Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Linux - HPE MSA 1040/2040/1050/2050 Drive Models EH000300JWHPL, EH000600JWHPN and EH000900JWHPP

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD3(28 Mar 2019)
Operating System(s):
Microsoft Windows Server 2012 | View all
File name: CP038956.scexe (10 MB)
This Linux Smart Component contains a firmware update for 300GB/600GB/900GB 12G SAS 15K drive models EH000300JWHPL, EH000600JWHPN, EH000900JWHPP in HPE MSA 1040/2040/1050/2050 Storage Array.

Following enhancement was added to the Flash Engine, used with this version of Smart Component:

  • Enables support to LDAP user authentication to HPE MSA 1050/2050  Storage Array.

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

71eeba53a45f686a89b5a0a70fa91fd65cb4596e45daba43d209358724e133a0 CP038956.scexe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

NOTE: When you download this module from the HPE.com web site, you cannot double click on the link. You will need to right click the link and select "save as" or similar option. This module is a SCEXE file. It is a self extracting executable module. This module only operates from the Linux command line.

Installation instructions using Smart Component:

  1. Place the downloaded firmware package in a temporary directory.
  2. Open a Linux command console.
  3. From the directory containing the downloaded file, enable execute access to this module by entering chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
  4. Execute the Smart Component by entering a command similar to the following: ./CPxxxxxx.scexe --target <ip_address> --user <username> --passwd <password>
  5. Follow onscreen instructions.
  6. Wait for the installation to complete. Upon completion, a confirmation message is displayed.

NOTE:

  • Stop all I/O to array before starting the firmware update.
  • Use the -e / --reflash or -f / --force option when flashing a device, even if it is up to date.
  • Use the -g / --downgrade option when downgrading.
  • For details on supported command options, see the online help by executing the command ./CPxxxxxx.scexe or ./CPxxxxxx.scexe -h / --help.
  • If the user name or password contains a special character, enclose the string in single quotes or enter a backslash (\) before the special character. For example, '!manage' or \!manage

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE MSA 1040 SAN LFF Storage
  • HPE MSA 1040 SAN SFF Storage
  • HPE MSA 1040 SAS LFF Storage
  • HPE MSA 1040 SAS SFF Storage
  • HPE MSA 2040 SAN LFF Storage
  • HPE MSA 2040 SAN SFF Storage
  • HPE MSA 2040 SAS LFF Storage
  • HPE MSA 2040 SAS SFF Storage
  • HPE MSA 2042 SAN LFF Storage
  • HPE MSA 2042 SAN SFF Storage
  • HPE MSA 2042 SAS LFF Storage
  • HPE MSA 2042 SAS SFF Storage
  • HPE MSA 1050 SAN LFF Storage
  • HPE MSA 1050 SAN SFF Storage
  • HPE MSA 1050 SAS LFF Storage
  • HPE MSA 1050 SAS SFF Storage
  • HPE MSA 2050 SAN LFF Storage  
  • HPE MSA 2050 SAN SFF Storage
  • HPE MSA 2050 SAS LFF Storage
  • HPE MSA 2050 SAS SFF Storage
  • HPE MSA 2052 SAN LFF Storage  
  • HPE MSA 2052 SAN SFF Storage
  • HPE MSA 2052 SAS LFF Storage
  • HPE MSA 2052 SAS SFF Storage
  • HPE MSA 2040 LFF Disk Enclosure
  • HPE MSA 2050 LFF Disk Enclosure
  • HPE MSA 2050 SFF Disk Enclosure

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this release of firmware:

  • Removes a vendor unique sense code that the controller does not handle properly.
  • Includes changes to eliminate the cause of a potential hang condition.
  • Changes some settings to comply with Microsoft Storage Spaces Certification requirements.

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.

Version:HPD3 (28 Mar 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this release of firmware:

  • Removes a vendor unique sense code that the controller does not handle properly.
  • Includes changes to eliminate the cause of a potential hang condition.
  • Changes some settings to comply with Microsoft Storage Spaces Certification requirements.
Enhancements

Following enhancement was added to the Flash Engine, used with this version of Smart Component:

  • Enables support to LDAP user authentication to HPE MSA 1050/2050  Storage Array.

