed as temporarily disabled following an unexpected shutdown and subsequent reboot.
  • Unable to modify the controller cache read/write ratio following an unexpected shutdown and subsequent reboot.
  • The controller cache might become disabled when running VMware ESXi 6.0 if the controller and guest OS are configured to use PCI pass-through.
  • If multiple logical volumes are present on the same array, and one of the volumes is rebuilding, the others might be incorrectly marked as failed.
  • A drive at index 0 might incorrectly display as rebuilding if a logical volume on the controller is currently rebuilding.
  • System might hang during power-up or appear unresponsive during runtime if a logical volume composed of SSD’s is created or rebuilding.
  • Negotiated link rate for drives might not be correct.
  • Storage enclosure information for direct attached drives might not be returned correctly in Windows.
  • The HPE SmartCache feature was not available by default on the P816i-a SR Gen10 controller.
Enhancements

  • Support for ATA Sanitize Freeze/Antifreeze Lock.
  • Ability to select boot controller in Legacy BIOS mode with multiple controllers installed.
  • Updated Hard Drive Carrier LED behavior for the HPE ProLiant XL450 Gen10 Server.
  • Ability to set rebuild priorities via the RESTful management interface.
  • Supported settings – High, MediumHigh, Medium, Low

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.