Print | Rate this content

CUSTOMER ADVISORY: HP MSA2000 G2 and P2000 G3 Modular Smart Arrays might have missing volumes seen from an operating system that does not support contiguous LUNs

SUPPORT COMMUNICATION - CUSTOMER ADVISORY

Document ID: c03470756

Version: REQUIRED FIELD INADVERTENTLY LEFT BLANK

CUSTOMER ADVISORY: HP MSA2000 G2 and P2000 G3 Modular Smart Arrays might have missing volumes seen from an operating system that does not support contiguous LUNs
NOTICE: The information in this document, including products and software versions, is current as of the Release Date. This document is subject to change without notice.

Release Date: 2012-08-28

Last Updated: 2012-09-07


DESCRIPTION

In some instances, a host may lose access to a LUN on an HP 2000 G2 Modular Smart Array (MSA) or an HP P2000 G3 MSA array. It has been seen that the LUN RESPONSE setting is not set correctly for operating systems that cannot handle contiguous LUNs.

The purpose of the LUN RESPONSE setting is to handle these situations by enabling the host drivers to continue probing the LUNs until they reach the LUN to which they have access to.

The option needs to be changed from NOT READY, which is the default option, to ILLEGAL REQUEST.

SCOPE

All HP MSA2000 G2 and P2000 G3 arrays are affected by this advisory. All protocols are affected.

Operating systems affected by this advisory include Linux, HP-UX, and VMware.

RESOLUTION

Change the LUN RESPONSE setting through the System Management Unit (SMU) or CLI using either controller A or B.

To change the LUN RESPONSE setting through the SMU:

  1. Shut down the host.

  2. Log into either the controller A or B SMU.

  3. In the View panel, right-click the system and select Configuration > Advanced Settings > Cache.

  4. Change the LUN response from NOT READY to ILLEGAL REQUEST.

  5. Click Apply.

  6. Restart the host.

To change the LUN RESPONSE setting through the CLI:

  1. Shut down the host.

  2. Log into either the controller A or B CLI.

  3. Once logged into the CLI, enter the following command:

    #set advanced-settings missing-lun-response illegal

  4. Restart the host.

For more information about changing the LUN RESPONSE setting, see the HP P2000 G3 MSA System SMU Reference Guide.

Proactive Updates

Receive support alerts (such as Customer Advisories), driver updates, software, firmware, and customer replaceable components, in your e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice Driver, Patch, Security, and Support alerts at the following URL: http://www.hp.com/go/myadvisory


Hardware Platforms Affected: HPE StorageWorks 2000fc G2 Modular Smart Array, HPE 2000sa G2 Modular Smart Array, HPE 2000i G2 Modular Smart Array, HPE P2000 G3 MSA Array Systems
Components Affected: Not Applicable
Operating Systems Affected: Not Applicable
Software Affected: Not Applicable
Third Party Products Affected: Not Applicable
Support Communication Cross Reference ID: IA03470756
©Copyright 2018 Hewlett Packard Enterprise Development LP
Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Provide feedback

Please rate the information on this page to help us improve our content. Thank you!
Document title: CUSTOMER ADVISORY: HP MSA2000 G2 and P2000 G3 Modular Smart Arrays might have missing volumes seen from an operating system that does not support contiguous LUNs
Document ID: emr_na-c03470756-2
How helpful was this document?
How can we improve this document?
Note: Only English language comments can be accepted at this time.