** CRITICAL ** Firmware Flash Component for Windows - HP MSA 2040/P2000/MSA2000 900GB, 600GB, 450GB, 300 GB 6G SAS SFF Hard Drives ( EG0900FBLSK, EG0600FBLSH, EG0450FBLSF, EG0300FBLSE )

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD7(13 Dec 2013)
Operating System(s): Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
File name: cp021965.exe (2.8 MB)
This Windows Smart Component contains a firmware update for the hard drive models EG0900FBLSK (900GB 10K 6G SAS), EG0600FBLSH (600GB 10K 6G SAS), EG0450FBLSF (450GB 10K 6G SAS) and EG0300FBLSE (300GB 10K 6G SAS) in HP MSA 2040, P2000 G3 and MSA2000 G2 configurations.

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040/P2000/MSA2000 storage system.

NOTE: Disk drive upgrades on the HP MSA 2040/P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the Array  reference guide.All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log.

IMPORTANT: Please review the failure considerations above before flashing hard drives in HP MSA 2040/P2000/MSA2000 configurations.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

48baafcdd92ad2ed4b2d9ccbe106ab99 cp021965.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of array controller


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Critical - HP requires users update to this version immediately.


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040/P2000/MSA2000 storage system.

NOTE: Disk drive upgrades on the HP MSA 2040/P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the Array reference guide.All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log.

IMPORTANT: Please review the failure considerations above before flashing hard drives in HP MSA 2040/P2000/MSA2000 configurations.


Notes:

Deliverable Name:
     Firmware Flash Component for Windows - HP MSA 2040/P2000/MSA2000 900GB, 600GB, 450GB, 300 GB 6G SAS SFF Hard Drive ( EG0900FBLSK, EG0600FBLSH, EG0450FBLSF, EG0300FBLSE ) .

Release Version :
      HPD7
 


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any HP MSA 2040 or P2000 G3 or MSA2000 array controller enclosure.


Upgrade Requirement:
Critical - HP requires users update to this version immediately.


  • After long-term use, the drive may develop a mechanical condition preventing the heads from fully unloading onto the ramp, potentially causing data loss or mechanical damage after power loss or power cycle. This firmware prevents this condition.
  • Under rare command timing conditions, the drive may abort a write prior to committing data to disk, resulting in data loss. This firmware prevents this condition.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040/P2000/MSA2000 storage system.

NOTE: Disk drive upgrades on the HP MSA 2040/P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the Array reference guide.All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log.

IMPORTANT: Please review the failure considerations above before flashing hard drives in HP MSA 2040/P2000/MSA2000 configurations.

Version:HPD8 (23 Jun 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following fix is added in HPD8 :

  • Hard disk drive firmware HPD8 resolves the issue where HP ProLiant servers would power down due a hard drive overtemp condition that was falsely reported.

Version:HPD7 (13 Dec 2013)
Fixes

Upgrade Requirement:
Critical - HP requires users update to this version immediately.


  • After long-term use, the drive may develop a mechanical condition preventing the heads from fully unloading onto the ramp, potentially causing data loss or mechanical damage after power loss or power cycle. This firmware prevents this condition.
  • Under rare command timing conditions, the drive may abort a write prior to committing data to disk, resulting in data loss. This firmware prevents this condition.

Version:HPD5 (10 Apr 2012)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Added support for EVA.


Version:HPD3 (6 Dec 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Problems Fixed:

This firmware prevents the following:

    Firmware version HPD3 corrects an issue which causes the drive to reset internally when a link is lost due to communication error.  If this issue occurs, it causes aborted commands, which are typically recovered by system error recovery but causes reset entries in the drive error logs and may momentarily slow performance.

Type: Firmware - SAS Storage Disk
Version: HPD7(13 Dec 2013)
Operating System(s):
Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2

Description

This Windows Smart Component contains a firmware update for the hard drive models EG0900FBLSK (900GB 10K 6G SAS), EG0600FBLSH (600GB 10K 6G SAS), EG0450FBLSF (450GB 10K 6G SAS) and EG0300FBLSE (300GB 10K 6G SAS) in HP MSA 2040, P2000 G3 and MSA2000 G2 configurations.

Installation Instructions

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040/P2000/MSA2000 storage system.

NOTE: Disk drive upgrades on the HP MSA 2040/P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the Array  reference guide.All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log.

IMPORTANT: Please review the failure considerations above before flashing hard drives in HP MSA 2040/P2000/MSA2000 configurations.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

48baafcdd92ad2ed4b2d9ccbe106ab99 cp021965.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of array controller


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Critical - HP requires users update to this version immediately.


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040/P2000/MSA2000 storage system.

NOTE: Disk drive upgrades on the HP MSA 2040/P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the Array reference guide.All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log.

IMPORTANT: Please review the failure considerations above before flashing hard drives in HP MSA 2040/P2000/MSA2000 configurations.


Notes:

Deliverable Name:
     Firmware Flash Component for Windows - HP MSA 2040/P2000/MSA2000 900GB, 600GB, 450GB, 300 GB 6G SAS SFF Hard Drive ( EG0900FBLSK, EG0600FBLSH, EG0450FBLSF, EG0300FBLSE ) .

Release Version :
      HPD7
 


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any HP MSA 2040 or P2000 G3 or MSA2000 array controller enclosure.


Fixes

Upgrade Requirement:
Critical - HP requires users update to this version immediately.


  • After long-term use, the drive may develop a mechanical condition preventing the heads from fully unloading onto the ramp, potentially causing data loss or mechanical damage after power loss or power cycle. This firmware prevents this condition.
  • Under rare command timing conditions, the drive may abort a write prior to committing data to disk, resulting in data loss. This firmware prevents this condition.

Important

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040/P2000/MSA2000 storage system.

NOTE: Disk drive upgrades on the HP MSA 2040/P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the Array reference guide.All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log.

IMPORTANT: Please review the failure considerations above before flashing hard drives in HP MSA 2040/P2000/MSA2000 configurations.

Revision History

Version:HPD8 (23 Jun 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following fix is added in HPD8 :

  • Hard disk drive firmware HPD8 resolves the issue where HP ProLiant servers would power down due a hard drive overtemp condition that was falsely reported.

Version:HPD7 (13 Dec 2013)
Fixes

Upgrade Requirement:
Critical - HP requires users update to this version immediately.


  • After long-term use, the drive may develop a mechanical condition preventing the heads from fully unloading onto the ramp, potentially causing data loss or mechanical damage after power loss or power cycle. This firmware prevents this condition.
  • Under rare command timing conditions, the drive may abort a write prior to committing data to disk, resulting in data loss. This firmware prevents this condition.

Version:HPD5 (10 Apr 2012)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Added support for EVA.


Version:HPD3 (6 Dec 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Problems Fixed:

This firmware prevents the following:

    Firmware version HPD3 corrects an issue which causes the drive to reset internally when a link is lost due to communication error.  If this issue occurs, it causes aborted commands, which are typically recovered by system error recovery but causes reset entries in the drive error logs and may momentarily slow performance.