Printable version

Drivers & software

HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - Network
Version: 2.20.4(25 Sep 2017)
Operating System(s): Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 12
Multi-part download
File name: firmware-nic-qlogic-nx2-2.20.4-1.1.x86_64.compsig (2.5 KB)
File name: firmware-nic-qlogic-nx2-2.20.4-1.1.x86_64.rpm (2.8 MB)
This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform.

This product now supports Red Hat Enterprise Linux 7 Update 4.
This product now supports SUSE Linux Enterprise Server 12 SP3.

Prerequisites:

This package requires the appropriate driver for your network adapter be installed and all Ethernet ports brought up (ifup ethX or ifconfig ethX up) before firmware can be updated.


To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

094c43863c83194ad1a3a9d5b581f456127d8f8bd7d9b1bb034402434929191f firmware-nic-qlogic-nx2-2.20.4-1.1.x86_64.rpm
47c89c43fb5a7286e1b9232d8dfabb4c9ef6e76a0eece7ca88c065f8eccabbda firmware-nic-qlogic-nx2-2.20.4-1.1.x86_64.compsig

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Updating adapter firmware with rpm installed:

  • Install this NIC firmware rpm with the following command: rpm -ivh <rpm_filename>.rpm. 

This command will extract the contents to "/usr/lib/x86_64-linux-gnu."
The CP032532.scexe script is located in the "hp-scexe-compat'' folder. Further information is available in CP032532.txt file in the "hp-firmware-nic-*" folder. The actual name of the "hp-firmware-nic-*" folder is based on the version of the rpm to be installed.  

  • To install the firmware, execute ONE of the following commands:
    • ./CP032532.scexe in the "/usr/lib/x86_64-linux-gnu/hp-scexe-compat" location.
    • ./hpsetup in the "hp-firmware-nic-*" location.   

  • To uninstall this rpm, execute the folllowing command: rpm -e <rpm_package_name>

 

Updating adapter firmware without installing the rpm:

  • Extract the contents of the rpm with the following command: rpm2cpio <rpm_filename>.rpm | cpio -id

This will extract the contents of the rpm to the "usr" folder in the current directory.

  • Navigate to the "usr/lib/x86_64-linux-gnu/hp-firmware-nic-*" location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-nic-*' folder is based on the version of the rpm.

 

Additional Information:

  • The results of the firmware upgrade are saved in CP032532.log at "/var/cpq/."
  • The device ID in NPAR (NIC Partitioning) mode is different from the device ID used for Flex10, or (forced) Single Function mode.  For example, adapter device IDs '0x168E' and '0x16A2' become '0x16AE' and '0x16A4,' respectively, after enabling NPAR.
  • Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.
  • Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.

 


End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Important:

HPE recommends HPE QLogic NX2 10/20GbE Multifunction Drivers for Linux, versions 7.14.29-2 or later, for use with the firmware in this package.


Notes:

This software package contains combo image v7.15.64 with the following firmware versions:

NIC Boot Code Version PXE Version UEFI Version iSCSI Version FCoE Version CCM Version L2 Version
HP Flex-10 10Gb 2-port 530FLB Adapter
HP Ethernet 10Gb 2-port 530SFP+ Adapter
HP Ethernet 10Gb 2-port 530T Adapter
7.14.62 7.14.10 8.0.0 n/a n/a 7.14.4 7.12.25

HP Ethernet 10Gb 2-port 533FLR-T Adapter
HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter
HP FlexFabric 10Gb 2-port 534M Adapter
HP FlexFabric 10Gb 2-port 536FLB Adapter
HPE FlexFabric 10Gb 4-port 536FLR-T Adapter
HP FlexFabric 20Gb 2-port 630FLB Adapter
HP FlexFabric 20Gb 2-port 630M Adapter
HP StoreFabric CN1100R Dual Port Converged Network Adapter
HPE StoreFabric CN1100R-T Converged Network Adapter
HPE Synergy 3820C 10/20Gb Converged Network Adapter
HPE Synergy 10Gb 2-port 2820C Converged Network Adapter

7.14.62 7.14.10 8.0.0 7.14.0 7.14.3 7.14.4 7.12.25

 


Supported Devices and Features:

This driver supports the following network adapters:

  • HP Flex-10 10Gb 2-port 530FLB Adapter
  • HP Ethernet 10Gb 2-port 530SFP+ Adapter
  • HP Ethernet 10Gb 2-port 530T Adapter
  • HP NC532m Dual Port 10GbE Multifunction BL-c Adapter
  • HP Ethernet 10Gb 2-port 533FLR-T Adapter
  • HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter
  • HP FlexFabric 10Gb 2-port 534M Adapter
  • HP FlexFabric 10Gb 2-port 536FLB Adapter
  • HPE FlexFabric 10Gb 4-port 536FLR-T Adapter  
  • HP FlexFabric 20Gb 2-port 630FLB Adapter
  • HP FlexFabric 20Gb 2-port 630M Adapter
  • HP StoreFabric CN1100R Dual Port Converged Network Adapter
  • HPE StoreFabric CN1100R-T Converged Network Adapter
  • HPE Synergy 10Gb 2820C Ethernet Adapter
  • HPE Synergy 3820C 10/20Gb Converged Network Adapter

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where a network adapter cannot be re-added to a NIC bond after being removed from the bond.

This product addresses an issue where adapters are not reporting the correct temperature in the Integrated Lights Out (iLO) webpage.

This product addresses an issue where the value set for Maximum Transmission Unit (MTU) setting wasn't preserved and instead gets reverted back to default value on system reboot.

HPE recommends HPE QLogic NX2 10/20GbE Multifunction Drivers for Linux, versions 7.14.29-2 or later, for use with the firmware in this package.

Version:2.23.0 (27 Nov 2018)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product now supports Red Hat Enterprise Linux 6 Update 10.


Version:2.22.56 (27 Sep 2018)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product now supports SUSE Linux Enterprise Server 15.


Version:2.22.15 (26 Jun 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product corrects an issue where users may see an error message when they attempt to restore the adapter's configuration settings to defaults by pressing F7 under the ‘System Utilities->System Configuration’ menu.


Version:2.21.15 (5 Feb 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • This product corrects an issue where the Maximum Transmission Unit (MTU) setting value reverts to the default value after a system reboot.
  • This product corrects an issue where an adapter’s configuration menu doesn't correctly prompt for reboot after changes are made that require a reboot.
  • This product corrects a high latency issue seen during high ping activity.
  • This product corrects an issue where OneView displays the error message "Server profile settings conflict with the server hardware configuration" when applying the server profile to a server running VMware ESXi 6.x.
  • This product corrects an issue where the iSCSI settings configured in the OneView Profile are not correctly applied to the adapter.
  • This product corrects an issue where an error message is seen when entering the ‘MBA Configuration Menu’ under the adapter’s settings (under the ‘System Utilities->System Configuration’ menu) and attempting to restore the defaults. 
  • This product corrects an issue where the iSCSI multipath does not work correctly in ‘Legacy BIOS Mode’.
  • This product corrects an issue where the virtual World Wide Port Name(WWPN)/World Wide Node Name(WWNN) are not programmed properly when applying the OneView Server Profile.
  • This product addresses an issue where the user sees the error message "Unable to find a FibreChannel boot source for server" in OneView when applying the Server Profile with Fibre Channel network paths configured.
Enhancements

  • The default 'Boot Retry Count' has been increased from 'No Retry' to '6.'
  • Configuration settings are now localized.

Version:2.20.4 (25 Sep 2017)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where a network adapter cannot be re-added to a NIC bond after being removed from the bond.

This product addresses an issue where adapters are not reporting the correct temperature in the Integrated Lights Out (iLO) webpage.

This product addresses an issue where the value set for Maximum Transmission Unit (MTU) setting wasn't preserved and instead gets reverted back to default value on system reboot.

Enhancements

This product now supports Red Hat Enterprise Linux 7 Update 4.
This product now supports SUSE Linux Enterprise Server 12 SP3.


Version:2.19.22 (12 Jul 2017)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where the system boots to an FCoE target when the FCoE ports are marked as “Not Bootable” in the OneView profile.

This product addresses an issue booting to an iSCSI target fails when the target is configured with a sixteen character long mutual Challenge Handshake Authentication Protocol (CHAP) secret.

This product addresses an issue where a network adapter’s configuration settings are not reset to defaults when the adapter is moved to a different slot and the system is booted in ‘Legacy BIOS Mode’.

This product addresses an issue where the system’s power-on self-test (POST) duration is extended when a single interconnect module (ICM) is installed in the enclosure and used to configure the logical interconnect group (LIG).

This product addresses an issue where the configuration settings of the HPE Synergy 3820C 10/20Gb Converged Network Adapter revert to the default values after a system restart.

This product addresses an issue where booting to an iSCSI target fails intermittently across multiple platform reboots.

This product addresses an issue where OneView displays the downlink port state as “Linked” for a network adapter that is disabled in the OS.

