Printable version

Drivers & software

HPE MSA 1040/2040/1050/2050 and P2000 G3 600GB and 1.2TB 12G SAS 10K rpm SFF Drive Models (EG000600JWFUV and EG001200JWFVA) Hard Drive Firmware

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD3(2 Aug 2018)
Operating System(s): HP-UX 11.31 (IA)
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware vSphere 6.0
VMware vSphere 6.5
Multi-part download
File name: HP_EG000600JWFUV_HPD3.fla (848 KB)
File name: HP_EG001200JWFVA_HPD3.fla (848 KB)
The firmware available in this download is specifically packaged for flashing the SFF hard drive models EG000600JWFUV (600GB 12G SAS 10K) and EG001200JWFVA (1.2TB 12G SAS 10K) when configured in HPE MSA 1040/2040/1050/2050 and P2000 G3 Storage Arrays.

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

844ca7880b6908ca227a640482f9e77f1b8e83ee9ff37d8672d7c85cf07c46d6 HP_EG000600JWFUV_HPD3.fla
b8434010a5e61aec9811bb038e288655a991aafbc820ebdf545cdb54d2e14c62 HP_EG001200JWFVA_HPD3.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware file in a temporary directory.
  2. Stop I/O to controller before starting the firmware update.
  3. Login to the SMU. For SMU v3 (MSA 1040, MSA 2040, MSA 1050 and MSA 2050) go to System -> Actions -> Update Firmware -> Update Disk Drives or for SMU v2 (P2000 G3, MSA 1040 and MSA 2040) select Tools -> Update Firmware . A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click OK button, or if using SMU v2 click Install Disk Firmware File.
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.

Installation instructions using FTP or SFTP:

Using the SMU, prepare to use FTP or SFTP:

  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP or SFTP service is enabled.
  • Verify that the user has permission to use the FTP interface and manage access rights.

Obtain address of the disks:

  • Obtain the address of each disk to be loaded in the form (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
    Note: In SMU v3, System->Front and put cursor on disk,Tool tip shows the location of the disk.  In SMU v2, the disk addresses are displayed by clicking on each enclosure in the Configuration View, present in the left pane and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID', 'Slot' and 'Revision'.
    Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'.

Obtain SFTP port number :

  • In CLI, to know the SFTP port number, execute “show protocols” command.
  • In SMU , go to Home->Action-> Configuration Wizard-> Enable system-management services  and check the SFTP port number.

Instructions for updating disk firmware using FTP or SFTP:

  1. Stop all I/O to controller before starting the firmware update.
  2. Place the downloaded firmware file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. To flash using ftp, enter ftp <ip address>. (For example: ftp 10.1.0.9) for Windows and Linux OS.
  5. To flash using sftp, enter sftp -P <sftp port number>  <user>@<controller-network-address>. (For example: sftp -P 1022 ftp@10.1.0.9) for Linux OS. A 3rd party SFTP client application is required to flash via SFTP from Windows, eg. CURL executable.
  6. Login via FTP or SFTP with username and password having manage access role
  7. To update a specific drive, type "put FILENAME disk:ENCLOSURE-ID:SLOT-NUMBER" where FILENAME is the name of new firmware image to load, ENCLOSURE-ID is the enclosure number and SLOT-NUMBER is the slot number of the drive in the enclosure.
  8. It typically takes several minutes for the firmware update progress to complete. Messages will be displayed in the FTP interface during this time. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.
  9. Repeat steps 6-7 for each disk to update in each enclosure.
  10. Quit the FTP or SFTP session.
  11. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

NOTE:

  • Only HPE MSA 1050 and 2050 storage arrays have support for SFTP. 

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System      
  • HPE P2000 G3 iSCSI MSA Dual Controller SFF Array System      
  • HPE P2000 G3 SAS MSA Dual Controller SFF Array System      
  • HPE P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System     
  • HPE P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array
  • HPE MSA 1040 SAN SFF Storage
  • HPE MSA 1040 SAS SFF Storage
  • HPE MSA 2040 SAN SFF Storage
  • HPE MSA 2040 SAS SFF Storage
  • HPE MSA 2042 SAN SFF Storage
  • HPE MSA 2042 SAS SFF Storage
  • HPE MSA 1050 SAN SFF Storage
  • HPE MSA 1050 SAS SFF Storage 
  • HPE MSA 2050 SAN SFF Storage
  • HPE MSA 2050 SAS SFF Storage
  • HPE MSA 2052 SAN SFF Storage
  • HPE MSA 2052 SAS SFF Storage
  • HPE MSA 2050 SFF Disk Enclosure

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Following fix was added to this version of firmware:

  • This firmware changes some settings to comply with Microsoft Storage Spaces Certification requirements.

