Advisory: HP Smart Array Gen9 Controllers - An HP Smart Array Gen9 Controller Stops Responding During Power-On Self-Test (POST) When Connected to a Modular Smart Array 2040 Presenting More Than 64 LUNs

SUPPORT COMMUNICATION - CUSTOMER ADVISORY

Document ID: c04623059

Version: REQUIRED FIELD INADVERTENTLY LEFT BLANK

Advisory: HP Smart Array Gen9 Controllers - An HP Smart Array Gen9 Controller Stops Responding During Power-On Self-Test (POST) When Connected to a Modular Smart Array 2040 Presenting More Than 64 LUNs
NOTICE: The information in this document, including products and software versions, is current as of the Release Date. This document is subject to change without notice.

Release Date: 2015-03-31

Last Updated: 2016-01-11


DESCRIPTION

If any HP Smart Array Gen9 controller is connected to an HP StorageWorks Modular Smart Array 2040 (MSA2040) shared storage box, and more than 64 LUNs are presented from the MSA2040, the Smart Array Gen9 controller will stop responding during Power-On Self-Test (POST) with a General Protection Exception, x64 Exception Type 0D error.

SCOPE

Any ProLiant Gen9 server configured with any of the following running Smart Array Controller Firmware Version 2.10 or 2.12:

  • HP Smart HBA H240
  • HP Smart HBA H240ar
  • HP Smart HBA H241
  • HP Smart HBA H244br
  • HP Smart Array P246br
  • HP Smart Array P244br Controller
  • HP Smart Array P440 Controller
  • HP Smart Array P440ar Controller
  • HP Smart Array P441 Controller
  • HP Smart Array P841 Controller
  • HP Smart Array P840 Controller
  • HP Smart Array P741m Controller

Note: Smart Array Controller Firmware Version 1.34 is not affected by this issue.

RESOLUTION

A future version of Smart Array controller firmware will correct this issue.

As a workaround until the firmware is available, configure and present less than 64 LUNs from the MSA2040.

This advisory will be updated when additional information becomes available.



RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL: Proactive Updates Subscription Form

NAVIGATION TIP : For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the Navigation Tips document .

SEARCH TIP : For hints on locating similar documents on HP.com, refer to the Search Tips document


Hardware Platforms Affected: HPE MSA 2040 SAN Storage, HPE ProLiant XL730f Gen9 Server, HPE ProLiant DL160 Gen9 Server, HPE ProLiant DL180 Gen9 Server, HPE ProLiant DL360 Gen9 Server, HPE ProLiant BL460c Gen9 Server Blade, HPE ProLiant DL380 Gen9 Server, HPE Smart Array P244br Controller, HPE Smart Array P440 Controller, HPE Smart Array P440ar Controller, HPE Smart Array P441 Controller, HPE Smart Array P840 Controller, HPE H240 Smart Host Bus Adapter, HPE H240ar Smart Host Bus Adapter, HPE H241 Smart Host Bus Adapter, HPE H244br Smart Host Bus Adapter, HPE ProLiant XL230a Gen9 Server, HPE ProLiant XL250a Gen9 Server, HPE ProLiant DL120 Gen9 Server, HPE ProLiant ML150 Gen9 Server, HPE ProLiant DL60 Gen9 Server, HPE ProLiant DL80 Gen9 Server
Operating Systems Affected: Not Applicable
Software Affected: Not Applicable
Support Communication Cross Reference ID: IA04623059
©Copyright 2018 Hewlett Packard Enterprise Development LP
Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Provide feedback

Please rate the information on this page to help us improve our content. Thank you!
Document title: Advisory: HP Smart Array Gen9 Controllers - An HP Smart Array Gen9 Controller Stops Responding During Power-On Self-Test (POST) When Connected to a Modular Smart Array 2040 Presenting More Than 64 LUNs
Document ID: emr_na-c04623059-2
How helpful was this document?
How can we improve this document?
Note: Only English language comments can be accepted at this time.
Please wait while we process your request.