Printable version

Drivers & software

Agentless Management Service for Windows X64

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Software - System Management
Version: 1.40.0.0(22 Jan 2019)
Operating System(s): Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Microsoft Windows Server 2019
Multi-part download
File name: cp036094.compsig (2.0 KB)
File name: cp036094.exe (9.6 MB)
Provides out of band management system with OS-level Agentless Management information and Active Health System events.

  • Added configurable polling interval option in the registry for Active Health System (AHS) logging of host CPU and Memory utilization:
    • CPU and Memory utilization used to be logged to AHS every minute, thus potentially causing AHS storage to be full.
    • CPU and Memory utilization is now logged to AHS once upon startup, but a registry key can be created to log more if needed.
      Registry key: HKLM\System\HPAMSAHS, Registry value: QuietPeriodInMinutes (DWORD), from 1 minute to 1440 minutes (i.e. 1 day).
  • Added configurable logging feature to generate log files on local host. The default log size will be 64MB, log level will be Informational(1) and file path: %ProgramFiles%\OEM\AMS\Logs.
    The optional log file size, path and level can be modified by changing the registry values at : HKLM\SYSTEM\AMSLOGCFG
  • The AMS control panel applet is updated to support SNMP configurations with iLO CNSA encryption mode as well.

Prerequisites:

The Channel Interface Driver for Windows X64 must be installed prior to this component.

Microsoft SNMP Service must be enabled, if SMA (System Management Assistant) is enabled.


To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

3d81a074ab978872fe0c12f60962f83d8907cb9dc7acced7e7c5b7ccbbec13d1 cp036094.compsig
93c253ef0c1a114c09032198bc788c621dd5a777e710929dc9f05e6b76b2016b cp036094.exe

Reboot Requirement:
Reboot may be required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Place the Smart Component in a temporary directory, then double-click it to run.

Select "Install" to start extracting to a temporary location on the hard drive.

Click the "Install" button to perform the service installation.


End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Important:

iLO Firmware Version:

  • This version of AMS has been tested with iLO 5 firmware version 1.40. It is recommended to install AMS 1.40 on systems with iLO 5 firmware 1.40.

 

About installation and enablement of SMA service:

  • During AMS installation in interactive mode, there is pop up message to selectively install SMA.
    • If Yes is selected, SMA service will be installed and set to running state.
    • If No is selected, SMA service will be installed but the service is not enabled.
  • During AMS installation in silent mode, SMA is installed but the service is not enabled.
  • To enable SMA service at a later time, go to the following folder: %ProgramFiles%\OEM\AMS\Service\ (Typically c:\Program Files\OEM\AMS\Service) and execute "EnableSma.bat /f"
  • IMPORTANT: The SNMP service community name and permission must also be setup. This is not done by “EnableSma.bat”.
  • To disable SMA after it has been enabled, go to the following folder: %ProgramFiles%\OEM\AMS\Service\ (Typically c:\Program Files\OEM\AMS\Service) and execute "DisableSma.bat /f"
  • After installing Windows operating system, make sure all the latest Microsoft Updates are downloaded and installed (wuapp.exe can be launched to start the update process). If this is not done, a critical error may be reported in Windows Event Log, “The Agentless Management Service terminated unexpectedly.”.

 

AMS Control Panel Applet:

  • The AMS control panel applet UI is best displayed on the system when screen resolution is 1280 x 1024 pixels or higher and text size 100%.


Notes:

  • IML events marked as repaired in ILO will not be mirrored in Windows Event Log.
  • If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,  but it cannot be uninstalled.  To uninstall AMS, the Device Guard policy needs to be temporarily disabled.
  • AMS Control Panel applet “SNMP” tab does not show SNMP settings and does not allow test trap generation
      when iLO5 encryption is set to SuiteB NSA mode.  Please use iLO5->Management page as an alternate option.
  • If there is no HPE Smart Array P824 MR controller installed, the ams.exe process may exhibit handle leak as shown in Task Manager. As a workaround, the handle leak can be prevented by deleting or renaming the following file: %ProgramFiles%\OEM\Ams\Service\storelib.dll. For example:
  1. Stop the AMS service by typing “net stop ams” in a command prompt.
  2. Explore to c:\Program Files\OEM\AMS\Service folder.
  3. Rename the file storelib.dll to storelib.dll.bak
  4. Start the AMS service by typing “net start ams” in a command prompt.

