Printable version

Drivers & software

* RECOMMENDED * Emulex(BRCM) Fibre Channel over Ethernet driver for VMware vSphere 6.7

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Software - Storage Fibre Channel and Fibre Channel Over Ethernet
Version: 2019.03.03(25 Jul 2019)
Operating System(s): VMware vSphere 6.7
Multi-part download
File name: cp040416.compsig (2.0 KB)
File name: cp040416.zip (1.1 MB)
VMware vSphere 6.7 Fibre Channel over Ethernet Driver kit for HPE Emulex(BRCM) Converged Network Adapters

.Updated to Driver version 12.0.1216.4

Prerequisites:

Please consult SPOCK for a list of supported configurations available at the following link:

http://www.hpe.com/storage/spock/

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change. 

To obtain the guide:

  1.  Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

 #esxcli software vib remove lpfc


To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

9712c3d5c75daf20560bb9b49f6f4ab1fa37b84a51dd6b8cf51adf35b7a90bca cp040416.zip
d5ea031931cbce8a639b488ef785be07d9795838c05c5e58e063ca30c2e982a4 cp040416.compsig

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

 To use Smart Update Manager from the Service Pack for ProLiant:

Remote Online, if the component is supported by SUM but is not yet part of an SPP:

  • Download the appropriate Service Pack for ProLiant
  • Add the component to the Service Pack for ProLiant
  • Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated
  • Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux
  • Add the ESXi host to be updated as a remote target/node
  • Enter the IP or DNS address of the ESXi host to be updated
  • Enter the ESXi host credentials (root or administrator username and password)
  • For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.
  • Follow Smart Update Manager Steps and complete the firmware update.
  • Refer to the Service Pack for ProLiant Documentation for detailed instructions at: www.hpe.com/servers/spp/download

To update the driver using VMware tools:

  • Unzip this HPE component to extract the driver offline bundle
  • Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.
  • Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands

 

 


End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

This component is intended to be used by HPE applications.  It is a zip that contains the same driver deliverable available from the vmware.com and the HPE vibsdepot.hpe.com webpages, plus an HPE specific CPXXXX.xml file.

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change. 

To obtain the guide:

  1.  Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

 #esxcli software vib remove lpfc


Supported Devices and Features:

This component is supported on following Emulex Converged Network Adapters:

XE100 Series:

  • HP StoreFabric CN1200E Dual Port Converged Network Adapter
  • HP FlexFabric 20Gb 2-port 650FLB Adapter
  • HP FlexFabric 20Gb 2-port 650M Adapter
  • HPE StoreFabric CN1200E-T Adapter

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixed the following:

  • Purple Screen of Death(PSOD) may occur with "Wake NOT Set" message on HPE ProLiant Blade Servers configured with HPE FlexFabric 20Gb 2-port 650FLB Adapter

For more details please go through the document titled " HPE Network Adapters - HPE Servers Running VMware ESXi 6.0 / 6.5 / 6.7 And Configured With an HPE FlexFabric 20Gb 2-port 650FLB Adapter, May Log "Wake NOT Set" Messages In The Vmkernel Log And Eventually a PSOD May Occur" at the following link:

https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00091760en_us

This component is intended to be used by HPE applications.  It is a zip that contains the same driver deliverable available from the vmware.com and the HPE vibsdepot.hpe.com webpages, plus an HPE specific CPXXXX.xml file.

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change. 

To obtain the guide:

  1.  Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

 #esxcli software vib remove lpfc

Version:2019.12.01 (24 Dec 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixed the following:

  • Purple Screen of Death(PSOD) at random intervals on HPE FlexFabric 20Gb 2-port 650FLB Adapter
  • Link down after 1000 times port down and up iterations on switch.
  • Detaching is not completing because lpfc_do_work_event can't exit.
  • Slab memory use after free causing memory leak.
  • Small Computer Sytem Interface(SCSI) command is used after done call.
  • Target reset does not report original status
Enhancements

Updated to Driver version 12.0.1278.0


Version:2019.03.03 (25 Jul 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixed the following:

  • Purple Screen of Death(PSOD) may occur with "Wake NOT Set" message on HPE ProLiant Blade Servers configured with HPE FlexFabric 20Gb 2-port 650FLB Adapter

For more details please go through the document titled " HPE Network Adapters - HPE Servers Running VMware ESXi 6.0 / 6.5 / 6.7 And Configured With an HPE FlexFabric 20Gb 2-port 650FLB Adapter, May Log "Wake NOT Set" Messages In The Vmkernel Log And Eventually a PSOD May Occur" at the following link:

https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00091760en_us

Enhancements

.Updated to Driver version 12.0.1216.4


Version:2019.03.01 (2 Apr 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixed the following:

  • Added workaround to reduce the race probability in Input Output Device Management (IODM).
  • VMWare vSphere 6.7 Update 1 becomes unresponsive to commands like “esxtop” and “esxcli storage core adapter list” after vmkfstool bus and target reset.
  • Fixed Purple Screen of Death (PSOD) Triggered by assert that when destroying a Slab and there was still one object not released.
Enhancements

Added support for VMWare vSphere 6.7 Update 1.