This product addresses an issue where a firmware update fails with a "segfault" error.


Version:2.18.44 (24 Oct 2016)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where the iSCSI and FCoE configuration menus are displayed after NPAR is enabled.

This product addresses an issue where expected network devices don't appear in the Legacy BIOS Boot Order menu.

Enhancements

This product now supports the following network adapters:

  • HPE Synergy 3820C 10/20Gb Converged Network Adapter
  • HPE Synergy 10Gb 2-port 2820C Converged Network Adapter

Version:2.18.1 (26 Sep 2016)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where the iSCSI and FCoE configuration menus are displayed after NPAR is enabled.

This product addresses an issue where expected network devices don't appear in the Legacy BIOS Boot Order menu.

Enhancements

This product now supports the HPE FlexFabric 10Gb 4-port 536FLR-T Adapter.


Version:2.17.16 (1 Apr 2016)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product corrects an issue where Boot from SAN in Legacy mode fails (hang observed during OS boot) because the FCoE ROM doesn't correctly honor the link status set by the Virtual Connect Manager.

This product corrects an issue where UEFI FCoE boot path sends incorrect notification to Management Firmware (MFW) about a virtual function link change, which eventually results in a deadlock with virtual link down.

This product corrects an issue where the fallback Boot from SAN fails even though each port is mapped to a different Virtual Connect Bay and only one of the bays is powered off.

This product corrects an issue where the Smartlink function does not work properly in FCoE SAN boot environment when server 'Boot Mode' is 'Legacy BIOS Mode.'

This product corrects an issue where the FCoE UEFI driver is unable to find LUNs when multiple FCoE VLANs are enabled.

Enhancements

This product now supports the HPE StoreFabric CN1100R-T Converged Network Adapter.

This product now provides the capability of converting an 'HP FlexFabric 10Gb 2-port 533FLR-T Adapter' into a Converged Network Adapter.


Version:2.16.20 (1 Oct 2015)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product now supports Red Hat Enterprise Linux 6 Update 7.

This product now supports SUSE LINUX Enterprise Server 11 SP4.


Version:2.15.19 (15 Jun 2015)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This firmware provides a new option in the NIC ROM-Based Setup Utility (RBSU) menu (HP’s UEFI System Utilities – F9 at POST) to allow enabling and disabling of HP shared memory features.


Type: Firmware - Network
Version: 2.20.4(25 Sep 2017)
Operating System(s):
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 12

Description

This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform.

Enhancements

This product now supports Red Hat Enterprise Linux 7 Update 4.
This product now supports SUSE Linux Enterprise Server 12 SP3.

Installation Instructions

Prerequisites:

This package requires the appropriate driver for your network adapter be installed and all Ethernet ports brought up (ifup ethX or ifconfig ethX up) before firmware can be updated.


To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

094c43863c83194ad1a3a9d5b581f456127d8f8bd7d9b1bb034402434929191f firmware-nic-qlogic-nx2-2.20.4-1.1.x86_64.rpm
47c89c43fb5a7286e1b9232d8dfabb4c9ef6e76a0eece7ca88c065f8eccabbda firmware-nic-qlogic-nx2-2.20.4-1.1.x86_64.compsig

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Updating adapter firmware with rpm installed:

  • Install this NIC firmware rpm with the following command: rpm -ivh <rpm_filename>.rpm. 

This command will extract the contents to "/usr/lib/x86_64-linux-gnu."
The CP032532.scexe script is located in the "hp-scexe-compat'' folder. Further information is available in CP032532.txt file in the "hp-firmware-nic-*" folder. The actual name of the "hp-firmware-nic-*" folder is based on the version of the rpm to be installed.  

  • To install the firmware, execute ONE of the following commands:
    • ./CP032532.scexe in the "/usr/lib/x86_64-linux-gnu/hp-scexe-compat" location.
    • ./hpsetup in the "hp-firmware-nic-*" location.   

  • To uninstall this rpm, execute the folllowing command: rpm -e <rpm_package_name>

 

Updating adapter firmware without installing the rpm:

  • Extract the contents of the rpm with the following command: rpm2cpio <rpm_filename>.rpm | cpio -id

This will extract the contents of the rpm to the "usr" folder in the current directory.

  • Navigate to the "usr/lib/x86_64-linux-gnu/hp-firmware-nic-*" location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-nic-*' folder is based on the version of the rpm.

