Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Windows - HP MSA 1040/2040, P2000 G3 and MSA2000 G2 450GB 6G SAS 15K rpm LFF Drive Model (ST3450857SS)

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: 0008 (A)(6 Nov 2014)
Operating System(s): Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
File name: cp022189.exe (2.5 MB)
This Windows Smart Component contains a firmware update for the LFF hard drive model ST3450857SS(450GB 15K SAS 6G) in HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

Following enhancement were added in 0008:

  • Added Support for MSA 1040/2040 Arrays.

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

b0bf84a4658d1ad85f014709bc3496bc cp022189.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of that username


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0008(A) is not necessary if HDDs are currently running 0008 firmware.
Only the Smart Component package digital certificate has been updated for version 0008(A).


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP P2000 G3 10GbE iSCSI MSA Dual Controller LFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller LFF Array System
  • HP P2000 G3 SAS MSA Dual Controller LFF Array System
  • HP P2000 G3 MSA FC Dual Controller LFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller LFF Array
  • HP MSA2000 Single I/O 3.5 inch 12 Drive Enclosure
  • HP MSA2000 Dual I/O 3.5 inch 12 Drive Enclosure
  • HP MSA 2040 LFF Disk Enclosure
  • HP P2000 Dual I/O LFF Drive Enclosure
  • Modular Smart Array 2312sa
  • Modular Smart Array 2312fc
  • Modular Smart Array 2312i
  • HP MSA 2040 SAN Dual Controller LFF Storage
  • HP MSA 2040 SAS Dual Controller LFF Storage
  • HP MSA 1040 2-port 10G iSCSI Dual Controller LFF Storage
  • HP MSA 1040 2-port 1G iSCSI Dual Controller LFF Storage
  • HP MSA 1040 2-port Fibre Channel Dual Controller LFF Storage

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0008(A) is not necessary if HDDs are currently running 0008 firmware.
Only the Smart Component package digital certificate has been updated for version 0008(A).


Following fixes were added in 0008:

  • During SAS 2.0 speed negotiations drive fails to see HARD RESET.
  • Drive does not acknowledge a hard reset and treats the reset as a link reset.
  • Hung Phy during disk reset test.
  • Seeks to the system cylinders dwell for a long time.
  • 04/8087/80 IOEDC error on write.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

Version:000B (6 Oct 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fixes were added to this version of firmware:

  • Hard resets could hang the drive
  • Unexpected power loss/port loss
  • Various issues which would cause the LED to flash
Enhancements

Following enhancement was added to this version of firmware:

  •  Improvements to command processing which improve performance in certain workloads

 


Version:0008 (A) (6 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0008(A) is not necessary if HDDs are currently running 0008 firmware.
Only the Smart Component package digital certificate has been updated for version 0008(A).


Following fixes were added in 0008:

  • During SAS 2.0 speed negotiations drive fails to see HARD RESET.
  • Drive does not acknowledge a hard reset and treats the reset as a link reset.
  • Hung Phy during disk reset test.
  • Seeks to the system cylinders dwell for a long time.
  • 04/8087/80 IOEDC error on write.
Enhancements

Following enhancement were added in 0008:

  • Added Support for MSA 1040/2040 Arrays.

Version:0008 (6 Sep 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


This firmware update resolves the below issues:

  • During SAS 2.0 speed negotiations drive fails to see HARD RESET.
  • Drive does not acknowledge a hard reset and treats the reset as a link reset.
  • Hung Phy during disk reset test.
  • Seeks to the system cylinders dwell for a long time.
  • 04/8087/80 IOEDC error on write.

Version:0006 (14 Jul 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 products


Type: Firmware - SAS Storage Disk
Version: 0008 (A)(6 Nov 2014)
Operating System(s):
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2

Description

This Windows Smart Component contains a firmware update for the LFF hard drive model ST3450857SS(450GB 15K SAS 6G) in HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

Enhancements

Following enhancement were added in 0008:

  • Added Support for MSA 1040/2040 Arrays.

Installation Instructions

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

b0bf84a4658d1ad85f014709bc3496bc cp022189.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of that username


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0008(A) is not necessary if HDDs are currently running 0008 firmware.
Only the Smart Component package digital certificate has been updated for version 0008(A).


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP P2000 G3 10GbE iSCSI MSA Dual Controller LFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller LFF Array System
  • HP P2000 G3 SAS MSA Dual Controller LFF Array System
  • HP P2000 G3 MSA FC Dual Controller LFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller LFF Array
  • HP MSA2000 Single I/O 3.5 inch 12 Drive Enclosure
  • HP MSA2000 Dual I/O 3.5 inch 12 Drive Enclosure
  • HP MSA 2040 LFF Disk Enclosure
  • HP P2000 Dual I/O LFF Drive Enclosure
  • Modular Smart Array 2312sa
  • Modular Smart Array 2312fc
  • Modular Smart Array 2312i
  • HP MSA 2040 SAN Dual Controller LFF Storage
  • HP MSA 2040 SAS Dual Controller LFF Storage
  • HP MSA 1040 2-port 10G iSCSI Dual Controller LFF Storage
  • HP MSA 1040 2-port 1G iSCSI Dual Controller LFF Storage
  • HP MSA 1040 2-port Fibre Channel Dual Controller LFF Storage

Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0008(A) is not necessary if HDDs are currently running 0008 firmware.
Only the Smart Component package digital certificate has been updated for version 0008(A).


Following fixes were added in 0008:

  • During SAS 2.0 speed negotiations drive fails to see HARD RESET.
  • Drive does not acknowledge a hard reset and treats the reset as a link reset.
  • Hung Phy during disk reset test.
  • Seeks to the system cylinders dwell for a long time.
  • 04/8087/80 IOEDC error on write.

Important

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040, P2000 G3 and MSA2000 G2 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array 2000 Family reference guide. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flashing summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040, P2000 G3 and MSA2000 G2 Storage Arrays.

Revision History

Version:000B (6 Oct 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fixes were added to this version of firmware:

  • Hard resets could hang the drive
  • Unexpected power loss/port loss
  • Various issues which would cause the LED to flash
Enhancements

Following enhancement was added to this version of firmware:

  •  Improvements to command processing which improve performance in certain workloads

 


Version:0008 (A) (6 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware 0008(A) is not necessary if HDDs are currently running 0008 firmware.
Only the Smart Component package digital certificate has been updated for version 0008(A).


Following fixes were added in 0008:

  • During SAS 2.0 speed negotiations drive fails to see HARD RESET.
  • Drive does not acknowledge a hard reset and treats the reset as a link reset.
  • Hung Phy during disk reset test.
  • Seeks to the system cylinders dwell for a long time.
  • 04/8087/80 IOEDC error on write.
Enhancements

Following enhancement were added in 0008:

  • Added Support for MSA 1040/2040 Arrays.

Version:0008 (6 Sep 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


This firmware update resolves the below issues:

  • During SAS 2.0 speed negotiations drive fails to see HARD RESET.
  • Drive does not acknowledge a hard reset and treats the reset as a link reset.
  • Hung Phy during disk reset test.
  • Seeks to the system cylinders dwell for a long time.
  • 04/8087/80 IOEDC error on write.

Version:0006 (14 Jul 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 products


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.