* RECOMMENDED * Systems ROMPaq Firmware Upgrade for HP ProLiant ML110 G4 Servers

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: BIOS (Entitlement Required) - System ROM
Version: 2007.07.20(A)(3 Aug 2007)
Operating System(s): DR-DOS
Microsoft Windows Server 2003
Microsoft Windows Server 2003 for 64-bit Extended Systems
Novell NetWare 6.5
Red Hat Enterprise Linux 3 (AMD64/EM64T)
Red Hat Enterprise Linux 3 (x86)
Red Hat Enterprise Linux 4 (AMD64/EM64T)
Red Hat Enterprise Linux 4 (x86)
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 9 (AMD64/EM64T)
SUSE Linux Enterprise Server 9 (x86)
File name: SP36639.exe (3.6 MB)
This release provides updated system ROM images for the latest maintenance releases of HP ProLiant ML110 G4 Servers.

Added an option to select USB devices in the boot order in the BIOS setup menu.

Added the string "Floppy" to USB storage devices that are under 5MB in size in the boot order in the BIOS setup menu.

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

742eb69743d62373a2f45ad88fe7acb17cf4982b2f52e1fba4a272505cdcef0e SP36639.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

This Enhanced SoftPaq contains utilities that can be used to restore and/or update the system ROM on the HP ProLiant Server.

1. Download the Enhanced SoftPaq to a directory on a system running Microsoft Windows 2000, Microsoft Windows Server 2003, or Microsoft Windows XP and change to that directory.

2. From that drive and directory, execute the downloaded Enhanced SoftPaq file simply by double clicking on the SPxxxxx file and follow the installation wizard to complete the Enhanced SoftPaq installation process. At the end of a successful installation of the Enhanced SoftPaq, a web page will automatically appear to provide you with the different methods for restoring and/or upgrading the firmware on the system.


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

This Enhanced SoftPaq version contains new functionality that provides additional firmware upgrade options to the user. Please review the user documentation contained within this Enhanced SoftPaq to learn more about these new features. All files contained within and created by this Enhanced SoftPaq are specific to this Proliant Server. Files are not interchangeable with other Proliant Server Families.


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Resolved an issue under Linux with using the "dd" command which could result in an unknown format or unable to update on certain USB DriveKeys.

Resolved an issue where the ESC key, ESC+0 and F10 will not work when using the keycodes.exe utility under DOS mode, or during POST, or in RBSU when using Console Redirection.

Resolved an issue where the CPU FAN runs at full speed when Xeon 3000-series processor is installed.

                        

This Enhanced SoftPaq version contains new functionality that provides additional firmware upgrade options to the user. Please review the user documentation contained within this Enhanced SoftPaq to learn more about these new features. All files contained within and created by this Enhanced SoftPaq are specific to this Proliant Server. Files are not interchangeable with other Proliant Server Families.

Version:2007.07.20(A) (3 Aug 2007)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Resolved an issue under Linux with using the "dd" command which could result in an unknown format or unable to update on certain USB DriveKeys.

Resolved an issue where the ESC key, ESC+0 and F10 will not work when using the keycodes.exe utility under DOS mode, or during POST, or in RBSU when using Console Redirection.

Resolved an issue where the CPU FAN runs at full speed when Xeon 3000-series processor is installed.

                        

Enhancements

Added an option to select USB devices in the boot order in the BIOS setup menu.

Added the string "Floppy" to USB storage devices that are under 5MB in size in the boot order in the BIOS setup menu.


Version:2007.04.14 (A) (8 May 2007)
Fixes
This System ROM upgrade integrates a new version of Intel support code for Dual-Core Intel Xeon 3000 Series processors. This Intel support code was provided to HP as a critical software update. This System ROM update has no known performance impact.

Resolved an issue with IPMI Device failed to enabled and prompt "Input/Output Range 0CA2 - 0CA3 not available."