Type: Firmware - SAS Storage Disk
Version: HPD3(28 Mar 2019)
Operating System(s):
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
SUSE Linux Enterprise Server 15
VMware vSphere 5.5
VMware vSphere 6.0
VMware vSphere 6.5

Description

This Linux Smart Component contains a firmware update for 300GB/600GB/900GB 12G SAS 15K drive models EH000300JWHPL, EH000600JWHPN, EH000900JWHPP in HPE MSA 1040/2040/1050/2050 Storage Array.

Enhancements

Following enhancement was added to the Flash Engine, used with this version of Smart Component:

  • Enables support to LDAP user authentication to HPE MSA 1050/2050  Storage Array.

Installation Instructions

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

71eeba53a45f686a89b5a0a70fa91fd65cb4596e45daba43d209358724e133a0 CP038956.scexe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

NOTE: When you download this module from the HPE.com web site, you cannot double click on the link. You will need to right click the link and select "save as" or similar option. This module is a SCEXE file. It is a self extracting executable module. This module only operates from the Linux command line.

Installation instructions using Smart Component:

  1. Place the downloaded firmware package in a temporary directory.
  2. Open a Linux command console.
  3. From the directory containing the downloaded file, enable execute access to this module by entering chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
  4. Execute the Smart Component by entering a command similar to the following: ./CPxxxxxx.scexe --target <ip_address> --user <username> --passwd <password>
  5. Follow onscreen instructions.
  6. Wait for the installation to complete. Upon completion, a confirmation message is displayed.

NOTE:

  • Stop all I/O to array before starting the firmware update.
  • Use the -e / --reflash or -f / --force option when flashing a device, even if it is up to date.
  • Use the -g / --downgrade option when downgrading.
  • For details on supported command options, see the online help by executing the command ./CPxxxxxx.scexe or ./CPxxxxxx.scexe -h / --help.
  • If the user name or password contains a special character, enclose the string in single quotes or enter a backslash (\) before the special character. For example, '!manage' or \!manage

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE MSA 1040 SAN LFF Storage
  • HPE MSA 1040 SAN SFF Storage
  • HPE MSA 1040 SAS LFF Storage
  • HPE MSA 1040 SAS SFF Storage
  • HPE MSA 2040 SAN LFF Storage
  • HPE MSA 2040 SAN SFF Storage
  • HPE MSA 2040 SAS LFF Storage
  • HPE MSA 2040 SAS SFF Storage
  • HPE MSA 2042 SAN LFF Storage
  • HPE MSA 2042 SAN SFF Storage
  • HPE MSA 2042 SAS LFF Storage
  • HPE MSA 2042 SAS SFF Storage
  • HPE MSA 1050 SAN LFF Storage
  • HPE MSA 1050 SAN SFF Storage
  • HPE MSA 1050 SAS LFF Storage
  • HPE MSA 1050 SAS SFF Storage
  • HPE MSA 2050 SAN LFF Storage  
  • HPE MSA 2050 SAN SFF Storage
  • HPE MSA 2050 SAS LFF Storage
  • HPE MSA 2050 SAS SFF Storage
  • HPE MSA 2052 SAN LFF Storage  
  • HPE MSA 2052 SAN SFF Storage
  • HPE MSA 2052 SAS LFF Storage
  • HPE MSA 2052 SAS SFF Storage
  • HPE MSA 2040 LFF Disk Enclosure
  • HPE MSA 2050 LFF Disk Enclosure
  • HPE MSA 2050 SFF Disk Enclosure

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this release of firmware:

  • Removes a vendor unique sense code that the controller does not handle properly.
  • Includes changes to eliminate the cause of a potential hang condition.
  • Changes some settings to comply with Microsoft Storage Spaces Certification requirements.

Important

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.

Revision History

Version:HPD3 (28 Mar 2019)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this release of firmware:

  • Removes a vendor unique sense code that the controller does not handle properly.
  • Includes changes to eliminate the cause of a potential hang condition.
  • Changes some settings to comply with Microsoft Storage Spaces Certification requirements.
Enhancements

Following enhancement was added to the Flash Engine, used with this version of Smart Component:

  • Enables support to LDAP user authentication to HPE MSA 1050/2050  Storage Array.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.