Once the file is renamed, the handle count will stop increasing. If an HPE Smart Array P824 MR Controller is later added to the system, the file needs to be restored and AMS service restarted. For example:

  1. Stop the AMS service by typing “net stop ams” in a command prompt.
  2. Explore to c:\Program Files\OEM\AMS\Service folder.
  3. Rename the previously renamed file storelib.dll.bak to storelib.dll.
  4. Start the AMS service by typing “net start ams” in a command prompt.

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Fixed the issue of AMS terminating unexpectedly on module w2kmgams.dll.

The Agentless Management Service may stop unexpectedly with the following error event logged in Windows Application Event Log: Event ID: 1000, Source: Application Error, Faulting Application Name: ams.exe, Faulting Module Name: w2kmgAMS.dll.

  • Fixed the issue of missing nechesasr.sys in HPE Software inventory.

iLO 5 Automatic Server Recovery Driver for Windows Server 2016 and Server 2019 (cp035140.exe) failed to install on Windows Server 2019 OS deployment using Smart Update tool in SPP v2018.11.0.

 

Refer to the following Customer Advisories for details of the critical issues fixed in this release.

•a00065356en_us (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00065356en_us)

•a00065641en_us (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00065641en_us)

iLO Firmware Version:

  • This version of AMS has been tested with iLO 5 firmware version 1.40. It is recommended to install AMS 1.40 on systems with iLO 5 firmware 1.40.

 

About installation and enablement of SMA service:

  • During AMS installation in interactive mode, there is pop up message to selectively install SMA.
    • If Yes is selected, SMA service will be installed and set to running state.
    • If No is selected, SMA service will be installed but the service is not enabled.
  • During AMS installation in silent mode, SMA is installed but the service is not enabled.
  • To enable SMA service at a later time, go to the following folder: %ProgramFiles%\OEM\AMS\Service\ (Typically c:\Program Files\OEM\AMS\Service) and execute "EnableSma.bat /f"
  • IMPORTANT: The SNMP service community name and permission must also be setup. This is not done by “EnableSma.bat”.
  • To disable SMA after it has been enabled, go to the following folder: %ProgramFiles%\OEM\AMS\Service\ (Typically c:\Program Files\OEM\AMS\Service) and execute "DisableSma.bat /f"
  • After installing Windows operating system, make sure all the latest Microsoft Updates are downloaded and installed (wuapp.exe can be launched to start the update process). If this is not done, a critical error may be reported in Windows Event Log, “The Agentless Management Service terminated unexpectedly.”.

 

AMS Control Panel Applet:

  • The AMS control panel applet UI is best displayed on the system when screen resolution is 1280 x 1024 pixels or higher and text size 100%.

Version:1.43.0.0 (14 Apr 2019)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Fixed the AMS handle count increase when there is no HPE Smart Array P824 MR controller installed or when System Center Operations Manager Management Pack is installed.
Enhancements

  • Added support for HPE Synergy 6820C 25/50Gb CNA.

Version:1.40.0.0 (22 Jan 2019)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Fixed the issue of AMS terminating unexpectedly on module w2kmgams.dll.

The Agentless Management Service may stop unexpectedly with the following error event logged in Windows Application Event Log: Event ID: 1000, Source: Application Error, Faulting Application Name: ams.exe, Faulting Module Name: w2kmgAMS.dll.

  • Fixed the issue of missing nechesasr.sys in HPE Software inventory.

iLO 5 Automatic Server Recovery Driver for Windows Server 2016 and Server 2019 (cp035140.exe) failed to install on Windows Server 2019 OS deployment using Smart Update tool in SPP v2018.11.0.

 

Refer to the following Customer Advisories for details of the critical issues fixed in this release.