 

Additional Information:

  • The results of the firmware upgrade are saved in CP032532.log at "/var/cpq/."
  • The device ID in NPAR (NIC Partitioning) mode is different from the device ID used for Flex10, or (forced) Single Function mode.  For example, adapter device IDs '0x168E' and '0x16A2' become '0x16AE' and '0x16A4,' respectively, after enabling NPAR.
  • Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.
  • Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.

 


Release Notes

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Important:

HPE recommends HPE QLogic NX2 10/20GbE Multifunction Drivers for Linux, versions 7.14.29-2 or later, for use with the firmware in this package.


Notes:

This software package contains combo image v7.15.64 with the following firmware versions:

NIC Boot Code Version PXE Version UEFI Version iSCSI Version FCoE Version CCM Version L2 Version
HP Flex-10 10Gb 2-port 530FLB Adapter
HP Ethernet 10Gb 2-port 530SFP+ Adapter
HP Ethernet 10Gb 2-port 530T Adapter
7.14.62 7.14.10 8.0.0 n/a n/a 7.14.4 7.12.25

HP Ethernet 10Gb 2-port 533FLR-T Adapter
HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter
HP FlexFabric 10Gb 2-port 534M Adapter
HP FlexFabric 10Gb 2-port 536FLB Adapter
HPE FlexFabric 10Gb 4-port 536FLR-T Adapter
HP FlexFabric 20Gb 2-port 630FLB Adapter
HP FlexFabric 20Gb 2-port 630M Adapter
HP StoreFabric CN1100R Dual Port Converged Network Adapter
HPE StoreFabric CN1100R-T Converged Network Adapter
HPE Synergy 3820C 10/20Gb Converged Network Adapter
HPE Synergy 10Gb 2-port 2820C Converged Network Adapter

7.14.62 7.14.10 8.0.0 7.14.0 7.14.3 7.14.4 7.12.25

 


Supported Devices and Features:

This driver supports the following network adapters:

  • HP Flex-10 10Gb 2-port 530FLB Adapter
  • HP Ethernet 10Gb 2-port 530SFP+ Adapter
  • HP Ethernet 10Gb 2-port 530T Adapter
  • HP NC532m Dual Port 10GbE Multifunction BL-c Adapter
  • HP Ethernet 10Gb 2-port 533FLR-T Adapter
  • HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter
  • HP FlexFabric 10Gb 2-port 534M Adapter
  • HP FlexFabric 10Gb 2-port 536FLB Adapter
  • HPE FlexFabric 10Gb 4-port 536FLR-T Adapter  
  • HP FlexFabric 20Gb 2-port 630FLB Adapter
  • HP FlexFabric 20Gb 2-port 630M Adapter
  • HP StoreFabric CN1100R Dual Port Converged Network Adapter
  • HPE StoreFabric CN1100R-T Converged Network Adapter
  • HPE Synergy 10Gb 2820C Ethernet Adapter
  • HPE Synergy 3820C 10/20Gb Converged Network Adapter

Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where a network adapter cannot be re-added to a NIC bond after being removed from the bond.

This product addresses an issue where adapters are not reporting the correct temperature in the Integrated Lights Out (iLO) webpage.

This product addresses an issue where the value set for Maximum Transmission Unit (MTU) setting wasn't preserved and instead gets reverted back to default value on system reboot.

Important

HPE recommends HPE QLogic NX2 10/20GbE Multifunction Drivers for Linux, versions 7.14.29-2 or later, for use with the firmware in this package.

Revision History

Version:2.23.0 (27 Nov 2018)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product now supports Red Hat Enterprise Linux 6 Update 10.


Version:2.22.56 (27 Sep 2018)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product now supports SUSE Linux Enterprise Server 15.


Version:2.22.15 (26 Jun 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product corrects an issue where users may see an error message when they attempt to restore the adapter's configuration settings to defaults by pressing F7 under the ‘System Utilities->System Configuration’ menu.


Version:2.21.15 (5 Feb 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


  • This product corrects an issue where the Maximum Transmission Unit (MTU) setting value reverts to the default value after a system reboot.
  • This product corrects an issue where an adapter’s configuration menu doesn't correctly prompt for reboot after changes are made that require a reboot.
  • This product corrects a high latency issue seen during high ping activity.
  • This product corrects an issue where OneView displays the error message "Server profile settings conflict with the server hardware configuration" when applying the server profile to a server running VMware ESXi 6.x.
  • This product corrects an issue where the iSCSI settings configured in the OneView Profile are not correctly applied to the adapter.
  • This product corrects an issue where an error message is seen when entering the ‘MBA Configuration Menu’ under the adapter’s settings (under the ‘System Utilities->System Configuration’ menu) and attempting to restore the defaults. 
  • This product corrects an issue where the iSCSI multipath does not work correctly in ‘Legacy BIOS Mode’.
  • This product corrects an issue where the virtual World Wide Port Name(WWPN)/World Wide Node Name(WWNN) are not programmed properly when applying the OneView Server Profile.
  • This product addresses an issue where the user sees the error message "Unable to find a FibreChannel boot source for server" in OneView when applying the Server Profile with Fibre Channel network paths configured.
Enhancements

  • The default 'Boot Retry Count' has been increased from 'No Retry' to '6.'
  • Configuration settings are now localized.

