** CRITICAL ** Online ROM Flash Component for Windows (x64) - EG1800JFHMH Drives

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD6(16 Nov 2017)
Operating System(s): Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Multi-part download
File name: cp033430.compsig (2.0 KB)
File name: cp033430.exe (4.0 MB)
File name: cp033430.md5 (48 Bytes)
This x64 Smart Component provides firmware for the following drive models: EG1800JFHMH

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

ea5c8e92fd09db926d71bce002162f7c8de9a2d2c028b8e49eb75f919df75e60 cp033430.md5
29f9abea8e676e682ceffa32ab71b7bfa4ef1e365f2fe7855dfdf969af84e58d cp033430.compsig
57ab3a6b927995087174a61c17f997e91f258b7bdd4c4a2528e0cf4da2f080d0 cp033430.exe

Reboot Requirement:
Reboot may be required after installation for updates to take effect and hardware stability to be maintained.


Installation:

To update firmware from Windows operating system on target server:

  • Place the Smart Component in a temporary directory.
  • Double-click on the Smart Component.
  • Follow the directions given by the Smart Component.
  • Reboot your system if you would like the update to take effect immediately.

To use Smart Update Manager from the Service Pack for ProLiant:

  • Place the desired firmware to be updated in the directory, \<SPP root folder>\packages.
  • Run launch_sum.bat script which is found in the root folder of the SPP.
  • Follow the instructions on the screen.

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.

Notes:

Deliverable Name:
    Online ROM Flash Component for Windows (x64) - EG1800JFHMH Drives

Release Version and/or Date:
     HPD6

Last Recommended or Critical Version:
     HPD6

Previous Version of Firmware:
     HPD5

Firmware Dependency:
     None

Enhancements/New Features:
     None

Problems Fixed:

  • This firmware eliminates a data integrity risk when an unaligned Write and Verify command is sent to a bad sector. During these conditions there is a potential for data intended to be written to disk to fail to be written.

Known Issues:
     None


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.

Problems Fixed:

  • This firmware eliminates a data integrity risk when an unaligned Write and Verify command is sent to a bad sector. During these conditions there is a potential for data intended to be written to disk to fail to be written.
Version:HPD6 (16 Nov 2017)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.

Problems Fixed:

  • This firmware eliminates a data integrity risk when an unaligned Write and Verify command is sent to a bad sector. During these conditions there is a potential for data intended to be written to disk to fail to be written.

Version:HPD5(B) (12 Jul 2017)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.
  • Customers who already installed firmware version HPD5 do not need to update to HPD5 (B).

Problems Fixed:

  • Fixes a data integrity risk which could occur during 4k or greater unaligned writes while the device incurs a smart trip or smart warning event. During these conditions there is a potential for data intended to be written directly to disk to fail to be written.
Enhancements

Enhancements/New Features:

  • Changes Light Emitting Diode (LED) behavior to match Hewlett Packard Enterprise specification.
  • Strengthens link acquisition algorithm.
  • Adds support for HPE ProLiant Gen10 servers.

Version:HPD5 (23 May 2017)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.

Problems Fixed:

  • Fixes a data integrity risk which could occur during 4k or greater unaligned writes while the device incurs a smart trip or smart warning event. During these conditions there is a potential for data intended to be written directly to disk to fail to be written.
Enhancements

Enhancements/New Features:

  • Changes Light Emitting Diode (LED) behavior to match Hewlett Packard Enterprise specification.
  • Strengthens link acquisition algorithm.

Type: Firmware - SAS Storage Disk
Version: HPD6(16 Nov 2017)
Operating System(s):
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016

Description

This x64 Smart Component provides firmware for the following drive models: EG1800JFHMH

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

ea5c8e92fd09db926d71bce002162f7c8de9a2d2c028b8e49eb75f919df75e60 cp033430.md5
29f9abea8e676e682ceffa32ab71b7bfa4ef1e365f2fe7855dfdf969af84e58d cp033430.compsig
57ab3a6b927995087174a61c17f997e91f258b7bdd4c4a2528e0cf4da2f080d0 cp033430.exe

Reboot Requirement:
Reboot may be required after installation for updates to take effect and hardware stability to be maintained.


Installation:

To update firmware from Windows operating system on target server:

  • Place the Smart Component in a temporary directory.
  • Double-click on the Smart Component.
  • Follow the directions given by the Smart Component.
  • Reboot your system if you would like the update to take effect immediately.

To use Smart Update Manager from the Service Pack for ProLiant:

  • Place the desired firmware to be updated in the directory, \<SPP root folder>\packages.
  • Run launch_sum.bat script which is found in the root folder of the SPP.
  • Follow the instructions on the screen.

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.

Notes:

Deliverable Name:
    Online ROM Flash Component for Windows (x64) - EG1800JFHMH Drives

Release Version and/or Date:
     HPD6

Last Recommended or Critical Version:
     HPD6

Previous Version of Firmware:
     HPD5

Firmware Dependency:
     None

Enhancements/New Features:
     None

Problems Fixed:

  • This firmware eliminates a data integrity risk when an unaligned Write and Verify command is sent to a bad sector. During these conditions there is a potential for data intended to be written to disk to fail to be written.

Known Issues:
     None


Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.

Problems Fixed:

  • This firmware eliminates a data integrity risk when an unaligned Write and Verify command is sent to a bad sector. During these conditions there is a potential for data intended to be written to disk to fail to be written.

Revision History

Version:HPD6 (16 Nov 2017)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.

Problems Fixed:

  • This firmware eliminates a data integrity risk when an unaligned Write and Verify command is sent to a bad sector. During these conditions there is a potential for data intended to be written to disk to fail to be written.

Version:HPD5(B) (12 Jul 2017)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.
  • Customers who already installed firmware version HPD5 do not need to update to HPD5 (B).

Problems Fixed:

  • Fixes a data integrity risk which could occur during 4k or greater unaligned writes while the device incurs a smart trip or smart warning event. During these conditions there is a potential for data intended to be written directly to disk to fail to be written.
Enhancements

Enhancements/New Features:

  • Changes Light Emitting Diode (LED) behavior to match Hewlett Packard Enterprise specification.
  • Strengthens link acquisition algorithm.
  • Adds support for HPE ProLiant Gen10 servers.

Version:HPD5 (23 May 2017)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.

  • Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or a ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
  • Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for Proliant and Smart Update Manager.

Problems Fixed:

  • Fixes a data integrity risk which could occur during 4k or greater unaligned writes while the device incurs a smart trip or smart warning event. During these conditions there is a potential for data intended to be written directly to disk to fail to be written.
Enhancements

Enhancements/New Features:

  • Changes Light Emitting Diode (LED) behavior to match Hewlett Packard Enterprise specification.
  • Strengthens link acquisition algorithm.