Print | Rate this content

Advisory: (Revision) ProLiant DL180 G5 & DL185 G5 Server: FIRMWARE UPGRADE REQUIRED - Server Configured With 12 Bay Drive Expander Backplane May Incorrectly Indicate Additional False Drive Failures for a Single Drive Failure in the Array

SUPPORT COMMUNICATION - CUSTOMER ADVISORY

Document ID: c01938877

Version: 2

Advisory: (Revision) ProLiant DL180 G5 & DL185 G5 Server: FIRMWARE UPGRADE REQUIRED - Server Configured With 12 Bay Drive Expander Backplane May Incorrectly Indicate Additional False Drive Failures for a Single Drive Failure in the Array
NOTICE: The information in this document, including products and software versions, is current as of the Release Date. This document is subject to change without notice.

Release Date: 2009-11-18

Last Updated: 2010-06-08


DESCRIPTION

Document Version
Release Date
Details
2
06/08/2010
Updated Resolution section with further clarification/instructions
1
11/19/2009
Original document release
IMPORTANT: This firmware upgrade is considered a critical fix and is required to prevent the issue detailed below. HP strongly recommends immediate application of this critical fix. Neglecting to perform the required action could result in the system falsely marking additional drives in the array as failed in an instance when only a single drive has failed. By disregarding this notification, the customer accepts the risk of incurring future related errors.

On rare occasions, a ProLiant DL180 G5 or DL185 G5 server configured with a 12 Bay Drive Expander Backplane may incorrectly mark additional drives in the array as failed, when encountering a single drive failure. The additional drives in the array being falsely marked as failed will function normally on a server reboot.

Any ProLiant DL180 G5 server configured as follows:

  • 12 Bay Drive Expander Backplane running a firmware version prior to version 2.02
  • SATA hard drives
  • Smart Array P400 Controller or Smart Array P800 Controller

Any ProLiant DL185 G5 server configured as follows:

  • 12 Bay Drive Expander Backplane running a firmware version prior to version 2.02
  • SATA hard drives
  • Smart Array P400 Controller or Smart Array P800 Controller

SCOPE

Any ProLiant DL180 G5 server configured as follows:

  • 12 Bay Drive Expander Backplane running a firmware version prior to version 2.02
  • SATA hard drives
  • Smart Array P400 Controller or Smart Array P800 Controller

Any ProLiant DL185 G5 server configured as follows:

  • 12 Bay Drive Expander Backplane running a firmware version prior to version 2.02
  • SATA hard drives
  • Smart Array P400 Controller or Smart Array P800 Controller

RESOLUTION

The Smart Component CP011998.scexe includes the 12 Bay Expander Backplane Firmware Version 2.02 and is now available for download. The 12 Bay Expander Backplane Firmware Version 2.02 will ensure that failure of a single drive does not initiate additional false drive failures within the array.

Perform the steps given below (in order) to upgrade the 12 Bay Expander Backplane Firmware to version 2.02.

Note: The P400/P800 Smart Array Firmware version needs to be at 6.86 (or higher) and the P410/P212 Firmware version needs to be at 2.50 (or higher).

Step 1

To ensure that the current firmware version for the 12 Bay Expander Backplane is prior to version 2.02, perform the following in the Array Diagnostic Utility (ADU):

  1. Run the ADU report.
  2. Save the report as a Zip file.
  3. Open the ADUreport.txt.
  4. Perform a search by using the search string:HP14HDD.

Locate the Product Revision, also known as the Firmware Version, under Product ID HP14HDD as follows:

Smart Array P400 in slot 5 : Storage Enclosure 1 : Sense Bus Parameters
Peripheral Type 0x0d
RMB 0x00
Versions 0x05
Misc 0x02
Additional Length 0x5b
Support Bits 0x00
Vendor ID HP
Product ID HP14HDD
Product Revision 2.00

Step 2

If the current firmware version of the 12 Bay Expander Backplane is prior to version 2.02, create a bootable USB key using the USB Key Utility for the Easy Set-Up CD as follows:

  1. Download the Easy Set-Up CD from:

    https://downloads.hpe.com/pub/softlib2/software1/cd/p2109415680/v55030/516359-023.zip

  2. Ensure the Easy Setup CD is inserted into an alternate computing device (server or PC running a Windows operating system).

  3. Download the HP USB Key Utility from:

    https://downloads.hpe.com/pub/softlib2/software1/sc-windows/p1576607567/v51924/cp010431.exe

  4. Follow the installation instructions for the HP USB Key Utility to create a bootable USB key from the Easy Set-UP CD.

Step 3

Perform the following to download the Smart Component CP011998.scexe (that includes the 12 Bay Expander Backplane Firmware Version 2.02) onto the USB key:

  1. Select the following ftp URL:

    https://downloads.hpe.com/pub/softlib2/software1/sc-linux-fw-array/p1883464895/v57700/CP011998.scexe

  2. Copy the CP011998.scexe to the files directory located on the USB key.

Step 4

Perform the following to upgrade the 12 Bay Expander Backplane Firmware to Version 2.02 on a ProLiant DL180 G5 or ProLiant DL185 G5 server running Windows Server or Linux operating systems:

  1. Insert the USB key into the ProLiant DL180 G5 or ProLiant DL185 G5 server.
  2. Boot the server using the Easy Setup CD Graphical User Interface (GUI) via the USB key.
  3. Type and hold CTRL+ALT while typing"d" ,"b", "x", in order to execute from the bash prompt.
  4. Type the following commands to execute ./CP011998.scexe from the bash prompt:

    # cd /mnt/boot/files

    # ./CP011998.scexe

  5. Follow the instructions on the screen in order to upgrade the 12 Bay Drive Expander Backplane Firmware to version 2.02.
RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:


NAVIGATION TIP : For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the Navigation Tips document .
SEARCH TIP : For hints on locating similar documents on HP.com, refer to the Search Tips document .

Hardware Platforms Affected: HPE Smart Array P800 Controller, HPE Smart Array P400 Controller, HPE ProLiant DL185 G5 Server, HPE ProLiant DL180 G5 Server
Operating Systems Affected: Not Applicable
Software Affected: Not Applicable
Support Communication Cross Reference ID: IA01938877
©Copyright 2018 Hewlett Packard Enterprise Development LP
Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Provide feedback

Please rate the information on this page to help us improve our content. Thank you!
Document title: Advisory: (Revision) ProLiant DL180 G5 & DL185 G5 Server: FIRMWARE UPGRADE REQUIRED - Server Configured With 12 Bay Drive Expander Backplane May Incorrectly Indicate Additional False Drive Failures for a Single Drive Failure in the Array
Document ID: emr_na-c01938877-3
How helpful was this document?
How can we improve this document?
Note: Only English language comments can be accepted at this time.