Updated to Driver version 12.0.1211.0


Version:2018.11.01 (27 Nov 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Updated to Driver version 12.0.1115.0


Version:2018.06.01 (27 Jun 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Updated to Driver version 12.0.1115.0


Version:2018.02.01 (19 Apr 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release supporting VMware vSphere 6.7

Driver version 12.0.1113.0


Type: Software - Storage Fibre Channel and Fibre Channel Over Ethernet
Version: 2019.03.03(25 Jul 2019)
Operating System(s):
VMware vSphere 6.7

Description

VMware vSphere 6.7 Fibre Channel over Ethernet Driver kit for HPE Emulex(BRCM) Converged Network Adapters

Enhancements

.Updated to Driver version 12.0.1216.4

Installation Instructions

Prerequisites:

Please consult SPOCK for a list of supported configurations available at the following link:

http://www.hpe.com/storage/spock/

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change. 

To obtain the guide:

  1.  Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

 #esxcli software vib remove lpfc


To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

9712c3d5c75daf20560bb9b49f6f4ab1fa37b84a51dd6b8cf51adf35b7a90bca cp040416.zip
d5ea031931cbce8a639b488ef785be07d9795838c05c5e58e063ca30c2e982a4 cp040416.compsig

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.


Installation:

 To use Smart Update Manager from the Service Pack for ProLiant:

Remote Online, if the component is supported by SUM but is not yet part of an SPP:

  • Download the appropriate Service Pack for ProLiant
  • Add the component to the Service Pack for ProLiant
  • Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated
  • Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux
  • Add the ESXi host to be updated as a remote target/node
  • Enter the IP or DNS address of the ESXi host to be updated
  • Enter the ESXi host credentials (root or administrator username and password)
  • For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.
  • Follow Smart Update Manager Steps and complete the firmware update.
  • Refer to the Service Pack for ProLiant Documentation for detailed instructions at: www.hpe.com/servers/spp/download

To update the driver using VMware tools:

  • Unzip this HPE component to extract the driver offline bundle
  • Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.
  • Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands

 

 


Release Notes

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

This component is intended to be used by HPE applications.  It is a zip that contains the same driver deliverable available from the vmware.com and the HPE vibsdepot.hpe.com webpages, plus an HPE specific CPXXXX.xml file.

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change. 

To obtain the guide:

  1.  Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

 #esxcli software vib remove lpfc


Supported Devices and Features:

This component is supported on following Emulex Converged Network Adapters:

XE100 Series:

  • HP StoreFabric CN1200E Dual Port Converged Network Adapter
  • HP FlexFabric 20Gb 2-port 650FLB Adapter
  • HP FlexFabric 20Gb 2-port 650M Adapter
  • HPE StoreFabric CN1200E-T Adapter

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixed the following:

  • Purple Screen of Death(PSOD) may occur with "Wake NOT Set" message on HPE ProLiant Blade Servers configured with HPE FlexFabric 20Gb 2-port 650FLB Adapter

For more details please go through the document titled " HPE Network Adapters - HPE Servers Running VMware ESXi 6.0 / 6.5 / 6.7 And Configured With an HPE FlexFabric 20Gb 2-port 650FLB Adapter, May Log "Wake NOT Set" Messages In The Vmkernel Log And Eventually a PSOD May Occur" at the following link:

https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00091760en_us

Important

This component is intended to be used by HPE applications.  It is a zip that contains the same driver deliverable available from the vmware.com and the HPE vibsdepot.hpe.com webpages, plus an HPE specific CPXXXX.xml file.

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change. 

To obtain the guide:

  1.  Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

 #esxcli software vib remove lpfc

Revision History

Version:2019.12.01 (24 Dec 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixed the following:

  • Purple Screen of Death(PSOD) at random intervals on HPE FlexFabric 20Gb 2-port 650FLB Adapter
  • Link down after 1000 times port down and up iterations on switch.
  • Detaching is not completing because lpfc_do_work_event can't exit.
  • Slab memory use after free causing memory leak.
  • Small Computer Sytem Interface(SCSI) command is used after done call.
  • Target reset does not report original status
Enhancements

Updated to Driver version 12.0.1278.0


Version:2019.03.03 (25 Jul 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixed the following:

  • Purple Screen of Death(PSOD) may occur with "Wake NOT Set" message on HPE ProLiant Blade Servers configured with HPE FlexFabric 20Gb 2-port 650FLB Adapter

For more details please go through the document titled " HPE Network Adapters - HPE Servers Running VMware ESXi 6.0 / 6.5 / 6.7 And Configured With an HPE FlexFabric 20Gb 2-port 650FLB Adapter, May Log "Wake NOT Set" Messages In The Vmkernel Log And Eventually a PSOD May Occur" at the following link:

https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00091760en_us

Enhancements

.Updated to Driver version 12.0.1216.4


Version:2019.03.01 (2 Apr 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Fixed the following:

  • Added workaround to reduce the race probability in Input Output Device Management (IODM).
  • VMWare vSphere 6.7 Update 1 becomes unresponsive to commands like “esxtop” and “esxcli storage core adapter list” after vmkfstool bus and target reset.
  • Fixed Purple Screen of Death (PSOD) Triggered by assert that when destroying a Slab and there was still one object not released.
Enhancements

Added support for VMWare vSphere 6.7 Update 1.

Updated to Driver version 12.0.1211.0


Version:2018.11.01 (27 Nov 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Updated to Driver version 12.0.1115.0


Version:2018.06.01 (27 Jun 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Updated to Driver version 12.0.1115.0


Version:2018.02.01 (19 Apr 2018)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release supporting VMware vSphere 6.7

Driver version 12.0.1113.0


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.