Printable version

Drivers & software

* RECOMMENDED * HP StorageWorks P2000/MSA2000 500GB 6G SAS 7.2K rpm SFF Hard Drive (MM0500FAMYT) Firmware

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD4(4 May 2011)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Red Hat Enterprise Linux 4 (AMD64/EM64T)
Red Hat Enterprise Linux 4 (Itanium)
Red Hat Enterprise Linux 4 (x86)
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Solaris 10 for x86 Systems
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
VMware ESX/ESXi 4.0
VMware ESX/ESXi Server 3.5
File name: HP_MM0500FAMYT_HPD4.fla (998 KB)
The firmware available in this download is specifically packaged for flashing the SFF hard drive model MM0500FAMYT (500GB 7K SAS 6G) when configured in HP StorageWorks P2000 G3 MSA and MSA2000 G2 storage arrays. Please DO NOT use this package for flashing the drives if they are in any other configurations including MSA2000 G1 array configurations.

Prerequisites:
WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE: Drives of the same model in the storage system must have the same firmware revision.

NOTE: To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

96e5f47344b37775efc0c49b5ea03fb9a47f3f58481a19894420ec72f62192fc HP_MM0500FAMYT_HPD4.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:
Installation instructions using Storage Management Utility (SMU)

  1. Place the downloaded firmware package in a temporary directory.
  2. Locate the firmware file in the extracted folder.
  3. Stop I/O to vdisks before starting the firmware update.
  4. Log in to the SMU and, in the Configuration View panel, right-click the system and select Tools > Update Firmware. A table displays currently installed firmware versions.
  5. Select the drives to update.
  6. Click Browse and select the firmware file to install.
  7. Click Install Disk Firmware File. Wait for progress messages to specify that the update is complete.
  8. In the SMU display, verify that the proper firmware version appears for each module.
  9. If the old firmware version is still displayed in the SMU, cycle power on the enclosure. And then log in to the SMU to verify the firmware version.
Installation instructions using FTP
  1. Place the downloaded firmware package in a temporary directory.

  2. Locate the firmware file in the extracted folder.

  3. Do one of the following:

    1. To update all drives of the type that the firmware applies to, proceed to the next step.

    2. To update specific drives, determine the enclosure number and slot number of the drive.

  4. Using the SMU, prepare to use FTP:

    1. Determine the network-port IP addresses of the system controllers.

    2. Verify that the system FTP service is enabled.

    3. Verify that the user you will log in as has permission to use the FTP interface and has manage access rights.

  5. Stop all I/O to vdisks before starting the firmware update.

  6. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.

    1. Enter ftp <controller-network-address>. (For example: ftp 10.1.0.9)

    2. Log in as an FTP user. (P2000 environments: user = ftp password = !ftp; MSA2000 environments: user = ftp password = flash)

    3. To update a specific drive, enter: put <firmware-file> disk:enclosure-ID>:slot-number flash.

  7. If needed, repeat these steps to load the firmware on additional drives.

  8. Quit the FTP session.

  9. In the SMU display, verify that the proper firmware version appears for each module.

  10. If the old firmware version is still displayed in the SMU, cycle power on the enclosure. And then log in to the SMU to verify the firmware version.


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be temporarily inaccessible and increases the risk of data loss

IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped prior to the upgrade.


Notes:

Deliverable Name:
     HP StorageWorks P2000/MSA2000 500GB 6G SAS 7.2K rpm SFF Hard Drive (MM0500FAMYT) Firmware

Release Version and/or Date:
      HPD4

Last Recommended or Critical Version:
      HPD4

Previous Version of Firmware:
      HPD3

Enhancements/New Features:
     None

Problems Fixed:

  • Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.

Known Issues:
     None


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any P2000 G3 or MSA2000 G2 array controller enclosure.


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.

CAUTION: Updating firmware on drives in a virtual disk causes the drives to be temporarily inaccessible and increases the risk of data loss

IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped prior to the upgrade.
Version:HPD4 (4 May 2011)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.


Version:HPD3 (27 Sep 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Use this firmware to flash supported drives in P2000 G3 MSA and MSA2000 G2 configurations ONLY.

Do not use this firmware to flash the drives if the drives are in any other configurations.


Initial release of specially packaged firmware for use in P2000 G3 MSA and MSA2000 G2 configurations ONLY.