Resolved an issue where it was required to press F1 to continue the boot process when there is a Smart Array harddisk failure during POST even though the F1 option in BIOS Setup Utility was set to delayed or disabled.

        


Version:2007.03.05 (A) (21 Mar 2007)
Fixes

Resolved an issue with the E200 Card Option ROM failing with the message "Expansion ROM initialization failed" while initializing with AHCI Enabled in the BIOS Setup Utility.

Resolved an issue with the Processor L1 cache size reported in the SMBIOS table with dual core processors.

Resolved an issue with 'F9' default boot sequence with HDD and USB key installed.

Updated the BMC System Event Log Full message from "Error 02A2: BMC System Error log (SEL) Full" to "BMC System Event log (SEL) Full".

Removed the warning beeps when the maximum number of Option ROMS is reached.

Enhancements

Added new Microcode support for the latest processor revisions.


Version:2006.09.25 (A) (16 Oct 2006)
Fixes

Resolved an issue where the LO100c option firmware date would display the previous firmware date after upgrading.

Removed the display of invalid Console Redirection options when the serial port is disabled.

Updated the POST display to indicate "MB System RAM Passed" instead of "M System RAM Passed".

Resolved an issue where the Xeon 3000 series processor is not displayed correctly in the BIOS Setup Utility. Resolved an issue with initializing the U320 PCI-E SCSI card during POST. The option ROM and configuration utility would not show up in POST.

Resolved an issue where the system Event Log in the BIOS Setup Utility was not in sync with the IPMI remote event log through web interface.

Resolved an issue where the removal of a fan or a fan failure would log a high critical event instead of a low critical event.

Resolved an issue where the AAR2610SA/64MB/HP RAID controller Option ROM and configuration utility does not show up in POST.

Resolved an issue with timeout failures when installing Windows through PXE.

Resolved an issue where HP OBDR USB tape (DAT 40) configuration is not available during POST.

Resolved an issue where LO100c Option "power policy" in the remote web interface did not function with change in synchronization with the BIOS Setup Utility thus it was not completely functional.

Corrected Com port display in the BIOS Setup Utilty from COM 1 and COM 2 to COM A and COM B respectively.

Resolved an issue where the BIOS Summary was not displaying correct Serial Port Address which is setup in the BIOS Setup Utility.

Resolved an issue where the HP logo screen is not displayed when using the HP USB tape device (DAT24, DAT40, and DAT72).

Resolved an issue where the system would not shutdown under Linux if a x1 or x4 PCI-E card is installed in the PCI-E x4 slot.

Resolved an issue which resulted in a hang or auto-reboot when using a USB tape drive and shutting down the system under Linux SUSE9 32bit with SP3.

Corrected the help description in the BIOS Setup Utility for the IPMI baud rate setup.

Resolved an issue where the system event log was not getting updated while being viewed.

Increased the volume of the system beeper for POST errors.

Resolved an issue where the F12 PXE boot option was not displayed when a POST error occurred.

Removed the "Shift + 1" function key from BIOS Setup Utility which was supposed to disable the selected boot devices in the Boot Menu but was not functional.

Resolved an issue where the fan speed readings between the BIOS Setup Utility and the LO100c web user interface were not synchronized.

Corrected the display in the BIOS Setup Utility "Boot" tab to display "CD-ROM / DVD-ROM" instead of "CD-ROM drive".

Modified the help message for the Enhanced Intel SpeedStep Technology to clearly differentiate the processor differences when using Linux SUSE 9.

Resolved an issue in the BIOS Setup Utility where the "share NIC mode" option could not be disabled after enabling and rebooting.
      

Enhancements

Added support for the latest Intel processor.

Made enhancements to reduce the fan noise.

Moved the enable/disable option for PXE to the Boot Menu in the BIOS Setup Utility.

Added the LO100c remote boot access function in the BIOS Setup Utility under IPMI "Set System Boot Options" to match the function under LO100c CLI functionality.


Version:2006.07.14 (16 Oct 2006)
Fixes
None.

