Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Windows - HP MSA 2040 200GB, 400GB and 800GB 6G SSD SAS SFF Drive Models (MO0200FCTRN, MO0400FCTRP and MO0800FCTRQ)

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD4(4 Nov 2015)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 6.0
File name: cp028378.exe (2.6 MB)
This Windows Smart Component contains a firmware update for SFF hard drive models MO0200FCTRN (200GB 6G SSD SAS), MO0400FCTRP (400GB 6G SSD SAS) and MO0800FCTRQ (800GB 6G SSD SAS) in HP MSA 2040 Storage Arrays.

Prerequisites:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 2040 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 2040 Storage Arrays.


To ensure the integrity of your download, HPE recommends verifying your results with this MD5 Checksum value:

9bfb5061d3e9a0af699660ff105e54c1 cp028378.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Smart Component:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option:

  1.     Place the downloaded firmware package in a temporary directory.
  2.     Using Windows Explorer, navigate to the directory containing the download.
  3.     Double click the executable file.
  4.     Follow onscreen instructions.


CLI option:

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  •     ip_address is the management IP address of the array controller
  •     username is the username account with management rights
  •     password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  •     oa_address: set this variable for the IP address of array controller
  •     oa_username : set this variable for the username of array controller
  •     oa_password : set this variable for the password of that username

NOTE:

  • For details on supported command options, see the online help by executing the command CPxxxxxx.exe /h.

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 2040 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 2040 Storage Arrays.


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP MSA 2040 SAN Dual Controller SFF Storage
  • HP MSA 2040 SAS Dual Controller SFF Storage

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue is fixed in this firmware:

  • Fixed issue where the drive may not flush user data to media.

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 2040 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 2040 Storage Arrays.

Version:HPD4 (4 Nov 2015)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue is fixed in this firmware:

  • Fixed issue where the drive may not flush user data to media.

Type: Firmware - SAS Storage Disk
Version: HPD4(4 Nov 2015)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 6.0

Description

This Windows Smart Component contains a firmware update for SFF hard drive models MO0200FCTRN (200GB 6G SSD SAS), MO0400FCTRP (400GB 6G SSD SAS) and MO0800FCTRQ (800GB 6G SSD SAS) in HP MSA 2040 Storage Arrays.

Installation Instructions

Prerequisites:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 2040 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 2040 Storage Arrays.


To ensure the integrity of your download, HPE recommends verifying your results with this MD5 Checksum value:

9bfb5061d3e9a0af699660ff105e54c1 cp028378.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Smart Component:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option:

  1.     Place the downloaded firmware package in a temporary directory.
  2.     Using Windows Explorer, navigate to the directory containing the download.
  3.     Double click the executable file.
  4.     Follow onscreen instructions.


CLI option:

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  •     ip_address is the management IP address of the array controller
  •     username is the username account with management rights
  •     password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  •     oa_address: set this variable for the IP address of array controller
  •     oa_username : set this variable for the username of array controller
  •     oa_password : set this variable for the password of that username

NOTE:

  • For details on supported command options, see the online help by executing the command CPxxxxxx.exe /h.

Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 2040 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 2040 Storage Arrays.


Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP MSA 2040 SAN Dual Controller SFF Storage
  • HP MSA 2040 SAS Dual Controller SFF Storage

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue is fixed in this firmware:

  • Fixed issue where the drive may not flush user data to media.

Important

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 2040 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 2040 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 2040 Storage Arrays.

Revision History

Version:HPD4 (4 Nov 2015)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue is fixed in this firmware:

  • Fixed issue where the drive may not flush user data to media.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.