Type: |
Driver - Storage |
Version: |
6.16.0.64(23 Sep 2016) |
Operating System(s): |
Microsoft Windows Server 2008 R2
|
Microsoft Windows Server 2008 x64
|
Microsoft Windows Small Business Server 2011 Standard and Essentials
|
|
Description
REMOVED: Hpsa driver version 6.16.0.64 is NO LONGER AVAILABLE for download. Click the “Obtain software” link to open the HPE SC web page for the replacement version 6.16.0.64 (A). This driver provides Microsoft Windows Server 2008/2008 R2 64-bit support for: HPE Dynamic Smart Array B320i Controller. HPE Dynamic Smart Array B120i Controller.
Installation Instructions
To ensure the integrity of your download, HPE recommends verifying your results with
this SHA-256 Checksum value:
add3d5fa552df101ed704c1edb73bfa2ffcdf13642b00e3714c53a336ee37775 |
cp029890.exe |
Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.
Installation:
Place the Smart Component in a temporary directory, then double-click it to run.
Select "Install" to start extracting to a temporary location on the hard drive.
Click the "Install" button to perform the driver installation.
Release Notes
Fixes
Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.
REMOVED: Hpsa driver version 6.16.0.64 is NO LONGER AVAILABLE for download due to incorrect reboot instructions. Click the “Obtain software” link to open the HPE Support Center web page for the replacement version 6.16.0.64 (A).
Fixes included in version 6.16.0.64:
- Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)
Revision History
Version:6.16.0.64(A) (11 Aug 2017)
Fixes
Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.
Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)
Version:6.16.0.64 (23 Sep 2016)
Fixes
Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.
REMOVED: Hpsa driver version 6.16.0.64 is NO LONGER AVAILABLE for download due to incorrect reboot instructions. Click the “Obtain software” link to open the HPE Support Center web page for the replacement version 6.16.0.64 (A).
Fixes included in version 6.16.0.64:
- Fixes a BSOD issue that allows the HPE Dynamic Smart Array B320i/B120i Controller to run in a system with higher than 128 CPU (cores)
Version:6.14.0.64 (1 Apr 2016)
Fixes
Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.
The following issue is now resolved:
Intermittent blue screen 0x133 (DPS_WATCHDOG_VIOLATION) error would display and the system would stop responding. This error was caused by a race condition that was exposed under particular IO patterns for controllers with write cache enabled.
Version:6.12.0.64 (30 Mar 2015)
Fixes
Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.
-
Fixes issue with SCSI Verify that can cause bug check.
-
Fixes issue where newer, larger drives may not show up during hot add.
-
Fixes potential data mismatch to RAID5 volumes when read cache is enabled and physical drive fails.
Version:6.10.0.64 (13 Mar 2014)
Fixes
Upgrade Requirement:
Critical - HP requires users update to this version immediately.
Fix for CA referenced below titled “SPP HOT FIX - HP ProLiant Servers: HP Dynamic Smart Array B120i/B320i Controllers - DRIVER UPGRADE REQUIRED to Ensure That a Drive Array Rebuild Does Not Target an Incorrect Drive and Cause Incorrect Data to Be Written to the Drive”
http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04141183
Version:6.8.0.64 (10 Jan 2014)
Fixes
Upgrade Requirement:
Critical - HPE requires users update to this version immediately.
-
For systems with a FBWC and HP Dynamic Smart Array B120i/B320i controllers, fixed an issue involving crash dump and cache flush. In the case where a server failure occurs, and a crash dump is generated, in some cases the FBWC was not flushing before the crash dump is written to the disk. Please find customer advisory at http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04045904
Enhancements
-
New enhancements for SCSI Verify commands.
Version:6.6.2.64 (10 Sep 2013)
Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
New support for the following servers
-
HP ProLiant DL320e Gen8 v2 Server
-
HP ProLiant ML310e Gen8 v2 Server
-
HP ProLiant MicroServer Gen8
-
HP ProLiant SL210t Gen8 Server
Version:6.6.0.64 (19 Feb 2013)
Fixes
Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.
-
Resolved intermittent issues seen while burning to optical devices connected to HP Dynamic Smart Array B120i
Version:6.4.0.64 (29 Jun 2012)
Fixes
Upgrade Requirement:
Critical - HPE requires users update to this version immediately.
Enhancements
Reduced the driver shutdown time.
Version:6.2.0.64 (4 Jun 2012)
Enhancements
Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Initial Release.