Drivers & software

** CRITICAL ** HPE MSA 1040/2040/1050/2050 960GB, 1.92TB, 400GB, 800GB, 1.6TB and 3.2TB 12G SAS SSD SFF Drive Models (VO000960JWTBK, VO001920JWTBL, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT and MO003200JWTBU) Hard Drive Firmware

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD5(20 Jun 2019)
Operating System(s): Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Microsoft Windows Server 2019
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
SUSE Linux Enterprise Server 15
VMware vSphere 5.5
VMware vSphere 6.0
VMware vSphere 6.5
Multi-part download
File name: HPE_MO000400JWTBQ_HPD5.fla (1.1 MB)
File name: HPE_MO000800JWTBR_HPD5.fla (1.1 MB)
File name: HPE_MO001600JWTBT_HPD5.fla (1.1 MB)
File name: HPE_MO003200JWTBU_HPD5.fla (1.1 MB)
File name: HPE_VO000960JWTBK_HPD5.fla (1.1 MB)
File name: HPE_VO001920JWTBL_HPD5.fla (1.1 MB)
The firmware available in this download is specifically packaged for flashing the SFF hard drive models VO000960JWTBK (960GB 12G SAS SSD), VO001920JWTBL (1.92TB 12G SAS SSD), MO000400JWTBQ (400GB 12G SAS SSD), MO000800JWTBR (800GB 12G SAS SSD), MO001600JWTBT (1.6TB 12G SAS SSD) and MO003200JWTBU (3.2TB 12G SAS SSD) when configured in HPE MSA 1040/2040/1050/2050 Storage Array.

Following enhancement was added to this version of the firmware:

  • The new firmware improves robustness during dual port heavy workload environments for both runtime and after sudden power off events.

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

25b1af2ebe4831a15a5aa676078d4b9fad8c21ef88a8bc92be972ac7e35c855c HPE_MO000400JWTBQ_HPD5.fla
9c08ed038c9de56ee9379259fcaa6ea199ec55eaee4c68d779b2f7eb7b55958d HPE_VO001920JWTBL_HPD5.fla
7f1a00165e89c1199a71df7f1f60fcbc76503a4bf32d5e87410a981217a69cce HPE_VO000960JWTBK_HPD5.fla
2a347347e65b5ef7112f92be4bedd8a2b7dff907d10bda0ca9d255a4841aff3c HPE_MO001600JWTBT_HPD5.fla
6a6749db996478bfe7635a6834c746f8bd1ff23988d2cb6407b47caf5073ef9a HPE_MO000800JWTBR_HPD5.fla
c3477e4ae237dd563313b2c3b3f53128f0f635cdfca3024d0e0a96b85dfc0c62 HPE_MO003200JWTBU_HPD5.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware file in a temporary directory.
  2. Stop I/O to controller before starting the firmware update.
  3. Login to the SMU. For SMU v3 (MSA 1040, MSA 2040, MSA 1050 and MSA 2050) go to System -> Actions -> Update Firmware -> Update Disk Drives or for SMU v2 (MSA 1040 and MSA 2040) select Tools -> Update Firmware. A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click OK button, or if using SMU v2 click Install Disk Firmware File.
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.

Installation instructions using FTP or SFTP:

Using the SMU, prepare to use FTP or SFTP:

  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP or SFTP service is enabled.
  • Verify that the user has permission to use the FTP interface and manage access rights.

Obtain address of the disks:

  • Obtain the address of each disk to be loaded in the form (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
    Note: In SMU v3, System->Front and put cursor on disk,Tool tip shows the location of the disk.  In SMU v2, the disk addresses are displayed by clicking on each enclosure in the Configuration View, present in the left pane and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID', 'Slot' and 'Revision'.
    Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'.

Obtain SFTP port number :

  • In CLI, to know the SFTP port number, execute “show protocols” command.
  • In SMU , go to Home->Action-> Configuration Wizard-> Enable system-management services  and check the SFTP port number.

