* RECOMMENDED * Online HDD/SDD Flash Component for Linux (x64) - VK003840GWSXL Drive
By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:
Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.
This x64 Smart Component provides firmware for the following drive model: VK003840GWSXL Drive
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
To ensure the integrity of your download, HPE recommends verifying your results with
the following SHA-256 Checksum values:
3102ef509417a4e3eed22010645c0b97147c30b79a5d27a9d6fbc031ca9e1b0c |
rpm/RPMS/x86_64/firmware-hdd-d1cf327bc4-HPG2-3.1.x86_64.rpm |
35272b707ce030e1a5db32ce15d47e501f04c69b30187be477f96185dee8269e |
rpm/RPMS/x86_64/firmware-hdd-d1cf327bc4-HPG2-3.1.x86_64.compsig |
Reboot Requirement: Reboot may be required after installation for updates to take effect and hardware stability to be maintained.
Installation:
To update firmware from Linux operating system on target server:
Updating firmware by installing the rpm:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.
- The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.
- To install firmware, you can execute ONE of the following commands:
- ./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)
- ./setup in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension.
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory.
- Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run ./setup to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.
To use Smart Update Manager from the Service Pack for ProLiant:
Offline:
- Place the Service Pack for ProLiant on a USB key using the USB Key Utility for Windows.
- Place the desired firmware to be updated in the directory, /packages on the USB key.
- Boot from the newly created Service Pack for Proliant USB key.
- Follow Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /packages.
- Run launch_sum.sh script which is found in the root of the ISO.
Follow the instructions on the screen.
End User License Agreements: HPE Software License Agreement v1
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
Notes:
Deliverable Name:
Online HDD/SDD Flash Component for Linux (x64) - VK003840GWSXL Drive
Release Version and/or Date:
HPG2
Last Recommended or Critical Version:
HPG2
Previous Version of Firmware:
NA
Firmware Dependency:
None
Enhancements/New Features:
Problems Fixed:
Known Issues:
None
Version:HPG2(D) (5 Oct 2020)
Enhancements
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
- Added support for RHEL 8.2
Version:HPG2(C) (20 Dec 2019)
Enhancements
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
Version:HPG2(B) (9 Sep 2019)
Fixes
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
- Fix to issue in bootloader download during power loss.
- Change IDF Word 106 report 4K TU for 4/8TB drives to align with Microsoft SQL requirement.
- Improvements to error exception.
- Improvements to Secure lock fix during multi-thread read tests with high freq. power cycling.
Enhancements
Version:HPG2 (19 Jul 2019)
Fixes
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Fix to issue in bootloader download during power loss.
- Change IDF Word 106 report 4K TU for 4/8TB drives to align with Microsoft SQL requirement.
- Improvements to error exception.
- Improvements to Secure lock fix during multi-thread read tests with high freq. power cycling.
Type: |
Firmware - SATA Storage Disk |
Version: |
HPG2(C)(20 Dec 2019) |
Operating System(s): |
Red Hat Enterprise Linux 6 Server (x86-64)
|
Red Hat Enterprise Linux 7 Server
|
Red Hat Enterprise Linux 8 Server
|
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
|
SUSE Linux Enterprise Server 12
|
SUSE Linux Enterprise Server 15
|
|
Description
This x64 Smart Component provides firmware for the following drive model: VK003840GWSXL Drive
Enhancements
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
Installation Instructions
To ensure the integrity of your download, HPE recommends verifying your results with
the following SHA-256 Checksum values:
3102ef509417a4e3eed22010645c0b97147c30b79a5d27a9d6fbc031ca9e1b0c |
rpm/RPMS/x86_64/firmware-hdd-d1cf327bc4-HPG2-3.1.x86_64.rpm |
35272b707ce030e1a5db32ce15d47e501f04c69b30187be477f96185dee8269e |
rpm/RPMS/x86_64/firmware-hdd-d1cf327bc4-HPG2-3.1.x86_64.compsig |
Reboot Requirement: Reboot may be required after installation for updates to take effect and hardware stability to be maintained.
Installation:
To update firmware from Linux operating system on target server:
Updating firmware by installing the rpm:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.
- The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.
- To install firmware, you can execute ONE of the following commands:
- ./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)
- ./setup in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension.
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory.
- Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run ./setup to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.
To use Smart Update Manager from the Service Pack for ProLiant:
Offline:
- Place the Service Pack for ProLiant on a USB key using the USB Key Utility for Windows.
- Place the desired firmware to be updated in the directory, /packages on the USB key.
- Boot from the newly created Service Pack for Proliant USB key.
- Follow Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /packages.
- Run launch_sum.sh script which is found in the root of the ISO.
Follow the instructions on the screen.
Release Notes
End User License Agreements: HPE Software License Agreement v1
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
Notes:
Deliverable Name:
Online HDD/SDD Flash Component for Linux (x64) - VK003840GWSXL Drive
Release Version and/or Date:
HPG2
Last Recommended or Critical Version:
HPG2
Previous Version of Firmware:
NA
Firmware Dependency:
None
Enhancements/New Features:
Problems Fixed:
Known Issues:
None
Revision History
Version:HPG2(D) (5 Oct 2020)
Enhancements
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
- Added support for RHEL 8.2
Version:HPG2(C) (20 Dec 2019)
Enhancements
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
Version:HPG2(B) (9 Sep 2019)
Fixes
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode or Host Bus Adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Customers who already installed latest firmware version do not need to update to sub version like (B) (C) (D) etc..
- Fix to issue in bootloader download during power loss.
- Change IDF Word 106 report 4K TU for 4/8TB drives to align with Microsoft SQL requirement.
- Improvements to error exception.
- Improvements to Secure lock fix during multi-thread read tests with high freq. power cycling.
Enhancements
Version:HPG2 (19 Jul 2019)
Fixes
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
- Online firmware flashing of drives attached to a Smart Array controller running in Zero Memory (ZM) mode is NOT supported. Only offline firmware flashing of drives is supported for these configurations.
- Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager.
- Fix to issue in bootloader download during power loss.
- Change IDF Word 106 report 4K TU for 4/8TB drives to align with Microsoft SQL requirement.
- Improvements to error exception.
- Improvements to Secure lock fix during multi-thread read tests with high freq. power cycling.
|
|