Printable version

Drivers & software

* RECOMMENDED * HPE MSA 1040/2040 and P2000 G3 300GB, 450GB and 600GB 12G SAS 15K rpm SFF Drive Models (EH0300JDXBA, EH0450JDXBB and EH0600JDXBC) Hard Drive Firmware

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD3(13 Oct 2016)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0
Multi-part download
File name: HP_EH0300JDXBA_HPD3.fla (832 KB)
File name: HP_EH0450JDXBB_HPD3.fla (832 KB)
File name: HP_EH0600JDXBC_HPD3.fla (832 KB)
The firmware available in this download is specifically packaged for flashing the SFF hard drive models EH0300JDXBA (300GB 12G SAS 15K), EH0450JDXBB (450GB 12G SAS 15K) and EH0600JDXBC (600GB 12G SAS 15K) when configured in HPE MSA 1040/2040 and P2000 G3 Storage Arrays.

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following enhancement was added to this version of firmware:

  • Reliability enhancement for applications that write data to a narrow range of tracks.

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

To ensure the integrity of your download, HPE recommends verifying your results with the following MD5 Checksum values:

ac17271f13d26ab93090186c76d11634 HP_EH0300JDXBA_HPD3.fla
f323bfd3fea75f6249c68e52fe1e89f8 HP_EH0450JDXBB_HPD3.fla
ae3f70dd9afa8ede107819589dba1fd9 HP_EH0600JDXBC_HPD3.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware file in a temporary directory.
  2. Stop I/O to vdisks before starting the firmware update.
  3. Login to the SMU. For SMU [v2] select Tools > Update Firmware and for SMU [v3] go to System > Actions > Update Firmware > Update Disk Drives. A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click Install Disk Firmware File or if using SMU [v3] click on OK button.
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.

Installation instructions using FTP: 

Using the SMU, prepare to use FTP:

  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP service is enabled.
  • Verify that the user you will login, has permission to use the FTP interface and manage access rights.

Obtain address of the disks:

  • Obtain the address of each disk to be loaded in the form (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
  • Note: In SMU [v2], the disk addresses are displayed by clicking on each enclosure in the Configuration View, present in the left pane and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID', 'Slot' and 'Revision'. In SMU [v3], System->Front and put cursor on disk,Tool tip shows the location of the disk.
  • Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'.

Instructions for updating disk firmware using FTP:

  1. Stop all I/O to vdisks before starting the firmware update.
  2. Place the downloaded firmware file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. Enter ftp <ip address>. (For example: ftp 10.1.0.9)
  5. Login via FTP with username and password having manage access rights
  6. To update a specific drive, type "put FILENAME disk:ENCLOSURE-ID:SLOT-NUMBER" where FILENAME is the name of new firmware image to load, ENCLOSURE-ID is the enclosure number and SLOT-NUMBER is the slot number of the drive in the enclosure.
  7. It typically takes several minutes for the firmware update progress messages to be displayed in this FTP interface during this time. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.
  8. Repeat steps 6-7 for each disk to update in each enclosure.
  9. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE MSA 2042 SAN SFF Storage   
  • HPE MSA 2042 SAS SFF Storage   
  • HPE MSA 2040 SAN SFF Storage    
  • HPE MSA 2040 SAS SFF Storage  
  • HPE MSA 1040 SAN SFF Storage      
  • HPE MSA 1040 SAS SFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 SAS MSA Dual Controller SFF Array System
  • HP P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.
Version:HPD5 (13 Apr 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fix was added to this version of firmware:

  • Corrected Activity LED behavior on HPE drive carrier.

Version:HPD3 (13 Oct 2016)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following enhancement was added to this version of firmware:

  • Reliability enhancement for applications that write data to a narrow range of tracks.

Type: Firmware - SAS Storage Disk
Version: HPD3(13 Oct 2016)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0

Description

The firmware available in this download is specifically packaged for flashing the SFF hard drive models EH0300JDXBA (300GB 12G SAS 15K), EH0450JDXBB (450GB 12G SAS 15K) and EH0600JDXBC (600GB 12G SAS 15K) when configured in HPE MSA 1040/2040 and P2000 G3 Storage Arrays.

Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following enhancement was added to this version of firmware:

  • Reliability enhancement for applications that write data to a narrow range of tracks.

Installation Instructions

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

To ensure the integrity of your download, HPE recommends verifying your results with the following MD5 Checksum values:

ac17271f13d26ab93090186c76d11634 HP_EH0300JDXBA_HPD3.fla
f323bfd3fea75f6249c68e52fe1e89f8 HP_EH0450JDXBB_HPD3.fla
ae3f70dd9afa8ede107819589dba1fd9 HP_EH0600JDXBC_HPD3.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware file in a temporary directory.
  2. Stop I/O to vdisks before starting the firmware update.
  3. Login to the SMU. For SMU [v2] select Tools > Update Firmware and for SMU [v3] go to System > Actions > Update Firmware > Update Disk Drives. A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click Install Disk Firmware File or if using SMU [v3] click on OK button.
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.

Installation instructions using FTP: 

Using the SMU, prepare to use FTP:

  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP service is enabled.
  • Verify that the user you will login, has permission to use the FTP interface and manage access rights.

Obtain address of the disks:

  • Obtain the address of each disk to be loaded in the form (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
  • Note: In SMU [v2], the disk addresses are displayed by clicking on each enclosure in the Configuration View, present in the left pane and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID', 'Slot' and 'Revision'. In SMU [v3], System->Front and put cursor on disk,Tool tip shows the location of the disk.
  • Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'.

Instructions for updating disk firmware using FTP:

  1. Stop all I/O to vdisks before starting the firmware update.
  2. Place the downloaded firmware file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. Enter ftp <ip address>. (For example: ftp 10.1.0.9)
  5. Login via FTP with username and password having manage access rights
  6. To update a specific drive, type "put FILENAME disk:ENCLOSURE-ID:SLOT-NUMBER" where FILENAME is the name of new firmware image to load, ENCLOSURE-ID is the enclosure number and SLOT-NUMBER is the slot number of the drive in the enclosure.
  7. It typically takes several minutes for the firmware update progress messages to be displayed in this FTP interface during this time. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.
  8. Repeat steps 6-7 for each disk to update in each enclosure.
  9. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

Release Notes

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE MSA 2042 SAN SFF Storage   
  • HPE MSA 2042 SAS SFF Storage   
  • HPE MSA 2040 SAN SFF Storage    
  • HPE MSA 2040 SAS SFF Storage  
  • HPE MSA 1040 SAN SFF Storage      
  • HPE MSA 1040 SAS SFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 SAS MSA Dual Controller SFF Array System
  • HP P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array

Important

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Revision History

Version:HPD5 (13 Apr 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fix was added to this version of firmware:

  • Corrected Activity LED behavior on HPE drive carrier.

Version:HPD3 (13 Oct 2016)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following enhancement was added to this version of firmware:

  • Reliability enhancement for applications that write data to a narrow range of tracks.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.