•a00065356en_us (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00065356en_us)

•a00065641en_us (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00065641en_us)

Enhancements

  • Added configurable polling interval option in the registry for Active Health System (AHS) logging of host CPU and Memory utilization:
    • CPU and Memory utilization used to be logged to AHS every minute, thus potentially causing AHS storage to be full.
    • CPU and Memory utilization is now logged to AHS once upon startup, but a registry key can be created to log more if needed.
      Registry key: HKLM\System\HPAMSAHS, Registry value: QuietPeriodInMinutes (DWORD), from 1 minute to 1440 minutes (i.e. 1 day).
  • Added configurable logging feature to generate log files on local host. The default log size will be 64MB, log level will be Informational(1) and file path: %ProgramFiles%\OEM\AMS\Logs.
    The optional log file size, path and level can be modified by changing the registry values at : HKLM\SYSTEM\AMSLOGCFG
  • The AMS control panel applet is updated to support SNMP configurations with iLO CNSA encryption mode as well.

Version:1.30.0.0(B) (27 Nov 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


None.

Enhancements

Added support for Microsoft Windows Server 2019.


Version:1.30.0.0 (26 Jun 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • AMS service no longer terminates unexpectedly if the server had more than 9 IPV6 addresses.  However, cpqNicIfLogMapIPV6Address OID will only return up to 9 IPV6 addresses.   
  • Traps 1015, 1019,1020 now have correct varbind info, consistent with MIB definitions.
  • When SMA (System Management Assistant) service is stopped or disabled, SMA will no longer respond to SNMP queries with outdated data.
Enhancements

  • Added support for the following IO devices:
    • HPE Synergy 4820C 10/20/25Gb Converged Network Adapter
    • HPE StorFabric CN1200R-T Converged Network Adapter
    • HPE StorFabric CN1300R Converged Network Adapter
    • HPE Synergy 6410C 25/50Gb Ethernet Adapter
    • HPE Ethernet 100Gb 1-port 842QSFP28 Adapter
    • HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter
  • Added the following enhancements to Control Panel Applet:
    • Up to 8 trap destinations are supported in SNMP tab, along with user configuration and SNMPv3 settings
    • SNMP tab is now fully functional if iLO5 encryption is set to HighSecurity or FIPS mode
    • Button options are available to start, stop, enable or disable SMA service
    • GUI options are available to select time format and input the optional periodic test trap interval
    • Help content has expanded
  • SMA (System Management Assistant) service now supports all MIB OIDs and traps generated by iLO5 FW.
  • Added support for System Chassis Class of IML Events in Windows Event Log.
  • iSCSI MIB condition is now available in cpqHoMibHealthStatusArray.
  • AHS (Active Health System) NIC Link records now contain Interface Description string.

Version:1.20.0.0 (5 Feb 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


None

Enhancements

  • Added support for the following device:
    - HPE Smart Array P824i-p MR Adapter (cpqSasHbaModel: sasP824ip(14))
  • Added support for the following MIB OIDs:
    - cpqIdeAtaDiskMaximumOperatingTemp
    - cpqIdeAtaDiskDestructiveOperatingTemp
    - cpqSasLogDrvTable
  • Added support for a new Active Health System (AHS) record: "OS Logical Disk Usage"
  • Added UTF-8 support for Japanese characters to show correctly on iLO GUI
  • Enhanced AMS Control Panel Applet Help content
  • Added button options in AMS Control Panel Applet to start/stop AMS service, or enable/disable SMA service

Version:1.15.0.0(B) (15 Jan 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


none

Enhancements

Added support for Microsoft Windows 10 (64-bit) operating system.


Version:1.15.0.0 (25 Sep 2017)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • The overall network and controller status are no longer shown degraded on iLO GUI when an FC/FCoE port is not connected.
  • AMS no longer terminates intermittently after the service is started on systems with NVMe drives.
  • AMS no longer terminates on systems with Windows Server 2012 R2 and missing KB2919355.
Enhancements

  • AMS extends the default data polling interval from 30 seconds to 2 minutes, consequently CPU utilization increases less frequently.

