Type: |
Software - System Management |
Version: |
9.40.12.0(19 Feb 2013) |
Operating System(s): |
Oracle Linux 5 (AMD64/EM64T)
|
Oracle Linux 6 (AMD64/EMT64)
|
Red Hat Enterprise Linux 3 (AMD64/EM64T)
|
Red Hat Enterprise Linux 4 (AMD64/EM64T)
|
Red Hat Enterprise Linux 5 Server (x86-64)
|
Red Hat Enterprise Linux 6 Server (x86-64)
|
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
|
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
|
SUSE Linux Enterprise Server 8 (AMD64)
|
SUSE Linux Enterprise Server 9 (AMD64/EM64T)
|
|
Description
The Array Configuration Utility CLI is a commandline-based disk configuration program for Smart Array Controllers and RAID Array Controllers.
Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Installation Instructions
To ensure the integrity of your download, HP recommends verifying your results with
the following MD5 Checksum values:
hpacucli-9.40-12.0.x86_64.rpm |
4c6c5df3f39e82d8e794001dccd1e0af |
hpacucli-9.40-12.0.x86_64.txt |
91b7a6176ff09a90fe7e7339968c40cc |
Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.
Installation:
ACU CLI is distributed using Red Hat Package Manager (RPM) packages.
If there is an older version of ACU CLI installed on the system, please use "rpm -e hpacucli" to remove it first.
Use "rpm -i " to install the application.
Release Notes
End User License Agreements:
Hewlett-Packard End User License Agreement
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Revision History
Version:9.40.12.0 (19 Feb 2013)
Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization
Version:9.30.15.0 (26 Oct 2012)
Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Logical Drive Movement enhancements
Version:9.20.9.0 (4 Sep 2012)
Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Support for Smart Array P721m
Version:9.10.22.0 (4 Jun 2012)
Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for the following controllers:
-
HP Dynamic Smart Array B120i
-
HP Dynamic Smart Array B320i
-
HP Smart Array P822
Now officially supporting and providing native X64 versions in addition to existing 32 bit versions
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:
-
Replace Array
-
Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
-
Heal Array
-
Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.