Type: Firmware - SAS Storage Disk
Version: 0009 (A)(6 Nov 2014)
Operating System(s): Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
File name: cp025175.exe (2.5 MB)
This Windows Smart Component contains a firmware update for LFF hard drive models ST3146356SS (146GB 15K SAS 6G), ST3300656SS (300GB 15K SAS 6G) and ST3450856SS (450GB 15K SAS 6G) in HP P2000 G3 and MSA2000 G2 Storage Arrays.

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP P2000 G3 and MSA2000 G2 Storage Arrays.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

22996f0def525ce987fcefe644ccd238 cp025175.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.
  2. Using Windows Explorer, navigate to the directory containing the download.
  3. Double click the executable file.
  4. Follow onscreen instructions.

CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of that username


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0009(A) is not necessary if HDDs are currently running 0009 firmware.
Only the Smart Component package digital certificate has been updated for version 0009(A).


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP P2000 G3 and MSA2000 G2 Storage Arrays.


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP P2000 G3 10GbE iSCSI MSA Dual Controller LFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller LFF Array System
  • HP P2000 G3 SAS MSA Dual Controller LFF Array System
  • HP P2000 G3 MSA FC Dual Controller LFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller LFF Array
  • HP MSA2000 Single I/O 3.5 inch 12 Drive Enclosure
  • HP MSA2000 Dual I/O 3.5 inch 12 Drive Enclosure
  • HP P2000 Dual I/O LFF Drive Enclosure
  • Modular Smart Array 2312sa
  • Modular Smart Array 2312fc
  • Modular Smart Array 2312i

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0009(A) is not necessary if HDDs are currently running 0009 firmware.
Only the Smart Component package digital certificate has been updated for version 0009(A).


Following fixes were added in 0009:

  • Fixed an issue clearing write cache
  • Fixed a timeout issue during re-write operations
  • Fixed a timing issue with seeks

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP P2000 G3 and MSA2000 G2 Storage Arrays.

Version:0009 (A) (6 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0009(A) is not necessary if HDDs are currently running 0009 firmware.
Only the Smart Component package digital certificate has been updated for version 0009(A).


Following fixes were added in 0009:

  • Fixed an issue clearing write cache
  • Fixed a timeout issue during re-write operations
  • Fixed a timing issue with seeks

Version:0009 (4 Oct 2011)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Fixed an issue clearing write cache
  • Fixed a timeout issue during re-write operations
  • Fixed a timing issue with seeks

Version:0007 (26 Aug 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Use this firmware to flash LFF 15K SAS hard drive model ST3146356SS(146GB) in P2000 G3 MSA and MSA2000 configurations ONLY. Do not use this firmware to flash the drives if the drives are in any other configurations.


Initial release of firmware for LFF 15K SAS hard drive model ST3146356SS(146GB) in P2000 G3 MSA and MSA2000 configurations ONLY.


Type: Firmware - SAS Storage Disk
Version: 0009 (A)(6 Nov 2014)
Operating System(s):
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2

Description

This Windows Smart Component contains a firmware update for LFF hard drive models ST3146356SS (146GB 15K SAS 6G), ST3300656SS (300GB 15K SAS 6G) and ST3450856SS (450GB 15K SAS 6G) in HP P2000 G3 and MSA2000 G2 Storage Arrays.

Installation Instructions

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP P2000 G3 and MSA2000 G2 Storage Arrays.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

22996f0def525ce987fcefe644ccd238 cp025175.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.
  2. Using Windows Explorer, navigate to the directory containing the download.
  3. Double click the executable file.
  4. Follow onscreen instructions.

CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of that username


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0009(A) is not necessary if HDDs are currently running 0009 firmware.
Only the Smart Component package digital certificate has been updated for version 0009(A).


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP P2000 G3 and MSA2000 G2 Storage Arrays.


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP P2000 G3 10GbE iSCSI MSA Dual Controller LFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller LFF Array System
  • HP P2000 G3 SAS MSA Dual Controller LFF Array System
  • HP P2000 G3 MSA FC Dual Controller LFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller LFF Array
  • HP MSA2000 Single I/O 3.5 inch 12 Drive Enclosure
  • HP MSA2000 Dual I/O 3.5 inch 12 Drive Enclosure
  • HP P2000 Dual I/O LFF Drive Enclosure
  • Modular Smart Array 2312sa
  • Modular Smart Array 2312fc
  • Modular Smart Array 2312i

Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0009(A) is not necessary if HDDs are currently running 0009 firmware.
Only the Smart Component package digital certificate has been updated for version 0009(A).


Following fixes were added in 0009:

  • Fixed an issue clearing write cache
  • Fixed a timeout issue during re-write operations
  • Fixed a timing issue with seeks

Important

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP P2000 G3 and MSA2000 G2 Storage Arrays.

Revision History

Version:0009 (A) (6 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0009(A) is not necessary if HDDs are currently running 0009 firmware.
Only the Smart Component package digital certificate has been updated for version 0009(A).


Following fixes were added in 0009:

  • Fixed an issue clearing write cache
  • Fixed a timeout issue during re-write operations
  • Fixed a timing issue with seeks

Version:0009 (4 Oct 2011)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Fixed an issue clearing write cache
  • Fixed a timeout issue during re-write operations
  • Fixed a timing issue with seeks

Version:0007 (26 Aug 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Use this firmware to flash LFF 15K SAS hard drive model ST3146356SS(146GB) in P2000 G3 MSA and MSA2000 configurations ONLY. Do not use this firmware to flash the drives if the drives are in any other configurations.


Initial release of firmware for LFF 15K SAS hard drive model ST3146356SS(146GB) in P2000 G3 MSA and MSA2000 configurations ONLY.


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.