Printable version

Drivers & software

Online ROM Flash Component for Windows (x64) - HP 12Gb/s SAS Expander Firmware for HP Smart Array Controllers and HP HBA Controllers

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - Storage Controller
Version: 2.07(1 Oct 2015)
Operating System(s): Microsoft Windows Server 2008 R2
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
Multi-part download
File name: cp027582.md5 (48 Bytes)
File name: cp027582.exe (4.1 MB)
This Smart Component provides firmware for the HP 12Gb/s SAS Expander

To ensure the integrity of your download, HP recommends verifying your results with the following MD5 Checksum values:

f6c900ceab2a7f7bd7fd976fe084c4c5 cp027582.exe
9c10a2de04ddb8f06de8ad889f5a24fa cp027582.md5

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Power cycle/ cold reboot is required if firmware is upgraded from version 1.31 or earlier.

To update firmware from Windows operating system on target server:

  • Place the Smart Component in a temporary directory.
  • Double-click on the Smart Component.
  • Follow the directions given by the Smart Component.
  • Reboot your system if you would like the update to take effect immediately.

To use HP Smart Update Manager from the HP Service Pack for ProLiant :

 

  • Place the desired firmware to be updated in the directory, \SPP20xxxxx\hp\swpackages
  • Locate Start.html which is found in the root of the ISO
  • Open the html file in a supported browser
  • Follow the instructions on the screen

 


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Notes:

Deliverable Name:
     Online ROM Flash Component for Windows – HP 12Gb/s SAS Expander Firmware for HP Smart Array Controllers and HP HBA Controllers

Release Version and/or Date:
     2.07

Last Recommended or Critical Version:
     1.80

Previous Version of Firmware:
     1.80

Firmware Dependency:
     None

Enhancements/New Features:

     None

Problems Fixed:

  • While performing a firmware upgrade on an HP 12Gb/s SAS Expander card, an issue infrequently occurred that caused the card to become unusable. HP 12Gb/s SAS Expander firmware version 2.07 resolved this issue.

Known Issues:
     None


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • While performing a firmware upgrade on an HP 12Gb/s SAS Expander card, an issue infrequently occurred that caused the card to become unusable. HP 12Gb/s SAS Expander firmware version 2.07 resolved this issue.

Version:4.21(B) (27 Nov 2018)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Note: If version 4.21 was previously installed, then it is not necessary to upgrade to version 4.21 (B).


  • Added support for Microsoft Windows Server 2019 OS

Version:4.22 (9 Sep 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Fixes an issue where false Smart Carrier authenication errors may happen.

Version:4.21 (20 Sep 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


The following issues are resolved in version 4.21:

  • Expander may reset during heavy SSACLI polling
  • SATA drives may take longer to spin up, not be initially detected, and then hot add later. This can prevent system boot or affect the logical drive status.

Version:4.02(B) (26 Jun 2018)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

  • Customers who already have firmware version 4.02 installed do not need to update to 4.02 (B).

Added HPE Digital Signature


Version:4.02 (5 Feb 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Changed the Enclosure's Target and LUN address to the appropriate unique values. Previously these addresses would conflict with the SATA drive in bay #1 which interfered with software defined storage solutions such as Storage Spaces Direct.

Version:3.17 (25 Sep 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • SATA hard disk drives connected to the HPE 12Gb/s SAS Expander card may not be detected when cold booting a HPE ProLiant server with a HPE Smart Array SR Gen10 controller

Version:3.14 (12 Jul 2017)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Added support for ML350, DL380, and DL560 Gen10 servers.

Version:2.10 (24 Oct 2016)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Rebranded the controller information from HP 12G SAS Expander card to HPE 12G SAS Expander card.
  • Added support for the Microsoft® Windows Server® 2016 OS.

Version:2.09 (1 Apr 2016)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • The HPE 12Gb/s SAS Expander firmware version 2.09 resolves an issue where an incorrect SAS address was returned by the Device Identification Inquiry for Vital Product Data page. As a result, applications using this information may report incorrect data about the storage system topology.   


Version:2.07 (1 Oct 2015)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • While performing a firmware upgrade on an HP 12Gb/s SAS Expander card, an issue infrequently occurred that caused the card to become unusable. HP 12Gb/s SAS Expander firmware version 2.07 resolved this issue.


Version:1.8 (15 Jun 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

  • Power cycle/ cold reboot is required if firmware is upgraded from version 1.31 or earlier.


  • A rare race condition in a system with SAS and SATA drives, where SATA drives were not discovered during server power-on.
Enhancements

  • Added support to reset the expander after firmware flash.

Version:1.31 (30 Mar 2015)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Problems Fixed:

  • On rare occasions, incorrect data may be read or written while a controller is rebuilding a drive.
  • Disabled Edge-Buffering to address a rare data integrity issue seen with a drive that had bad blocks.
  • In rare instances, on an HP ProLiant Gen9 series server, the Smart Array controller would detect an HP Hard Disk Drive (HDD) as a non-HP drive. For additional information please refer to the customer advisory # c04597377
Enhancements

Enhancements/New Features:

  • Firmware now reads the max link rate from the backplane NVRAM and sets the rate accordingly. The expander firmware will adjust the SAS links to the appropriate speed based on the backplane type. The firmware will not try to force slower backplanes to higher link rates.

