Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Windows - HP StorageWorks P2000/MSA2000 146GB,300GB 10K SAS 6G SFF Hard Drive (DG0146FAMWL, DG0300FAMWN)

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPDD(21 Jul 2010)
Operating System(s): Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
File name: cp012560.exe (2.7 MB)
This Windows Smart Component contains a firmware update for the hard drive models DG0146FAMWL (146GB 10K SAS 6G) and DG0300FAMWN (300GB 10K SAS 6G) in HP StorageWorks P2000 G3 MSA and MSA2000 G2 configurations.

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

90ccc5445ec5ad07ed4a58f7d6383efb5884ef6823ab4100126bcea3fa36ca7b cp012560.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of array controller


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


Notes:

The Product Release Notes are located at https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p2040426092/v62913/579166-004_RN_DriveFW.htm

Failure Considerations:

  1. Single ported drive will not be flashed if the owner controller of that drive is not accessible through network.
  2. Drives will not be flashed if the drive is in a virtual disk which is being initialized, expanded, reconstructed, verified, or scrubbed.
  3. Flash operation on any pending disks will be aborted if the currently flashed drive is in LEFTOVR state or the virtual disk containing this disk is found to be in offline or critical state. If this does occur, the vdisk can be restored to online status by changing the drive status from leftover to available and then adding the drive to the vdisk as a spare. If a global spare drive was available, it will have been used to restore the vdisk to online status.

Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any P2000 G3 or MSA2000 array controller enclosure.


CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.

Version:HPDG (13 Oct 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue was fixed in this release of firmware:

  • HP ProLiant servers would power down due a hard drive over-temp condition that was falsely reported.

Version:HPDF (30 Mar 2012)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


  • This firmware corrects unsolicited drive resets that will cause the drive to abort any queued commands resulting in slower performance due to the host having to resubmit commands dropped and RESET events to be logged in the hardware error logs.
  • In a fail over environment, this firmware corrects a possible drive hang if the connection on the active ports is lost.

Version:HPDE (28 Mar 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.


Version:HPDD (21 Jul 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products


Type: Firmware - SAS Storage Disk
Version: HPDD(21 Jul 2010)
Operating System(s):
Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64

Description

This Windows Smart Component contains a firmware update for the hard drive models DG0146FAMWL (146GB 10K SAS 6G) and DG0300FAMWN (300GB 10K SAS 6G) in HP StorageWorks P2000 G3 MSA and MSA2000 G2 configurations.

Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products

Installation Instructions

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

90ccc5445ec5ad07ed4a58f7d6383efb5884ef6823ab4100126bcea3fa36ca7b cp012560.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of array controller


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


Notes:

The Product Release Notes are located at https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p2040426092/v62913/579166-004_RN_DriveFW.htm

Failure Considerations:

  1. Single ported drive will not be flashed if the owner controller of that drive is not accessible through network.
  2. Drives will not be flashed if the drive is in a virtual disk which is being initialized, expanded, reconstructed, verified, or scrubbed.
  3. Flash operation on any pending disks will be aborted if the currently flashed drive is in LEFTOVR state or the virtual disk containing this disk is found to be in offline or critical state. If this does occur, the vdisk can be restored to online status by changing the drive status from leftover to available and then adding the drive to the vdisk as a spare. If a global spare drive was available, it will have been used to restore the vdisk to online status.

Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any P2000 G3 or MSA2000 array controller enclosure.


Important

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.

Revision History

Version:HPDG (13 Oct 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue was fixed in this release of firmware:

  • HP ProLiant servers would power down due a hard drive over-temp condition that was falsely reported.

Version:HPDF (30 Mar 2012)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


  • This firmware corrects unsolicited drive resets that will cause the drive to abort any queued commands resulting in slower performance due to the host having to resubmit commands dropped and RESET events to be logged in the hardware error logs.
  • In a fail over environment, this firmware corrects a possible drive hang if the connection on the active ports is lost.

Version:HPDE (28 Mar 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.


Version:HPDD (21 Jul 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products