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.
Version:HPD3 (2 Aug 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Following fix was added to this version of firmware:

  • This firmware changes some settings to comply with Microsoft Storage Spaces Certification requirements.

Type: Firmware - SAS Storage Disk
Version: HPD3(2 Aug 2018)
Operating System(s):
HP-UX 11.31 (IA)
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware vSphere 6.0
VMware vSphere 6.5

Description

The firmware available in this download is specifically packaged for flashing the SFF hard drive models EG000600JWFUV (600GB 12G SAS 10K) and EG001200JWFVA (1.2TB 12G SAS 10K) when configured in HPE MSA 1040/2040/1050/2050 and P2000 G3 Storage Arrays.

Installation Instructions

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

844ca7880b6908ca227a640482f9e77f1b8e83ee9ff37d8672d7c85cf07c46d6 HP_EG000600JWFUV_HPD3.fla
b8434010a5e61aec9811bb038e288655a991aafbc820ebdf545cdb54d2e14c62 HP_EG001200JWFVA_HPD3.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware file in a temporary directory.
  2. Stop I/O to controller before starting the firmware update.
  3. Login to the SMU. For SMU v3 (MSA 1040, MSA 2040, MSA 1050 and MSA 2050) go to System -> Actions -> Update Firmware -> Update Disk Drives or for SMU v2 (P2000 G3, MSA 1040 and MSA 2040) select Tools -> Update Firmware . A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click OK button, or if using SMU v2 click Install Disk Firmware File.
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.

Installation instructions using FTP or SFTP:

Using the SMU, prepare to use FTP or SFTP:

  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP or SFTP service is enabled.
  • Verify that the user has permission to use the FTP interface and manage access rights.

Obtain address of the disks:

  • Obtain the address of each disk to be loaded in the form (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
    Note: In SMU v3, System->Front and put cursor on disk,Tool tip shows the location of the disk.  In SMU v2, the disk addresses are displayed by clicking on each enclosure in the Configuration View, present in the left pane and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID', 'Slot' and 'Revision'.
    Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'.

Obtain SFTP port number :

  • In CLI, to know the SFTP port number, execute “show protocols” command.
  • In SMU , go to Home->Action-> Configuration Wizard-> Enable system-management services  and check the SFTP port number.

Instructions for updating disk firmware using FTP or SFTP:

  1. Stop all I/O to controller before starting the firmware update.
  2. Place the downloaded firmware file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. To flash using ftp, enter ftp <ip address>. (For example: ftp 10.1.0.9) for Windows and Linux OS.
  5. To flash using sftp, enter sftp -P <sftp port number>  <user>@<controller-network-address>. (For example: sftp -P 1022 ftp@10.1.0.9) for Linux OS. A 3rd party SFTP client application is required to flash via SFTP from Windows, eg. CURL executable.
  6. Login via FTP or SFTP with username and password having manage access role
  7. To update a specific drive, type "put FILENAME disk:ENCLOSURE-ID:SLOT-NUMBER" where FILENAME is the name of new firmware image to load, ENCLOSURE-ID is the enclosure number and SLOT-NUMBER is the slot number of the drive in the enclosure.
  8. It typically takes several minutes for the firmware update progress to complete. Messages will be displayed in the FTP interface during this time. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.
  9. Repeat steps 6-7 for each disk to update in each enclosure.
  10. Quit the FTP or SFTP session.
  11. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

NOTE:

  • Only HPE MSA 1050 and 2050 storage arrays have support for SFTP. 

Release Notes

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System      
  • HPE P2000 G3 iSCSI MSA Dual Controller SFF Array System      
  • HPE P2000 G3 SAS MSA Dual Controller SFF Array System      
  • HPE P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System     
  • HPE P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array
  • HPE MSA 1040 SAN SFF Storage
  • HPE MSA 1040 SAS SFF Storage
  • HPE MSA 2040 SAN SFF Storage
  • HPE MSA 2040 SAS SFF Storage
  • HPE MSA 2042 SAN SFF Storage
  • HPE MSA 2042 SAS SFF Storage
  • HPE MSA 1050 SAN SFF Storage
  • HPE MSA 1050 SAS SFF Storage 
  • HPE MSA 2050 SAN SFF Storage
  • HPE MSA 2050 SAS SFF Storage
  • HPE MSA 2052 SAN SFF Storage
  • HPE MSA 2052 SAS SFF Storage
  • HPE MSA 2050 SFF Disk Enclosure

Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Following fix was added to this version of firmware:

  • This firmware changes some settings to comply with Microsoft Storage Spaces Certification requirements.

Important

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HPE website and save the file to your local filesystem.

Revision History

Version:HPD3 (2 Aug 2018)
Fixes

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.


Following fix was added to this version of firmware:

  • This firmware changes some settings to comply with Microsoft Storage Spaces Certification requirements.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.