Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Linux - HP MSA 1040/2040 and P2000 G3 1TB 6G SAS 7.2K rpm SFF Drive Model (MM1000FECVH)

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD2(13 Jan 2016)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0
File name: CP028905.scexe (6.8 MB)
This Linux Smart Component contains a firmware update for SFF hard drive model MM1000FECVH(1TB 6G SAS 7.2K) in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Enhancements/New Features:

  • Added servo improvements which reduce power consumption.

Prerequisites:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: FTP and HTTPS/Telnet services must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed.


To ensure the integrity of your download, HPE recommends verifying your results with this MD5 Checksum value:

6b0217670cd25d363baf28767f1f0efd CP028905.scexe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Smart Component:

  1. Place the downloaded firmware package in a temporary directory.
  2. Open a Linux command console.
  3. From the directory containing the downloaded file, enable execute access to this module by entering chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
  4. Execute the Smart Component by entering a command similar to the following: ./CPxxxxxx.scexe --target <ip_address> --user <username> --passwd <password>
  5. Follow onscreen instructions.

NOTE:

  • Use the -e / --reflash or -f / --force option when flashing a device, even if it is up to date.
  • Use the -g / --downgrade option when downgrading.
  • For details on supported command options, see the online help by executing the command ./CPxxxxxx.scexe or ./CPxxxxxx.scexe -h / --help.
  • If the user name or password contains an exclamation mark (!), enclose the string in single quotes or enter a backslash (\) before the exclamation point. For example, '!manage' or \!manage

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: FTP and HTTPS/Telnet services must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP MSA 2040 SAN SFF Storage
  • HP MSA 2040 SAS SFF Storage
  • HP MSA 1040 SAN SFF Storage
  • HP MSA 1040 SAS SFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 SAS MSA Dual Controller SFF Array System
  • HP P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Drive self-test did not complete within the specified time.
  • During a fully cached workload, SMART would report incorrect temperature values.
  • The component would fail to flash drive firmware on a server with a Trusted Platform Module (TPM) enabled when using the /tpmbypass switch.

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: FTP and HTTPS/Telnet services must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed.

Version:HPD2 (13 Jan 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Drive self-test did not complete within the specified time.
  • During a fully cached workload, SMART would report incorrect temperature values.
  • The component would fail to flash drive firmware on a server with a Trusted Platform Module (TPM) enabled when using the /tpmbypass switch.
Enhancements

Enhancements/New Features:

  • Added servo improvements which reduce power consumption.

Version:HPD1 (2 Dec 2015)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue is fixed in this version of firmware:

  • This firmware resolved a potential multiport system failover condition where the drive might not be recognized, due to the drive responding too slowly to a link reset on port A if port B was unavailable. 
  • This firmware also fixed possible aborted command errors due to incorrect overlapped command tag checking being performed.

Type: Firmware - SAS Storage Disk
Version: HPD2(13 Jan 2016)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0

Description

This Linux Smart Component contains a firmware update for SFF hard drive model MM1000FECVH(1TB 6G SAS 7.2K) in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Enhancements

Enhancements/New Features:

  • Added servo improvements which reduce power consumption.

Installation Instructions

Prerequisites:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: FTP and HTTPS/Telnet services must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed.


To ensure the integrity of your download, HPE recommends verifying your results with this MD5 Checksum value:

6b0217670cd25d363baf28767f1f0efd CP028905.scexe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Smart Component:

  1. Place the downloaded firmware package in a temporary directory.
  2. Open a Linux command console.
  3. From the directory containing the downloaded file, enable execute access to this module by entering chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
  4. Execute the Smart Component by entering a command similar to the following: ./CPxxxxxx.scexe --target <ip_address> --user <username> --passwd <password>
  5. Follow onscreen instructions.

NOTE:

  • Use the -e / --reflash or -f / --force option when flashing a device, even if it is up to date.
  • Use the -g / --downgrade option when downgrading.
  • For details on supported command options, see the online help by executing the command ./CPxxxxxx.scexe or ./CPxxxxxx.scexe -h / --help.
  • If the user name or password contains an exclamation mark (!), enclose the string in single quotes or enter a backslash (\) before the exclamation point. For example, '!manage' or \!manage

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: FTP and HTTPS/Telnet services must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP MSA 2040 SAN SFF Storage
  • HP MSA 2040 SAS SFF Storage
  • HP MSA 1040 SAN SFF Storage
  • HP MSA 1040 SAS SFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 SAS MSA Dual Controller SFF Array System
  • HP P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Drive self-test did not complete within the specified time.
  • During a fully cached workload, SMART would report incorrect temperature values.
  • The component would fail to flash drive firmware on a server with a Trusted Platform Module (TPM) enabled when using the /tpmbypass switch.

Important

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: FTP and HTTPS/Telnet services must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed.

Revision History

Version:HPD2 (13 Jan 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Drive self-test did not complete within the specified time.
  • During a fully cached workload, SMART would report incorrect temperature values.
  • The component would fail to flash drive firmware on a server with a Trusted Platform Module (TPM) enabled when using the /tpmbypass switch.
Enhancements

Enhancements/New Features:

  • Added servo improvements which reduce power consumption.

Version:HPD1 (2 Dec 2015)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issue is fixed in this version of firmware:

  • This firmware resolved a potential multiport system failover condition where the drive might not be recognized, due to the drive responding too slowly to a link reset on port A if port B was unavailable. 
  • This firmware also fixed possible aborted command errors due to incorrect overlapped command tag checking being performed.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.