Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Windows - HP StorageWorks P2000/MSA2000 500GB 6G SAS 7.2K rpm SFF Hard Drive (MM0500FAMYT)

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD4(4 May 2011)
Operating System(s):
Microsoft Windows Server 2003 | View all
File name: cp014865.exe (2.7 MB)
This Windows Smart Component contains a firmware update for the hard drive model MM0500FAMYT (500GB 7K SAS 6G) in HP StorageWorks P2000 G3 MSA and MSA2000 G2 configurations.

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

bacee6e71606aec5bdccf3f9b91d665d cp014865.exe

Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of array controller


End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


Notes:

Deliverable Name:
     Firmware Flash Component for Windows - HP StorageWorks P2000/MSA2000 500GB 6G SAS 7.2K rpm SFF Hard Drive (MM0500FAMYT)

Release Version and/or Date:
      HPD4

Last Recommended or Critical Version:
      HPD4

Previous Version of Firmware:
      HPD3

Enhancements/New Features:
     None

Problems Fixed:

  • Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.

Known Issues:
     None

Failure Considerations:

  1. Single ported drive will not be flashed if the owner controller of that drive is not accessible through network.
  2. Drives will not be flashed if the drive is in a virtual disk which is being initialized, expanded, reconstructed, verified, or scrubbed.
  3. Flash operation on any pending disks will be aborted if the currently flashed drive is in LEFTOVR state or the virtual disk containing this disk is found to be in offline or critical state. If this does occur, the vdisk can be restored to online status by changing the drive status from leftover to available and then adding the drive to the vdisk as a spare. If a global spare drive was available, it will have been used to restore the vdisk to online status.

Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any P2000 G3 or MSA2000 array controller enclosure.


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.

Version:HPD4 (A) (6 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware HPD4(A) is not necessary if HDDs are currently running HPD4 firmware.
Only the Smart Component package digital certificate has been updated for version HPD4(A)


Following issue was fixed in HPD4: 

  • Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.
Enhancements

Following enhancement is added in HPD4: 

  • Added Support for MSA 1040/2040 Arrays.

Version:HPD4 (4 May 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.


Version:HPD3 (13 Jul 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products


Type: Firmware - SAS Storage Disk
Version: HPD4(4 May 2011)
Operating System(s):
Microsoft Windows Server 2003
Microsoft Windows Server 2003 64-Bit Edition
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 Itanium
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64

Description

This Windows Smart Component contains a firmware update for the hard drive model MM0500FAMYT (500GB 7K SAS 6G) in HP StorageWorks P2000 G3 MSA and MSA2000 G2 configurations.

Installation Instructions

Prerequisites:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

bacee6e71606aec5bdccf3f9b91d665d cp014865.exe

Installation:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option

  1. Place the downloaded firmware package in a temporary directory.

  2. Using Windows Explorer, navigate to the directory containing the download.

  3. Double click the executable file.

  4. Follow onscreen instructions.


CLI option

Execute the Smart Component by entering the following command: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s

where:

  • ip_address is the management IP address of the array controller

  • username is the username account with management rights

  • password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  • oa_address: set this variable for the IP address of array controller

  • oa_username : set this variable for the username of array controller

  • oa_password : set this variable for the password of array controller


Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Important:

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.


Notes:

Deliverable Name:
     Firmware Flash Component for Windows - HP StorageWorks P2000/MSA2000 500GB 6G SAS 7.2K rpm SFF Hard Drive (MM0500FAMYT)

Release Version and/or Date:
      HPD4

Last Recommended or Critical Version:
      HPD4

Previous Version of Firmware:
      HPD3

Enhancements/New Features:
     None

Problems Fixed:

  • Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.

Known Issues:
     None

Failure Considerations:

  1. Single ported drive will not be flashed if the owner controller of that drive is not accessible through network.
  2. Drives will not be flashed if the drive is in a virtual disk which is being initialized, expanded, reconstructed, verified, or scrubbed.
  3. Flash operation on any pending disks will be aborted if the currently flashed drive is in LEFTOVR state or the virtual disk containing this disk is found to be in offline or critical state. If this does occur, the vdisk can be restored to online status by changing the drive status from leftover to available and then adding the drive to the vdisk as a spare. If a global spare drive was available, it will have been used to restore the vdisk to online status.

Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any P2000 G3 or MSA2000 array controller enclosure.


Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.

Important

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the P2000/MSA2000 storage system

NOTE: Disk drive upgrades on the HP StorageWorks P2000/MSA2000 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP StorageWorks 2000 Family Modular Storage Array reference guide.

IMPORTANT: Please refer to the release notes for special considerations regarding the pre-install conditions for flashing hard drives in P2000/MSA2000 configurations.

Revision History

Version:HPD4 (A) (6 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.

Upgrade to HDD firmware HPD4(A) is not necessary if HDDs are currently running HPD4 firmware.
Only the Smart Component package digital certificate has been updated for version HPD4(A)


Following issue was fixed in HPD4: 

  • Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.
Enhancements

Following enhancement is added in HPD4: 

  • Added Support for MSA 1040/2040 Arrays.

Version:HPD4 (4 May 2011)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Addresses an issue that can result in premature failure due to the drive experiencing a ‘not ready' condition.


Version:HPD3 (13 Jul 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.