Version:1.1.0.0 (12 Jul 2017)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Initial release of “Agentless Management Service for Windows X64”


Type: Software - System Management
Version: 1.40.0.0(22 Jan 2019)
Operating System(s):
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Microsoft Windows Server 2019

Description

Provides out of band management system with OS-level Agentless Management information and Active Health System events.

Enhancements

  • Added configurable polling interval option in the registry for Active Health System (AHS) logging of host CPU and Memory utilization:
    • CPU and Memory utilization used to be logged to AHS every minute, thus potentially causing AHS storage to be full.
    • CPU and Memory utilization is now logged to AHS once upon startup, but a registry key can be created to log more if needed.
      Registry key: HKLM\System\HPAMSAHS, Registry value: QuietPeriodInMinutes (DWORD), from 1 minute to 1440 minutes (i.e. 1 day).
  • Added configurable logging feature to generate log files on local host. The default log size will be 64MB, log level will be Informational(1) and file path: %ProgramFiles%\OEM\AMS\Logs.
    The optional log file size, path and level can be modified by changing the registry values at : HKLM\SYSTEM\AMSLOGCFG
  • The AMS control panel applet is updated to support SNMP configurations with iLO CNSA encryption mode as well.

Installation Instructions

Prerequisites:

The Channel Interface Driver for Windows X64 must be installed prior to this component.

Microsoft SNMP Service must be enabled, if SMA (System Management Assistant) is enabled.


To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

3d81a074ab978872fe0c12f60962f83d8907cb9dc7acced7e7c5b7ccbbec13d1 cp036094.compsig
93c253ef0c1a114c09032198bc788c621dd5a777e710929dc9f05e6b76b2016b cp036094.exe

Reboot Requirement:
Reboot may be required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Place the Smart Component in a temporary directory, then double-click it to run.

Select "Install" to start extracting to a temporary location on the hard drive.

Click the "Install" button to perform the service installation.


Release Notes

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Important:

iLO Firmware Version:

  • This version of AMS has been tested with iLO 5 firmware version 1.40. It is recommended to install AMS 1.40 on systems with iLO 5 firmware 1.40.

 

About installation and enablement of SMA service:

  • During AMS installation in interactive mode, there is pop up message to selectively install SMA.
    • If Yes is selected, SMA service will be installed and set to running state.
    • If No is selected, SMA service will be installed but the service is not enabled.
  • During AMS installation in silent mode, SMA is installed but the service is not enabled.
  • To enable SMA service at a later time, go to the following folder: %ProgramFiles%\OEM\AMS\Service\ (Typically c:\Program Files\OEM\AMS\Service) and execute "EnableSma.bat /f"
  • IMPORTANT: The SNMP service community name and permission must also be setup. This is not done by “EnableSma.bat”.
  • To disable SMA after it has been enabled, go to the following folder: %ProgramFiles%\OEM\AMS\Service\ (Typically c:\Program Files\OEM\AMS\Service) and execute "DisableSma.bat /f"
  • After installing Windows operating system, make sure all the latest Microsoft Updates are downloaded and installed (wuapp.exe can be launched to start the update process). If this is not done, a critical error may be reported in Windows Event Log, “The Agentless Management Service terminated unexpectedly.”.

 

AMS Control Panel Applet:

  • The AMS control panel applet UI is best displayed on the system when screen resolution is 1280 x 1024 pixels or higher and text size 100%.


Notes:

  • IML events marked as repaired in ILO will not be mirrored in Windows Event Log.
  • If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,  but it cannot be uninstalled.  To uninstall AMS, the Device Guard policy needs to be temporarily disabled.
  • AMS Control Panel applet “SNMP” tab does not show SNMP settings and does not allow test trap generation
      when iLO5 encryption is set to SuiteB NSA mode.  Please use iLO5->Management page as an alternate option.
  • If there is no HPE Smart Array P824 MR controller installed, the ams.exe process may exhibit handle leak as shown in Task Manager. As a workaround, the handle leak can be prevented by deleting or renaming the following file: %ProgramFiles%\OEM\Ams\Service\storelib.dll. For example:
  1. Stop the AMS service by typing “net stop ams” in a command prompt.
  2. Explore to c:\Program Files\OEM\AMS\Service folder.
  3. Rename the file storelib.dll to storelib.dll.bak
  4. Start the AMS service by typing “net start ams” in a command prompt.