Version:2.20.4 (25 Sep 2017)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where a network adapter cannot be re-added to a NIC bond after being removed from the bond.

This product addresses an issue where adapters are not reporting the correct temperature in the Integrated Lights Out (iLO) webpage.

This product addresses an issue where the value set for Maximum Transmission Unit (MTU) setting wasn't preserved and instead gets reverted back to default value on system reboot.

Enhancements

This product now supports Red Hat Enterprise Linux 7 Update 4.
This product now supports SUSE Linux Enterprise Server 12 SP3.


Version:2.19.22 (12 Jul 2017)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where the system boots to an FCoE target when the FCoE ports are marked as “Not Bootable” in the OneView profile.

This product addresses an issue booting to an iSCSI target fails when the target is configured with a sixteen character long mutual Challenge Handshake Authentication Protocol (CHAP) secret.

This product addresses an issue where a network adapter’s configuration settings are not reset to defaults when the adapter is moved to a different slot and the system is booted in ‘Legacy BIOS Mode’.

This product addresses an issue where the system’s power-on self-test (POST) duration is extended when a single interconnect module (ICM) is installed in the enclosure and used to configure the logical interconnect group (LIG).

This product addresses an issue where the configuration settings of the HPE Synergy 3820C 10/20Gb Converged Network Adapter revert to the default values after a system restart.

This product addresses an issue where booting to an iSCSI target fails intermittently across multiple platform reboots.

This product addresses an issue where OneView displays the downlink port state as “Linked” for a network adapter that is disabled in the OS.

This product addresses an issue where a firmware update fails with a "segfault" error.


Version:2.18.44 (24 Oct 2016)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where the iSCSI and FCoE configuration menus are displayed after NPAR is enabled.

This product addresses an issue where expected network devices don't appear in the Legacy BIOS Boot Order menu.

Enhancements

This product now supports the following network adapters:

  • HPE Synergy 3820C 10/20Gb Converged Network Adapter
  • HPE Synergy 10Gb 2-port 2820C Converged Network Adapter

Version:2.18.1 (26 Sep 2016)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product addresses an issue where the iSCSI and FCoE configuration menus are displayed after NPAR is enabled.

This product addresses an issue where expected network devices don't appear in the Legacy BIOS Boot Order menu.

Enhancements

This product now supports the HPE FlexFabric 10Gb 4-port 536FLR-T Adapter.


Version:2.17.16 (1 Apr 2016)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product corrects an issue where Boot from SAN in Legacy mode fails (hang observed during OS boot) because the FCoE ROM doesn't correctly honor the link status set by the Virtual Connect Manager.

This product corrects an issue where UEFI FCoE boot path sends incorrect notification to Management Firmware (MFW) about a virtual function link change, which eventually results in a deadlock with virtual link down.

This product corrects an issue where the fallback Boot from SAN fails even though each port is mapped to a different Virtual Connect Bay and only one of the bays is powered off.

This product corrects an issue where the Smartlink function does not work properly in FCoE SAN boot environment when server 'Boot Mode' is 'Legacy BIOS Mode.'

This product corrects an issue where the FCoE UEFI driver is unable to find LUNs when multiple FCoE VLANs are enabled.

Enhancements

This product now supports the HPE StoreFabric CN1100R-T Converged Network Adapter.

This product now provides the capability of converting an 'HP FlexFabric 10Gb 2-port 533FLR-T Adapter' into a Converged Network Adapter.


Version:2.16.20 (1 Oct 2015)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This product now supports Red Hat Enterprise Linux 6 Update 7.

This product now supports SUSE LINUX Enterprise Server 11 SP4.


Version:2.15.19 (15 Jun 2015)
Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


This firmware provides a new option in the NIC ROM-Based Setup Utility (RBSU) menu (HP’s UEFI System Utilities – F9 at POST) to allow enabling and disabling of HP shared memory features.


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.