Instructions for updating disk firmware using FTP or SFTP:

  1. Stop all I/O to controller before starting the firmware update.
  2. Place the downloaded firmware file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. To flash using ftp, enter ftp <ip address>. (For example: ftp 10.1.0.9) for Windows and Linux OS.
  5. To flash using sftp, enter sftp -P <sftp port number>  <user>@<controller-network-address>. (For example: sftp -P 1022 ftp@10.1.0.9) for Linux OS. A 3rd party SFTP client application is required to flash via SFTP from Windows, eg. CURL executable.
  6. Login via FTP or SFTP with username and password having manage access role
  7. To update a specific drive, type "put FILENAME disk:ENCLOSURE-ID:SLOT-NUMBER" where FILENAME is the name of new firmware image to load, ENCLOSURE-ID is the enclosure number and SLOT-NUMBER is the slot number of the drive in the enclosure.
  8. It typically takes several minutes for the firmware update progress to complete. Messages will be displayed in the FTP interface during this time. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.
  9. Repeat steps 6-7 for each disk to update in each enclosure.
  10. Quit the FTP or SFTP session.
  11. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

NOTE:

  • Only HPE MSA 1050 and 2050 storage arrays have support for SFTP.

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE MSA 1040 SAN SFF Storage
  • HPE MSA 1040 SAS SFF Storage
  • HPE MSA 2040 SAN SFF Storage
  • HPE MSA 2040 SAS SFF Storage
  • HPE MSA 2042 SAN SFF Storage
  • HPE MSA 2042 SAS SFF Storage
  • HPE MSA 1050 SAN SFF Storage
  • HPE MSA 1050 SAS SFF Storage  
  • HPE MSA 2050 SAN SFF Storage
  • HPE MSA 2050 SAS SFF Storage  
  • HPE MSA 2052 SAN SFF Storage
  • HPE MSA 2052 SAS SFF Storage
  • HPE MSA 2050 SFF Disk Enclosure

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Following fix was added to this version of firmware:

  • Firmware version HPD5 fixes an issue where drive may fail with command timeout messages.  This condition may occur within a few days of initial use if a very small amount of data is written to the drives and they are left powered on without additional data being written to the drive.

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.
Version:HPD7 (25 Jul 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fix was added to this version of firmware:

  • Improved performance during a raid 5 drive rebuild.

Version:HPD5 (20 Jun 2019)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Following fix was added to this version of firmware:

  • Firmware version HPD5 fixes an issue where drive may fail with command timeout messages.  This condition may occur within a few days of initial use if a very small amount of data is written to the drives and they are left powered on without additional data being written to the drive.
Enhancements

Following enhancement was added to this version of the firmware:

  • The new firmware improves robustness during dual port heavy workload environments for both runtime and after sudden power off events.

Type: Firmware - SAS Storage Disk
Version: HPD5(20 Jun 2019)
Operating System(s):
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Microsoft Windows Server 2019
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
SUSE Linux Enterprise Server 15
VMware vSphere 5.5
VMware vSphere 6.0
VMware vSphere 6.5

Description

The firmware available in this download is specifically packaged for flashing the SFF hard drive models VO000960JWTBK (960GB 12G SAS SSD), VO001920JWTBL (1.92TB 12G SAS SSD), MO000400JWTBQ (400GB 12G SAS SSD), MO000800JWTBR (800GB 12G SAS SSD), MO001600JWTBT (1.6TB 12G SAS SSD) and MO003200JWTBU (3.2TB 12G SAS SSD) when configured in HPE MSA 1040/2040/1050/2050 Storage Array.

Enhancements

Following enhancement was added to this version of the firmware:

  • The new firmware improves robustness during dual port heavy workload environments for both runtime and after sudden power off events.

Installation Instructions

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

25b1af2ebe4831a15a5aa676078d4b9fad8c21ef88a8bc92be972ac7e35c855c HPE_MO000400JWTBQ_HPD5.fla
9c08ed038c9de56ee9379259fcaa6ea199ec55eaee4c68d779b2f7eb7b55958d HPE_VO001920JWTBL_HPD5.fla
7f1a00165e89c1199a71df7f1f60fcbc76503a4bf32d5e87410a981217a69cce HPE_VO000960JWTBK_HPD5.fla
2a347347e65b5ef7112f92be4bedd8a2b7dff907d10bda0ca9d255a4841aff3c HPE_MO001600JWTBT_HPD5.fla
6a6749db996478bfe7635a6834c746f8bd1ff23988d2cb6407b47caf5073ef9a HPE_MO000800JWTBR_HPD5.fla
c3477e4ae237dd563313b2c3b3f53128f0f635cdfca3024d0e0a96b85dfc0c62 HPE_MO003200JWTBU_HPD5.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware file in a temporary directory.
  2. Stop I/O to controller before starting the firmware update.
  3. Login to the SMU. For SMU v3 (MSA 1040, MSA 2040, MSA 1050 and MSA 2050) go to System -> Actions -> Update Firmware -> Update Disk Drives or for SMU v2 (MSA 1040 and MSA 2040) select Tools -> Update Firmware. A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click OK button, or if using SMU v2 click Install Disk Firmware File.
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.