Once the file is renamed, the handle count will stop increasing. If an HPE Smart Array P824 MR Controller is later added to the system, the file needs to be restored and AMS service restarted. For example:

  1. Stop the AMS service by typing “net stop ams” in a command prompt.
  2. Explore to c:\Program Files\OEM\AMS\Service folder.
  3. Rename the previously renamed file storelib.dll.bak to storelib.dll.
  4. Start the AMS service by typing “net start ams” in a command prompt.

Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Fixed the issue of AMS terminating unexpectedly on module w2kmgams.dll.

The Agentless Management Service may stop unexpectedly with the following error event logged in Windows Application Event Log: Event ID: 1000, Source: Application Error, Faulting Application Name: ams.exe, Faulting Module Name: w2kmgAMS.dll.

  • Fixed the issue of missing nechesasr.sys in HPE Software inventory.

iLO 5 Automatic Server Recovery Driver for Windows Server 2016 and Server 2019 (cp035140.exe) failed to install on Windows Server 2019 OS deployment using Smart Update tool in SPP v2018.11.0.

 

Refer to the following Customer Advisories for details of the critical issues fixed in this release.

•a00065356en_us (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00065356en_us)

•a00065641en_us (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00065641en_us)

Important

iLO Firmware Version:

  • This version of AMS has been tested with iLO 5 firmware version 1.40. It is recommended to install AMS 1.40 on systems with iLO 5 firmware 1.40.

 

About installation and enablement of SMA service:

  • During AMS installation in interactive mode, there is pop up message to selectively install SMA.
    • If Yes is selected, SMA service will be installed and set to running state.
    • If No is selected, SMA service will be installed but the service is not enabled.
  • During AMS installation in silent mode, SMA is installed but the service is not enabled.
  • To enable SMA service at a later time, go to the following folder: %ProgramFiles%\OEM\AMS\Service\ (Typically c:\Program Files\OEM\AMS\Service) and execute "EnableSma.bat /f"
  • IMPORTANT: The SNMP service community name and permission must also be setup. This is not done by “EnableSma.bat”.
  • To disable SMA after it has been enabled, go to the following folder: %ProgramFiles%\OEM\AMS\Service\ (Typically c:\Program Files\OEM\AMS\Service) and execute "DisableSma.bat /f"
  • After installing Windows operating system, make sure all the latest Microsoft Updates are downloaded and installed (wuapp.exe can be launched to start the update process). If this is not done, a critical error may be reported in Windows Event Log, “The Agentless Management Service terminated unexpectedly.”.

 

AMS Control Panel Applet:

  • The AMS control panel applet UI is best displayed on the system when screen resolution is 1280 x 1024 pixels or higher and text size 100%.

Revision History

Version:1.43.0.0 (14 Apr 2019)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Fixed the AMS handle count increase when there is no HPE Smart Array P824 MR controller installed or when System Center Operations Manager Management Pack is installed.
Enhancements

  • Added support for HPE Synergy 6820C 25/50Gb CNA.

Version:1.40.0.0 (22 Jan 2019)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Fixed the issue of AMS terminating unexpectedly on module w2kmgams.dll.

The Agentless Management Service may stop unexpectedly with the following error event logged in Windows Application Event Log: Event ID: 1000, Source: Application Error, Faulting Application Name: ams.exe, Faulting Module Name: w2kmgAMS.dll.

  • Fixed the issue of missing nechesasr.sys in HPE Software inventory.

iLO 5 Automatic Server Recovery Driver for Windows Server 2016 and Server 2019 (cp035140.exe) failed to install on Windows Server 2019 OS deployment using Smart Update tool in SPP v2018.11.0.

 

Refer to the following Customer Advisories for details of the critical issues fixed in this release.