Enhancements
Initial Release.


Type: BIOS (Entitlement Required) - System ROM
Version: 2007.07.20(A)(3 Aug 2007)
Operating System(s):
DR-DOS
Microsoft Windows Server 2003
Microsoft Windows Server 2003 for 64-bit Extended Systems
Novell NetWare 6.5
Red Hat Enterprise Linux 3 (AMD64/EM64T)
Red Hat Enterprise Linux 3 (x86)
Red Hat Enterprise Linux 4 (AMD64/EM64T)
Red Hat Enterprise Linux 4 (x86)
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 9 (AMD64/EM64T)
SUSE Linux Enterprise Server 9 (x86)

Description

This release provides updated system ROM images for the latest maintenance releases of HP ProLiant ML110 G4 Servers.

Enhancements

Added an option to select USB devices in the boot order in the BIOS setup menu.

Added the string "Floppy" to USB storage devices that are under 5MB in size in the boot order in the BIOS setup menu.

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

742eb69743d62373a2f45ad88fe7acb17cf4982b2f52e1fba4a272505cdcef0e SP36639.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

This Enhanced SoftPaq contains utilities that can be used to restore and/or update the system ROM on the HP ProLiant Server.

1. Download the Enhanced SoftPaq to a directory on a system running Microsoft Windows 2000, Microsoft Windows Server 2003, or Microsoft Windows XP and change to that directory.

2. From that drive and directory, execute the downloaded Enhanced SoftPaq file simply by double clicking on the SPxxxxx file and follow the installation wizard to complete the Enhanced SoftPaq installation process. At the end of a successful installation of the Enhanced SoftPaq, a web page will automatically appear to provide you with the different methods for restoring and/or upgrading the firmware on the system.


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

This Enhanced SoftPaq version contains new functionality that provides additional firmware upgrade options to the user. Please review the user documentation contained within this Enhanced SoftPaq to learn more about these new features. All files contained within and created by this Enhanced SoftPaq are specific to this Proliant Server. Files are not interchangeable with other Proliant Server Families.


Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Resolved an issue under Linux with using the "dd" command which could result in an unknown format or unable to update on certain USB DriveKeys.

Resolved an issue where the ESC key, ESC+0 and F10 will not work when using the keycodes.exe utility under DOS mode, or during POST, or in RBSU when using Console Redirection.

Resolved an issue where the CPU FAN runs at full speed when Xeon 3000-series processor is installed.

                        

Important

This Enhanced SoftPaq version contains new functionality that provides additional firmware upgrade options to the user. Please review the user documentation contained within this Enhanced SoftPaq to learn more about these new features. All files contained within and created by this Enhanced SoftPaq are specific to this Proliant Server. Files are not interchangeable with other Proliant Server Families.

Revision History

Version:2007.07.20(A) (3 Aug 2007)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Resolved an issue under Linux with using the "dd" command which could result in an unknown format or unable to update on certain USB DriveKeys.

Resolved an issue where the ESC key, ESC+0 and F10 will not work when using the keycodes.exe utility under DOS mode, or during POST, or in RBSU when using Console Redirection.

Resolved an issue where the CPU FAN runs at full speed when Xeon 3000-series processor is installed.

                        

Enhancements

Added an option to select USB devices in the boot order in the BIOS setup menu.

Added the string "Floppy" to USB storage devices that are under 5MB in size in the boot order in the BIOS setup menu.


Version:2007.04.14 (A) (8 May 2007)
Fixes
This System ROM upgrade integrates a new version of Intel support code for Dual-Core Intel Xeon 3000 Series processors. This Intel support code was provided to HP as a critical software update. This System ROM update has no known performance impact.

Resolved an issue with IPMI Device failed to enabled and prompt "Input/Output Range 0CA2 - 0CA3 not available."

Resolved an issue where it was required to press F1 to continue the boot process when there is a Smart Array harddisk failure during POST even though the F1 option in BIOS Setup Utility was set to delayed or disabled.