Installation instructions using FTP or SFTP:

Using the SMU, prepare to use FTP or SFTP:

  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP or SFTP service is enabled.
  • Verify that the user has permission to use the FTP interface and manage access rights.

Obtain address of the disks:

  • Obtain the address of each disk to be loaded in the form (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
    Note: In SMU v3, System->Front and put cursor on disk,Tool tip shows the location of the disk.  In SMU v2, the disk addresses are displayed by clicking on each enclosure in the Configuration View, present in the left pane and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID', 'Slot' and 'Revision'.
    Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'.

Obtain SFTP port number :

  • In CLI, to know the SFTP port number, execute “show protocols” command.
  • In SMU , go to Home->Action-> Configuration Wizard-> Enable system-management services  and check the SFTP port number.

Instructions for updating disk firmware using FTP or SFTP:

  1. Stop all I/O to controller before starting the firmware update.
  2. Place the downloaded firmware file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. To flash using ftp, enter ftp <ip address>. (For example: ftp 10.1.0.9) for Windows and Linux OS.
  5. To flash using sftp, enter sftp -P <sftp port number>  <user>@<controller-network-address>. (For example: sftp -P 1022 ftp@10.1.0.9) for Linux OS. A 3rd party SFTP client application is required to flash via SFTP from Windows, eg. CURL executable.
  6. Login via FTP or SFTP with username and password having manage access role
  7. To update a specific drive, type "put FILENAME disk:ENCLOSURE-ID:SLOT-NUMBER" where FILENAME is the name of new firmware image to load, ENCLOSURE-ID is the enclosure number and SLOT-NUMBER is the slot number of the drive in the enclosure.
  8. It typically takes several minutes for the firmware update progress to complete. Messages will be displayed in the FTP interface during this time. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.
  9. Repeat steps 6-7 for each disk to update in each enclosure.
  10. Quit the FTP or SFTP session.
  11. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

NOTE:

  • Only HPE MSA 1050 and 2050 storage arrays have support for SFTP.

Release Notes

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE MSA 1040 SAN SFF Storage
  • HPE MSA 1040 SAS SFF Storage
  • HPE MSA 2040 SAN SFF Storage
  • HPE MSA 2040 SAS SFF Storage
  • HPE MSA 2042 SAN SFF Storage
  • HPE MSA 2042 SAS SFF Storage
  • HPE MSA 1050 SAN SFF Storage
  • HPE MSA 1050 SAS SFF Storage  
  • HPE MSA 2050 SAN SFF Storage
  • HPE MSA 2050 SAS SFF Storage  
  • HPE MSA 2052 SAN SFF Storage
  • HPE MSA 2052 SAS SFF Storage
  • HPE MSA 2050 SFF Disk Enclosure

Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Following fix was added to this version of firmware:

  • Firmware version HPD5 fixes an issue where drive may fail with command timeout messages.  This condition may occur within a few days of initial use if a very small amount of data is written to the drives and they are left powered on without additional data being written to the drive.

Important

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Revision History

Version:HPD7 (25 Jul 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fix was added to this version of firmware:

  • Improved performance during a raid 5 drive rebuild.

Version:HPD5 (20 Jun 2019)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


Following fix was added to this version of firmware:

  • Firmware version HPD5 fixes an issue where drive may fail with command timeout messages.  This condition may occur within a few days of initial use if a very small amount of data is written to the drives and they are left powered on without additional data being written to the drive.
Enhancements

Following enhancement was added to this version of the firmware:

  • The new firmware improves robustness during dual port heavy workload environments for both runtime and after sudden power off events.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.