•a00065356en_us (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00065356en_us)

•a00065641en_us (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00065641en_us)

Enhancements

  • Added configurable polling interval option in the registry for Active Health System (AHS) logging of host CPU and Memory utilization:
    • CPU and Memory utilization used to be logged to AHS every minute, thus potentially causing AHS storage to be full.
    • CPU and Memory utilization is now logged to AHS once upon startup, but a registry key can be created to log more if needed.
      Registry key: HKLM\System\HPAMSAHS, Registry value: QuietPeriodInMinutes (DWORD), from 1 minute to 1440 minutes (i.e. 1 day).
  • Added configurable logging feature to generate log files on local host. The default log size will be 64MB, log level will be Informational(1) and file path: %ProgramFiles%\OEM\AMS\Logs.
    The optional log file size, path and level can be modified by changing the registry values at : HKLM\SYSTEM\AMSLOGCFG
  • The AMS control panel applet is updated to support SNMP configurations with iLO CNSA encryption mode as well.

Version:1.30.0.0(B) (27 Nov 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


None.

Enhancements

Added support for Microsoft Windows Server 2019.


Version:1.30.0.0 (26 Jun 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • AMS service no longer terminates unexpectedly if the server had more than 9 IPV6 addresses.  However, cpqNicIfLogMapIPV6Address OID will only return up to 9 IPV6 addresses.   
  • Traps 1015, 1019,1020 now have correct varbind info, consistent with MIB definitions.
  • When SMA (System Management Assistant) service is stopped or disabled, SMA will no longer respond to SNMP queries with outdated data.
Enhancements

  • Added support for the following IO devices:
    • HPE Synergy 4820C 10/20/25Gb Converged Network Adapter
    • HPE StorFabric CN1200R-T Converged Network Adapter
    • HPE StorFabric CN1300R Converged Network Adapter
    • HPE Synergy 6410C 25/50Gb Ethernet Adapter
    • HPE Ethernet 100Gb 1-port 842QSFP28 Adapter
    • HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter
  • Added the following enhancements to Control Panel Applet:
    • Up to 8 trap destinations are supported in SNMP tab, along with user configuration and SNMPv3 settings
    • SNMP tab is now fully functional if iLO5 encryption is set to HighSecurity or FIPS mode
    • Button options are available to start, stop, enable or disable SMA service
    • GUI options are available to select time format and input the optional periodic test trap interval
    • Help content has expanded
  • SMA (System Management Assistant) service now supports all MIB OIDs and traps generated by iLO5 FW.
  • Added support for System Chassis Class of IML Events in Windows Event Log.
  • iSCSI MIB condition is now available in cpqHoMibHealthStatusArray.
  • AHS (Active Health System) NIC Link records now contain Interface Description string.

Version:1.20.0.0 (5 Feb 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


None

Enhancements

  • Added support for the following device:
    - HPE Smart Array P824i-p MR Adapter (cpqSasHbaModel: sasP824ip(14))
  • Added support for the following MIB OIDs:
    - cpqIdeAtaDiskMaximumOperatingTemp
    - cpqIdeAtaDiskDestructiveOperatingTemp
    - cpqSasLogDrvTable
  • Added support for a new Active Health System (AHS) record: "OS Logical Disk Usage"
  • Added UTF-8 support for Japanese characters to show correctly on iLO GUI
  • Enhanced AMS Control Panel Applet Help content
  • Added button options in AMS Control Panel Applet to start/stop AMS service, or enable/disable SMA service

Version:1.15.0.0(B) (15 Jan 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


none

Enhancements

Added support for Microsoft Windows 10 (64-bit) operating system.


Version:1.15.0.0 (25 Sep 2017)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • The overall network and controller status are no longer shown degraded on iLO GUI when an FC/FCoE port is not connected.
  • AMS no longer terminates intermittently after the service is started on systems with NVMe drives.
  • AMS no longer terminates on systems with Windows Server 2012 R2 and missing KB2919355.
Enhancements

  • AMS extends the default data polling interval from 30 seconds to 2 minutes, consequently CPU utilization increases less frequently.

Version:1.1.0.0 (12 Jul 2017)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Initial release of “Agentless Management Service for Windows X64”


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.