Version:HPDD (18 Feb 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Releasing this with MSA2000 drive wrapper to allow for FTP and SMU update.


Type: Firmware - SAS Storage Disk
Version: HPD4(4 May 2011)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Red Hat Enterprise Linux 4 (AMD64/EM64T)
Red Hat Enterprise Linux 4 (Itanium)
Red Hat Enterprise Linux 4 (x86)
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Solaris 10 for x86 Systems
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
VMware ESX/ESXi 4.0
VMware ESX/ESXi Server 3.5

Description

The firmware available in this download is specifically packaged for flashing the SFF hard drive model MM0500FAMYT (500GB 7K SAS 6G) when configured in HP StorageWorks P2000 G3 MSA and MSA2000 G2 storage arrays. Please DO NOT use this package for flashing the drives if they are in any other configurations including MSA2000 G1 array configurations.

Installation Instructions

Prerequisites:
WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE: Drives of the same model in the storage system must have the same firmware revision.

NOTE: To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

96e5f47344b37775efc0c49b5ea03fb9a47f3f58481a19894420ec72f62192fc HP_MM0500FAMYT_HPD4.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:
Installation instructions using Storage Management Utility (SMU)

  1. Place the downloaded firmware package in a temporary directory.
  2. Locate the firmware file in the extracted folder.
  3. Stop I/O to vdisks before starting the firmware update.
  4. Log in to the SMU and, in the Configuration View panel, right-click the system and select Tools > Update Firmware. A table displays currently installed firmware versions.
  5. Select the drives to update.
  6. Click Browse and select the firmware file to install.
  7. Click Install Disk Firmware File. Wait for progress messages to specify that the update is complete.
  8. In the SMU display, verify that the proper firmware version appears for each module.
  9. If the old firmware version is still displayed in the SMU, cycle power on the enclosure. And then log in to the SMU to verify the firmware version.
Installation instructions using FTP
  1. Place the downloaded firmware package in a temporary directory.

  2. Locate the firmware file in the extracted folder.

  3. Do one of the following:

    1. To update all drives of the type that the firmware applies to, proceed to the next step.

    2. To update specific drives, determine the enclosure number and slot number of the drive.

  4. Using the SMU, prepare to use FTP:

    1. Determine the network-port IP addresses of the system controllers.

    2. Verify that the system FTP service is enabled.

    3. Verify that the user you will log in as has permission to use the FTP interface and has manage access rights.

  5. Stop all I/O to vdisks before starting the firmware update.

  6. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.

    1. Enter ftp <controller-network-address>. (For example: ftp 10.1.0.9)

    2. Log in as an FTP user. (P2000 environments: user = ftp password = !ftp; MSA2000 environments: user = ftp password = flash)

    3. To update a specific drive, enter: put <firmware-file> disk:enclosure-ID>:slot-number flash.

  7. If needed, repeat these steps to load the firmware on additional drives.

  8. Quit the FTP session.

  9. In the SMU display, verify that the proper firmware version appears for each module.

  10. If the old firmware version is still displayed in the SMU, cycle power on the enclosure. And then log in to the SMU to verify the firmware version.


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be temporarily inaccessible and increases the risk of data loss

IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped prior to the upgrade.


Notes:

Deliverable Name:
     HP StorageWorks P2000/MSA2000 500GB 6G SAS 7.2K rpm SFF Hard Drive (MM0500FAMYT) Firmware

Release Version and/or Date:
      HPD4

Last Recommended or Critical Version:
      HPD4

Previous Version of Firmware:
      HPD3

Enhancements/New Features:
     None

Problems Fixed:

  • Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.

Known Issues:
     None


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any P2000 G3 or MSA2000 G2 array controller enclosure.


Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.

Important

CAUTION: Updating firmware on drives in a virtual disk causes the drives to be temporarily inaccessible and increases the risk of data loss

IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped prior to the upgrade.

Revision History

Version:HPD4 (4 May 2011)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.


Version:HPD3 (27 Sep 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Use this firmware to flash supported drives in P2000 G3 MSA and MSA2000 G2 configurations ONLY.

Do not use this firmware to flash the drives if the drives are in any other configurations.


Initial release of specially packaged firmware for use in P2000 G3 MSA and MSA2000 G2 configurations ONLY.


Version:HPDD (18 Feb 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Releasing this with MSA2000 drive wrapper to allow for FTP and SMU update.


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.