Version:1.01 (9 Sep 2014)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Enhancements/New Features:

  • Initial Release

Type: Firmware - Storage Controller
Version: 2.07(1 Oct 2015)
Operating System(s):
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2

Description

This Smart Component provides firmware for the HP 12Gb/s SAS Expander

Installation Instructions

To ensure the integrity of your download, HP recommends verifying your results with the following MD5 Checksum values:

f6c900ceab2a7f7bd7fd976fe084c4c5 cp027582.exe
9c10a2de04ddb8f06de8ad889f5a24fa cp027582.md5

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Power cycle/ cold reboot is required if firmware is upgraded from version 1.31 or earlier.

To update firmware from Windows operating system on target server:

  • Place the Smart Component in a temporary directory.
  • Double-click on the Smart Component.
  • Follow the directions given by the Smart Component.
  • Reboot your system if you would like the update to take effect immediately.

To use HP Smart Update Manager from the HP Service Pack for ProLiant :

 

  • Place the desired firmware to be updated in the directory, \SPP20xxxxx\hp\swpackages
  • Locate Start.html which is found in the root of the ISO
  • Open the html file in a supported browser
  • Follow the instructions on the screen

 


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Notes:

Deliverable Name:
     Online ROM Flash Component for Windows – HP 12Gb/s SAS Expander Firmware for HP Smart Array Controllers and HP HBA Controllers

Release Version and/or Date:
     2.07

Last Recommended or Critical Version:
     1.80

Previous Version of Firmware:
     1.80

Firmware Dependency:
     None

Enhancements/New Features:

     None

Problems Fixed:

  • While performing a firmware upgrade on an HP 12Gb/s SAS Expander card, an issue infrequently occurred that caused the card to become unusable. HP 12Gb/s SAS Expander firmware version 2.07 resolved this issue.

Known Issues:
     None


Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • While performing a firmware upgrade on an HP 12Gb/s SAS Expander card, an issue infrequently occurred that caused the card to become unusable. HP 12Gb/s SAS Expander firmware version 2.07 resolved this issue.

Revision History

Version:4.21(B) (27 Nov 2018)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Note: If version 4.21 was previously installed, then it is not necessary to upgrade to version 4.21 (B).


  • Added support for Microsoft Windows Server 2019 OS

Version:4.22 (9 Sep 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • Fixes an issue where false Smart Carrier authenication errors may happen.

Version:4.21 (20 Sep 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


The following issues are resolved in version 4.21:

  • Expander may reset during heavy SSACLI polling
  • SATA drives may take longer to spin up, not be initially detected, and then hot add later. This can prevent system boot or affect the logical drive status.

Version:4.02(B) (26 Jun 2018)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

  • Customers who already have firmware version 4.02 installed do not need to update to 4.02 (B).

Added HPE Digital Signature


Version:4.02 (5 Feb 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Changed the Enclosure's Target and LUN address to the appropriate unique values. Previously these addresses would conflict with the SATA drive in bay #1 which interfered with software defined storage solutions such as Storage Spaces Direct.

Version:3.17 (25 Sep 2017)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • SATA hard disk drives connected to the HPE 12Gb/s SAS Expander card may not be detected when cold booting a HPE ProLiant server with a HPE Smart Array SR Gen10 controller

Version:3.14 (12 Jul 2017)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Added support for ML350, DL380, and DL560 Gen10 servers.

Version:2.10 (24 Oct 2016)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • Rebranded the controller information from HP 12G SAS Expander card to HPE 12G SAS Expander card.
  • Added support for the Microsoft® Windows Server® 2016 OS.

Version:2.09 (1 Apr 2016)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • The HPE 12Gb/s SAS Expander firmware version 2.09 resolves an issue where an incorrect SAS address was returned by the Device Identification Inquiry for Vital Product Data page. As a result, applications using this information may report incorrect data about the storage system topology.   


Version:2.07 (1 Oct 2015)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • While performing a firmware upgrade on an HP 12Gb/s SAS Expander card, an issue infrequently occurred that caused the card to become unusable. HP 12Gb/s SAS Expander firmware version 2.07 resolved this issue.


Version:1.8 (15 Jun 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

  • Power cycle/ cold reboot is required if firmware is upgraded from version 1.31 or earlier.


  • A rare race condition in a system with SAS and SATA drives, where SATA drives were not discovered during server power-on.
Enhancements

  • Added support to reset the expander after firmware flash.

Version:1.31 (30 Mar 2015)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Problems Fixed:

  • On rare occasions, incorrect data may be read or written while a controller is rebuilding a drive.
  • Disabled Edge-Buffering to address a rare data integrity issue seen with a drive that had bad blocks.
  • In rare instances, on an HP ProLiant Gen9 series server, the Smart Array controller would detect an HP Hard Disk Drive (HDD) as a non-HP drive. For additional information please refer to the customer advisory # c04597377
Enhancements

Enhancements/New Features:

  • Firmware now reads the max link rate from the backplane NVRAM and sets the rate accordingly. The expander firmware will adjust the SAS links to the appropriate speed based on the backplane type. The firmware will not try to force slower backplanes to higher link rates.

Version:1.01 (9 Sep 2014)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Enhancements/New Features:

  • Initial Release

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.