Advisory: HP Server Adapters - Multiple Issues May Occur When Network Partitioning Is Enabled On Qlogic NX2 Adapters On Servers In a Virtual Connect Environment

SUPPORT COMMUNICATION - CUSTOMER ADVISORY

Document ID: c04942515

Version: 1

Advisory: HP Server Adapters - Multiple Issues May Occur When Network Partitioning Is Enabled On Qlogic NX2 Adapters On Servers In a Virtual Connect Environment
NOTICE: The information in this document, including products and software versions, is current as of the Release Date. This document is subject to change without notice.

Release Date: 2016-01-14

Last Updated: 2016-01-14


DESCRIPTION

On an HP ProLiant server configured with Qlogic NX2 adapters, if the "Network Partitioning" (NPAR) feature is enabled in a Virtual Connect (VC) environment, multiple issues may occur where in some cases the ports may not show up in the System Configuration menu or at the Operating System level, or in other cases the connectivity of the ports may fluctuate at the Operating System level, depending upon whether a cold boot or warm boot was done previously.

The following example shows the missing ports in the System Configuration menu: Less than four ports per adapter are displayed with a VC profile assigned and NPAR enabled:

The following example shows the missing ports in the System Configuration menu with a VC profile un-assigned and NPAR enabled:

The following example shows the missing ports in OS: VC profile is assigned and NPAR is enabled:

The following example shows the missing ports in OS: VC profile is un-assigned and NPAR is enabled:

The following example shows the ports with NPAR configured shown as disconnected in the Operating System (VC profile assigned): The issue occurs after a cold boot/power cycle. Note that the disconnected ports have a factory default MAC address instead of the VC assigned MAC address.

The following example shows the ports with NPAR configured shown as connected in the Operating System (VC profile assigned): This issue occurs after a warm boot. Note that all the ports now have the VC assigned MAC address.

SCOPE

Any HP ProLiant server configured with any of the following HP Network Adapters using Qlogic NX2 UEFI driver 7.13.16(or earlier):

  • HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter
  • HP Flex-10 10Gb 2-port 530FLB Adapter
  • HP Flex-10 10Gb 2-port 530M Adapter
  • HP FlexFabric 10Gb 2-port 534FLB Adapter
  • HP FlexFabric 10Gb 2-port 534M Adapter
  • HP FlexFabric 20Gb 2-port 630FLB Adapter
  • HP FlexFabric 20Gb 2-port 630M Adapter
  • HP FlexFabric 10Gb 2-port 536FLB Adapter

RESOLUTION

As a temporary workaround, do not use the NPAR feature in a VC environment.

NOTE: Qlogic is currently investigating additional solutions. This advisory will be updated when additional information becomes available.





RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL: Proactive Updates Subscription Form .

NAVIGATION TIP : For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the Navigation Tips document .

SEARCH TIP : For hints on locating similar documents on HPE.com, refer to the Search Tips document .


Hardware Platforms Affected: HPE Ethernet 10Gb 2-port 530FLR-SFP+ Adapter, HPE Flex-10 10Gb 2-port 530FLB Adapter, HP Flex-10 10Gb 2-port 530M Adapter, HP FlexFabric 10Gb 2-port 534FLB Adapter, HPE FlexFabric 10Gb 2-port 534M Adapter, HPE FlexFabric 20Gb 2-port 630FLB Adapter, HPE FlexFabric 20Gb 2-port 630M Adapter, HPE FlexFabric 10Gb 2-port 536FLB Adapter
Operating Systems Affected: Not Applicable
Software Affected: Not Applicable
Support Communication Cross Reference ID: IA04942515
©Copyright 2018 Hewlett Packard Enterprise Development LP
Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Provide feedback

Please rate the information on this page to help us improve our content. Thank you!
Document title: Advisory: HP Server Adapters - Multiple Issues May Occur When Network Partitioning Is Enabled On Qlogic NX2 Adapters On Servers In a Virtual Connect Environment
Document ID: emr_na-c04942515-1
How helpful was this document?
How can we improve this document?
Note: Only English language comments can be accepted at this time.
Please wait while we process your request.