        


Version:2007.03.05 (A) (21 Mar 2007)
Fixes

Resolved an issue with the E200 Card Option ROM failing with the message "Expansion ROM initialization failed" while initializing with AHCI Enabled in the BIOS Setup Utility.

Resolved an issue with the Processor L1 cache size reported in the SMBIOS table with dual core processors.

Resolved an issue with 'F9' default boot sequence with HDD and USB key installed.

Updated the BMC System Event Log Full message from "Error 02A2: BMC System Error log (SEL) Full" to "BMC System Event log (SEL) Full".

Removed the warning beeps when the maximum number of Option ROMS is reached.

Enhancements

Added new Microcode support for the latest processor revisions.


Version:2006.09.25 (A) (16 Oct 2006)
Fixes

Resolved an issue where the LO100c option firmware date would display the previous firmware date after upgrading.

Removed the display of invalid Console Redirection options when the serial port is disabled.

Updated the POST display to indicate "MB System RAM Passed" instead of "M System RAM Passed".

Resolved an issue where the Xeon 3000 series processor is not displayed correctly in the BIOS Setup Utility. Resolved an issue with initializing the U320 PCI-E SCSI card during POST. The option ROM and configuration utility would not show up in POST.

Resolved an issue where the system Event Log in the BIOS Setup Utility was not in sync with the IPMI remote event log through web interface.

Resolved an issue where the removal of a fan or a fan failure would log a high critical event instead of a low critical event.

Resolved an issue where the AAR2610SA/64MB/HP RAID controller Option ROM and configuration utility does not show up in POST.

Resolved an issue with timeout failures when installing Windows through PXE.

Resolved an issue where HP OBDR USB tape (DAT 40) configuration is not available during POST.

Resolved an issue where LO100c Option "power policy" in the remote web interface did not function with change in synchronization with the BIOS Setup Utility thus it was not completely functional.

Corrected Com port display in the BIOS Setup Utilty from COM 1 and COM 2 to COM A and COM B respectively.

Resolved an issue where the BIOS Summary was not displaying correct Serial Port Address which is setup in the BIOS Setup Utility.

Resolved an issue where the HP logo screen is not displayed when using the HP USB tape device (DAT24, DAT40, and DAT72).

Resolved an issue where the system would not shutdown under Linux if a x1 or x4 PCI-E card is installed in the PCI-E x4 slot.

Resolved an issue which resulted in a hang or auto-reboot when using a USB tape drive and shutting down the system under Linux SUSE9 32bit with SP3.

Corrected the help description in the BIOS Setup Utility for the IPMI baud rate setup.

Resolved an issue where the system event log was not getting updated while being viewed.

Increased the volume of the system beeper for POST errors.

Resolved an issue where the F12 PXE boot option was not displayed when a POST error occurred.

Removed the "Shift + 1" function key from BIOS Setup Utility which was supposed to disable the selected boot devices in the Boot Menu but was not functional.

Resolved an issue where the fan speed readings between the BIOS Setup Utility and the LO100c web user interface were not synchronized.

Corrected the display in the BIOS Setup Utility "Boot" tab to display "CD-ROM / DVD-ROM" instead of "CD-ROM drive".

Modified the help message for the Enhanced Intel SpeedStep Technology to clearly differentiate the processor differences when using Linux SUSE 9.

Resolved an issue in the BIOS Setup Utility where the "share NIC mode" option could not be disabled after enabling and rebooting.
      

Enhancements

Added support for the latest Intel processor.

Made enhancements to reduce the fan noise.

Moved the enable/disable option for PXE to the Boot Menu in the BIOS Setup Utility.

Added the LO100c remote boot access function in the BIOS Setup Utility under IPMI "Set System Boot Options" to match the function under LO100c CLI functionality.


Version:2006.07.14 (16 Oct 2006)
Fixes
None.

Enhancements
Initial Release.


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.